open-insight/LSL2/STPROC/FIX_MFC.txt
Infineon\StieberD 7762b129af pre cutover push
2024-09-04 20:33:41 -07:00

50 lines
729 B
Plaintext

COMPILE ROUTINE FIX_MFC(Dummy)
ROWDEF(CHARSTR)
DECLARE SUBROUTINE obj_Schedule,Send_Dyn,Send_Info
DECLARE FUNCTION Get_Status, Set_Printer
$INSERT MFC_EQUATES
OPEN 'MFC' To FileIn ELSE
DEBUG
GOTO Bail
END
Select FileIn
Done = 0
RecCnt = 0
LOOP
READNEXT MFCKey ELSE Done = 1
UNTIL Done
READ MFCRec FROM FileIn,MFCKey THEN
WriteFlag = 0
IF MFCRec<MFC_ASM_PN$> = '54-117817A02' THEN
IF MFCRec<MFC_OUTLET_PRESS$> NE 'ATM' THEN
RecCnt += 1
MFCRec<MFC_OUTLET_PRESS$> = 'ATM'
WRITE MFCRec ON FileIn,MFCKey THEN
Send_Dyn(RecCnt:' ':MFCKey)
END
END
END
END
REPEAT
IF Get_Status(errCode) THEN DEBUG
* * * * * * *
Bail:
* * * * * * *