open-insight/LSL2/STPROC/RUN_STATUS_CONV.txt
Infineon\StieberD 7762b129af pre cutover push
2024-09-04 20:33:41 -07:00

46 lines
1.2 KiB
Plaintext

SUBROUTINE RUN_STATUS_CONV(ConvType, DataIo, SubrLabel, ReturnedValue)
$INSERT LOGICAL
EQU VALID$ to 0 ;* successful
EQU INVALID_MSG$ to 1 ;* bad data - print error message window
EQU INVALID_CONV$ to 2 ;* bad conversion - " "
EQU INVALID_NOMSG$ to 3 ;* bad but do not print the error message window
Status() = Valid$
BEGIN CASE
CASE ConvType = 'ICONV'
Vals = XLATE('SYSREPOSPOPUPS','LSL2**RUN_STATUS',8,'X')
Desc = ''
LOOP
Val = Vals[1,@VM]
Code = Val[1,@SVM]
Desc = Val[COL2()+1,@SVM]
UNTIL Desc = DataIO OR Vals = ''
Vals = DELETE(Vals,1,1,0)
REPEAT
ReturnedValue = Code
CASE ConvType = 'OCONV'
Vals = XLATE('SYSREPOSPOPUPS','LSL2**RUN_STATUS',8,'X')
Desc = ''
LOOP
Val = Vals[1,@VM]
Code = Val[1,@SVM]
Desc = Val[COL2()+1,@SVM]
UNTIL Code = DataIO OR Vals = ''
Vals = DELETE(Vals,1,1,0)
REPEAT
IF Desc = '' THEN Desc = DataIO
ReturnedValue = Desc
CASE OTHERWISE$
Status() = invalid_msg$
END CASE
RETURN