open-insight/LSL2/OIEVENT/READ/LAST_WFR_CI_GROUP..json
2024-03-25 15:12:53 -07:00

11 lines
3.3 KiB
JSON

{
"header": {
"version": 1,
"type": "record"
},
"body": {
"record1": {
"<1>": "declare subroutine forward_event, security_err_msg, Comm_RDS\r\ndeclare function company_comm, msg, security_check, post_event, rowexists\r\ndeclare function fieldcount, scroll_enable, rds_comm, rds_comm2, memberof\r\n$insert logical\r\n$insert security_rights_equ\r\n$insert rds_equ\r\n$insert msg_equates\r\n$insert prod_spec_equ\r\n$insert quote_spec_equ\r\n\r\nNewRecord = false$\r\nif rowexists( 'RDS', .rds_no->text ) then\r\n ReadOk = true$\r\nend else\r\n * user is trying to add new don't allow ( only create via schedule )\r\n MsgInfo = ''\r\n MsgInfo<mtext$> = 'Last Wafer - You can only create run data sheets from schedule.'\r\n MsgInfo<micon$> = 'H'\r\n Void = msg( '', MsgInfo )\t \r\n ReadOk = false$\r\n .rds_no->text = ''\r\n Void = post_event( CtrlEntId, 'CLEAR', False$, True$ )\r\nend\r\nif ReadOk then\r\n if get_property( @window, '@NoRead' ) then\r\n Void = set_property( @window, '@NoRead', 0 )\r\n end else\r\n * no qbf active do the read\r\n * if it is active the read already took place\r\n forward_event()\r\n end\r\n Void = set_property( @window, '@TotRej', ((.cust_rej_tot->text ) + (.lsl_rej_tot->text)) ) \r\n Void = set_property( @window, '@NCRMustSave', false$ )\r\n RejAcct = .reject_info->array\r\n Void = set_property( @window, '@OrigRejAcct', RejAcct ) \r\n RdsNo = .rds_no->text\r\n .thick_all_label->text = xlate( 'RDS', RdsNo, 'THICK_MIN_TAR_MAX', 'X' )\r\n .res_all_label->text = xlate( 'RDS', RdsNo, 'RES_MIN_TAR_MAX', 'X' )\r\n .con_all_label->text = xlate( 'RDS', RdsNo, 'CON_MIN_TAR_MAX', 'X' ) \r\n TMod = .mod_info->array\r\n InMod = Tmod<1>\r\n TMod<2> = oconv( InMod, '[XLATE_CONV,LSL_USERS*FIRST_LAST]' )\r\n .mod_info->array = TMod\r\n DisFields = 'REACTOR/LOT_NUM/QUOTE_NO/CUST_INFO/STATUS/PO_WO_PARTNUM/LOT_NUM_VERIFY/' \r\n DisFields:= 'RUN_ORDER_NUM/WAFERS_SCHEDULED/OP_OUT/OP_OUT_NAME/UNLOAD_BUTTON/WAFERS_IN/'\r\n DisFields:= 'OP_OUT_DATE/OP_OUT_TIME/LSL_REJ_TOT/CUST_REJ_TOT/PSN'\r\n swap '/' with @rm:@window:'.' in DisFields\r\n DisFields = @window:'.':DisFields\r\n void = set_property( DisFields, 'ENABLED', 0 )\r\n if memberof( @user4, 'ENGINEERING' ) or memberof( @user4, 'MASTER' ) then\r\n .srpcfg_button->visible = 1 \r\n end else\r\n .srpcfg_button->visible = 0\r\n end\r\n if NewRecord else\r\n\t if security_check( 'RDS', Edit$ ) else\r\n\t * protect all fields\r\n\t AllControls = utility( 'OBJECTLIST', @window, '' )\r\n\t Acnt = fieldcount( AllControls, @fm ) \r\n\t for i = 1 to Acnt \r\n\t ThisControl = AllControls<i>\r\n\t if ThisControl[-6,6] = '_LABEL' or index( ThisControl, 'MENU', 1 ) or index( ThisControl, 'TEXT', 1 ) else\r\n\t void = set_property( ThisControl, 'ENABLED', 0 )\r\n\t end \r\n\t next i \r\n Void = scroll_enable()\t \t \r\n\t end\r\n end\r\n Void = rds_comm2('SET_SRP_PROFILE') \r\n Void = rds_comm( \"READ_STORE\" )\r\n Void = rds_comm2( \"HOLD_CHECK\" )\r\n Void = rds_comm2( \"SUPPL_CHECK\" ) \r\n \r\n Comm_RDS('Refresh') ;* Added 09/23/2004 JCH\r\nend\r\nreturn 0 "
}
}
}