open-insight/LSL2/STPROC/NDW_MANUAL_WAFER_COUNT_EVENTS.txt
2024-10-31 14:22:20 -07:00

150 lines
5.6 KiB
Plaintext

Compile function NDW_MANUAL_WAFER_COUNT_EVENTS(CtrlEntId, Event, @PARAMS)
/***********************************************************************************************************************
This program is proprietary and is not to be used by or disclosed to others, nor is it to be copied without written
permission from Infineon.
Name : NDW_Manual_Wafer_Count_Events
Description : This function acts as a commuter module for all events related to this window.
Notes : Commuter Modules are automatically called from the Promoted_Events function which is called by the
application-specific promoted event handler. This makes it possible to add QuickEvents that need to
execute Basic+ logic without having use the Form Designer to make the association, although this is
limited to the events which are currently promoted.
If the form needs to call the commuter module directly then the QuickEvent parameters should be
formatted like this:
'@SELF','@EVENT',['@PARAM1','@PARAMx']
Parameters :
CtrlEntId [in] -- The fully qualified name of the control calling the promoted event
Event [in] -- The event being executed. See the Notes section regarding "PRE" events
Param1-15 [in] -- Additional event parameter holders
EventFlow [out] -- Set to 1 or 0 so the calling event knows whether or not to chain forward. See comments in
EVENT_SETUP insert
History : (Date, Initials, Notes)
04/12/24 djs Created initial commuter module.
***********************************************************************************************************************/
#pragma precomp SRP_PreCompiler
#window NDW_MANUAL_WAFER_COUNT
$Insert EVENT_SETUP
$Insert APP_INSERTS
$Insert MSG_EQUATES
Equ MSG_WIDTH$ to 650
Equ Comma$ to ','
Declare function Environment_Services, Logging_Services, Datetime
Declare subroutine Set_Property, Logging_Services, PlaceDialog
LogPath = Environment_Services('GetApplicationRootPath') : '\LogFiles\WaferCounter'
LogDate = Oconv(Date(), 'D4/')
LogTime = Oconv(Time(), 'MTS')
LogFileName = LogDate[7, 4] : '-' : LogDate[1, 2] : '-' : LogDate[4, 2] : ' Wafer Counter Verify Log.csv'
Headers = 'Logging DTM':@FM:'Logging Text'
objLog = Logging_Services('NewLog', LogPath, LogFileName, CRLF$, Comma$, Headers, '', False$, False$)
LoggingDTM = LogDate : ' ' : LogTime ; // Logging DTM
// Update the arguments so that the OpenInsight OLE event will treate the ActiveX event as a native event handler.
If Event EQ 'OLE' then
Transfer Event to OIEvent
Transfer Param1 to Event
Transfer Param2 to Param1
Transfer Param3 to Param2
Transfer Param4 to Param3
Transfer Param5 to Param4
Transfer Param6 to Param5
Transfer Param7 to Param6
Transfer Param8 to Param7
end
GoToEvent Event for CtrlEntID
Return EventFlow else EVENT_CONTINUE$
//-----------------------------------------------------------------------------
// EVENT HANDLERS
//-----------------------------------------------------------------------------
Event WINDOW.CREATE(CreateParam)
If CreateParam NE '' then
Set_Property(@Window, '@EXPECTED_QTY', CreateParam)
List = ''
For SlotIndex = 0 to 25
List<SlotIndex + 1> = SlotIndex
Next SlotIndex
Set_Property(@Window:'.CBO_WAFER_COUNT', 'LIST', List)
PlaceDialog(-2, -2)
end else
ErrorMsg = 'Wafer counter error. Null expected quantity passed in.'
LogData = ''
LogData<1> = OConv(Datetime(), 'DT2/^H')
LogData<2> = @User4
LogData<3> = ErrorMsg
Logging_Services('AppendLog', objLog, LogData, @RM, @FM)
MsgStruct = ''
MsgStruct<MTEXTWIDTH$> = MSG_WIDTH$
Msg(@Window, MsgStruct, 'PROCESS_ERROR', '', ErrorMsg)
End_Dialog(@Window, '')
end
End Event
Event CBO_WAFER_COUNT.CHANGED(NewData)
Set_Property(@Window:'.PUB_OK', 'ENABLED', (NewData NE '') )
end event
Event PUB_OK.CLICK()
ExpectedQty = Get_Property(@Window, '@EXPECTED_QTY')
WaferCount = Get_Property(@Window:'.CBO_WAFER_COUNT', 'TEXT')
If ExpectedQty EQ WaferCount then
LogData = ''
LogData<1> = OConv(Datetime(), 'DT2/^H')
LogData<2> = @User4
LogData<3> = 'Expected quantity equals entered quantity. Proceeding...'
Logging_Services('AppendLog', objLog, LogData, @RM, @FM)
End_Dialog(@Window, WaferCount)
end else
ErrorMsg = 'Wafer counter error. Expected quantity "':ExpectedQty:'" does not match entered quantity "':WaferCount:'".'
LogData = ''
LogData<1> = OConv(Datetime(), 'DT2/^H')
LogData<2> = @User4
LogData<3> = ErrorMsg
Logging_Services('AppendLog', objLog, LogData, @RM, @FM)
MsgStruct = ''
MsgStruct<MTEXTWIDTH$> = MSG_WIDTH$
Msg(@Window, MsgStruct, 'PROCESS_ERROR', '', ErrorMsg)
end
end event
Event PUB_CANCEL.CLICK()
LogData = ''
LogData<1> = OConv(Datetime(), 'DT2/^H')
LogData<2> = @User4
LogData<3> = 'Manual verification process canceled'
Logging_Services('AppendLog', objLog, LogData, @RM, @FM)
End_Dialog(@Window, '')
end event