# Restart IFX Hosted N Port
# Navigate to https://goto.infineon.com/ucportal and under SelfCP - Auto CF call EAF/EDA, Metrology Viewer, Infinity QS SPC number
From mestsa003.infineon.com(eaf-dev.mes.infineon.com) using your normal or MES account open the following application
"C:\Program Files\NPortAdminSuite\bin\npadmer.exe" if not found in start menu (NPort Administrator)
Select Port Monitor - Right click anywhere in the right pane - select load configuration com port - press go button from top ribbon
Look at entries starting with IP 10.95.192.\* for conn status not Connected and then
- Find entry with not connected under cond status
- Find matching EAF CI instance and verifying connection name "PCLDevice" with matching IP in connection settings example shown below
- Stop CI in EAF
- Using browser (Edge) navigate to http matching ip (this will bring up Moxa website like a home router) password is in shared KeePass
- Restart nPort device by using website
- Start EAF again
- If not on phone with user wait for data for about five minutes if nothing repeat one more time
- If still no data stop EAF like above
- Call lead and have them power cycle the nPort
- Start EAF and check for data in file share \\messv02ecc1.ec.local\EC_Characterization_Si\RawData base on folder date modified
![Alt Text](_Restart-IFX-hosted-nPort/image-1.png)
![Alt Text](_Restart-IFX-hosted-nPort/image-2.png)
![Alt Text](_Restart-IFX-hosted-nPort/image-3.png)