Finished developing TW Req'd on metrology frequency for OI UI loading

This commit is contained in:
Infineon\Ouellette 2025-01-10 13:59:31 -07:00
parent dd3aaad4a6
commit 63bded8bb1
3 changed files with 48 additions and 7 deletions

View File

@ -349,20 +349,31 @@ Event PUB_SIGN.CLICK()
Response = Dialog_Box('NDW_VERIFY_USER', @WINDOW, initParams)
Valid = Response<1>
If (Valid EQ True$) then
debug
if XLATE('APP_INFO', 'NEW_TW_SYSTEM_ACTIVE_SWITCH', 1, 'X') EQ True$ then
UsingTestWafers = Msg(@Window, '', 'YESNO', '', 'Log Test Wafer Usage':@FM:'Are any test wafers loaded?')
IsTWReqd = RDS_Services('IsTWLoggingReqd', RDSNo)
If UsingTestWafers then
TWLogResult = Dialog_Box('NDW_LOG_TEST_WAFER_USAGE', @Window, RDSNo : @VM : 'STANDARD' : @VM : 'REACTOR' : @VM : Reactor)
If TWLogResult then
QA_Services('SignLoadStage', RDSNo, @USER4, WfrQty, LLSide)
end else
ContinueLoad = Msg(@Window, '', 'YESNO', '', 'Continue?':@FM:'Test wafer logging was cancelled. Do you wish to continue signing?')
If ContinueLoad then
QA_Services('SignLoadStage', RDSNo, @USER4, WfrQty, LLSide)
If IsTWReqd then
Msg(@Window, 'Unable to sign load because test wafer logging is required on this run.')
end else
ContinueLoad = Msg(@Window, '', 'YESNO', '', 'Continue?':@FM:'Test wafer logging was cancelled. Do you wish to continue signing?')
If ContinueLoad then
QA_Services('SignLoadStage', RDSNo, @USER4, WfrQty, LLSide)
end
end
end
end else
QA_Services('SignLoadStage', RDSNo, @USER4, WfrQty, LLSide)
if IsTWReqd EQ False$ then
QA_Services('SignLoadStage', RDSNo, @USER4, WfrQty, LLSide)
end else
Msg(@Window, 'Unable to sign load because test wafer logging is required on this run.')
end
end
end else
QA_Services('SignLoadStage', RDSNo, @USER4, WfrQty, LLSide)
@ -704,3 +715,4 @@ return

View File

@ -117,7 +117,7 @@ Declare function Work_Order_Services, SRP_JSON, Logging_Services, Environment
Declare function Memberof, Obj_WO_Mat, Obj_WO_Mat_Log, SRP_Array, DateTime, Dialog_Box, obj_Prod_Spec
Declare function RDS_Services, RTI_DistinctList, GetTickCount, Clean_Insp_Services, WO_Mat_QA_Services
Declare function PSN_Services, Rds_Layer_Services, SRP_Rotate_Array, Qa_Services, SRP_Date, SRP_Time, SRP_Datetime
Declare function Reactor_Services, Signature_Services
Declare function Reactor_Services, Signature_Services, obj_rds, Test_Run_Services
LogPath = Environment_Services('GetApplicationRootPath') : '\LogFiles\RDS'
LogDate = Oconv(Date(), 'D4/')
@ -415,7 +415,6 @@ end service
// Rows are @FM delimted while columns are @VM delimited.
//----------------------------------------------------------------------------------------------------------------------
Service GetRDSData(WorkOrderNo, Columns, ShowGasGauge, RDSOverrideList)
RDSList = ''
If ( (WorkOrderNo NE '') or (RDSOverrideList NE '') ) then
@ -742,6 +741,23 @@ Service IsValidSubLot(RDSNo, RDSType, SupplierLot)
Response = IsValid
end service
Service IsTWLoggingReqd(RDSNo)
Response = False$
RDSRec = Database_Services('ReadDataRow', 'RDS', RDSNo, True$, 0, False$)
IsHGCVReqd = obj_RDS('MetPropFlag', RDSNo:@RM:RDSRec:@RM:'CRES')
If IsHGCVReqd NE True$ then
ExistingTWKeys = Test_Run_Services('GetTestRunKeysByRDS', RDSNo)
If ExistingTWKeys EQ '' then
Response = True$
end else
Response = False$
end
end else
Response = True$
end
end service
//----------------------------------------------------------------------------------------------------------------------
// VerifyEPPMetrology
//
@ -1638,3 +1654,4 @@ ClearCursors:
return

View File

@ -684,7 +684,18 @@ Service GetTestRunKeysByPSN(PSNo)
end service
Service GetTestRunKeysByRDS(RDSNo)
table = "TEST_RUN"
Open "DICT ":table To @DICT Else
Error_Services('Add', 'Error opening TEST_RUN dictionary')
End
If Error_Services('NoError') then
srch_strng = "RDS_ID":@VM:RDSNo:@FM
keylist = ""
option = ""
flag = ""
Btree.Extract(srch_strng, table, @DICT, keylist, option, flag)
Response = keylist
end
end service
Service GetTestRunWaferByID(TRWaferID)
@ -747,3 +758,4 @@ end service