open-insight/LSL2/STPROC/COMM_WO_PROD_EPI.txt
Infineon\StieberD 24a246a99b added logic to RDS_ACTIONS to restore load signatures if erased unexpectedly
refactored solution to leverage the LOT and LOT_EVENT tables

minor fix
2024-11-05 17:51:13 -07:00

1021 lines
30 KiB
Plaintext

COMPILE FUNCTION Comm_WO_Prod_EPI(Instruction, Parm1,Parm2)
/*
Commuter module for WO_Prod_EPI, Read Only WO Step window for production use (Work Order Step) Work Order step table
11/11/2004 - John C. Henry, J.C. Henry & Co., Inc.
03/20/2019 - DJS - Updated "CreateRDS" subroutine to use Work_Order_Services instead of obj_WO_LOG to avoid
locking WO_LOG database table unnecessarily.
*/
DECLARE SUBROUTINE Set_Property, Set_Status, ErrMsg, Set_Property, obj_AppWindow, obj_Notes, obj_WM_Out
DECLARE SUBROUTINE Error_Services, obj_Post_Log, obj_SAP, Print_Control_Plan, Send_Info, ShowWindow
DECLARE SUBROUTINE Btree.Extract, Send_Event, Security_Err_Msg, Forward_Event, End_Window, Start_Window
DECLARE FUNCTION Get_Property, Get_Status, Popup, Send_Message, Msg, Security_Check, Dialog_Box, RowExists
DECLARE FUNCTION Dialog_Box, obj_WO_Log, obj_RDS, obj_WM_Out,obj_React_Run, Set_Property, MemberOf
DECLARE FUNCTION Work_Order_Services, Error_Services
$INSERT POPUP_EQUATES
$INSERT LOGICAL
$INSERT MSG_EQUATES
$INSERT APPCOLORS
$INSERT WO_LOG_EQUATES
$INSERT WO_STEP_EQU
$INSERT WO_MAT_EQUATES
$INSERT WM_OUT_EQUATES
$INSERT ORDER_EQU
$INSERT ORDER_DET_EQU
$INSERT QUOTE_SPEC_EQU
$INSERT PROD_SPEC_EQUATES
$INSERT PRS_STAGE_EQUATES
$INSERT EPI_PART_EQUATES
$INSERT LSL_USERS_EQU
$INSERT SECURITY_RIGHTS_EQU
$INSERT QUOTE_SIGS_EQU
$INSERT RTI_STYLE_EQUATES
Equ HIDE$ To 0
Equ NORMAL$ To 1
Equ MINIMIZE$ To 2
Equ MAXIMIZE$ To 3
EQU CRLF$ TO \0D0A\
EQU COL$ADD_DESC TO 1
EQU COL$ADD_AMT TO 2
EQU COL$WM_IN_CASS_NO TO 1
EQU COL$WM_IN_BLANK TO 2
EQU COL$WM_IN_QTY TO 3
EQU COL$WM_IN_REJ TO 4
EQU COL$WM_IN_REMAINING TO 5
EQU COL$WM_IN_STATUS TO 6
EQU COL$RUN_NO TO 1
EQU COL$RDS_NO TO 2
EQU COL$REACTOR TO 3
EQU COL$ZONE1 TO 4
EQU COL$ZONE2 TO 5
EQU COL$SCHED TO 6
EQU COL$PTEST TO 7
EQU COL$UNLOAD TO 8
EQU COL$RDS_STATUS TO 9
EQU COL$WM_OUT_STATUS TO 8
ErrTitle = 'Error in Comm_WO_Log'
ErrorMsg = ''
Result = ''
If Get_Property('NDW_MAIN', 'VISIBLE') then
AppMain = 'NDW_MAIN'
end else
AppMain = 'LSL_MAIN2'
end
BEGIN CASE
CASE Instruction = 'Create' ; GOSUB Create
CASE Instruction = 'Refresh' ; GOSUB Refresh
CASE Instruction = 'Page' ; GOSUB Page
CASE Instruction = 'Read' ; GOSUB Read
CASE Instruction = 'Write' ; GOSUB Write
CASE Instruction = 'Clear' ; GOSUB Clear
CASE Instruction = 'Delete' ; GOSUB Delete
CASE Instruction = 'Close' ; GOSUB Close
CASE Instruction = 'GotFocus' ; GOSUB GotFocus
CASE Instruction = 'WONoLF' ; GOSUB WONoLF
CASE Instruction = 'StepGF' ; GOSUB StepGF
CASE Instruction = 'OpenWOS' ; GOSUB OpenWOS
CASE Instruction = 'ViewProdSpec' ; GOSUB ViewProdSpec
CASE Instruction = 'RdsDC' ; GOSUB RdsDC
CASE Instruction = 'LUWONo' ; GOSUB LUWONo
CASE Instruction = 'BrowseRDS' ; GOSUB BrowseRDS
CASE Instruction = 'WMInDC' ; GOSUB WMInDC
CASE Instruction = 'WMOutDC' ; GOSUB WMOutDC
CASE Instruction = 'CreateRDS' ; GOSUB CreateRDS
CASE Instruction = 'ViewPSN' ; GOSUB ViewPSN
CASE Instruction = 'RemWMOut' ; GOSUB RemWMOut
CASE Instruction = 'WaferTrace' ; GOSUB WaferTrace
CASE Instruction = 'ControlPlanClick' ; GOSUB ControlPlanClick
CASE 1
ErrorMsg = 'Unknown Instruction passed to routine'
END CASE
RETURN Result
* * * * * * *
Create:
* * * * * * *
obj_Appwindow('Create',@WINDOW)
QuoteSigs = XLATE( 'CONFIG', 'QUOTE_SIGS','', 'X' )
IF @USER4 = QuoteSigs<ProdCtrlMgr$> OR MemberOf(@USER4, 'OI_SUPERUSER') THEN
Set_Property(@WINDOW:'.REM_CASSETTES','VISIBLE',1)
Set_Property(@WINDOW:'.REM_WM_OUT','VISIBLE',1)
END ELSE
Set_Property(@WINDOW:'.REM_CASSETTES','VISIBLE',0)
Set_Property(@WINDOW:'.REM_WM_OUT','VISIBLE',0)
END
GOSUB Refresh
RETURN
* * * * * * *
Read:
* * * * * * *
WONo = Get_Property(@WINDOW:'.WO_NO','TEXT')
IF RowExists('WO_LOG',WONo) ELSE
ErrMsg('Incorrect Work Order Number entered.')
Send_Event(@WINDOW,'CLEAR')
RETURN
END
GOSUB Refresh
RETURN
* * * * * * *
Write:
* * * * * * *
RETURN
* * * * * * *
Clear:
* * * * * * *
Send_Event(@WINDOW,'PAGE',1)
GOTO Refresh
RETURN
* * * * * * *
Delete:
* * * * * * *
RETURN
* * * * * * *
Page:
* * * * * * *
obj_Appwindow('Page')
GOSUB Refresh
RETURN
* * * * * * *
Close:
* * * * * * *
obj_Appwindow('DetailReturn')
RETURN
* * * * * * *
GotFocus:
* * * * * * *
WOStepKey = Get_Property(@WINDOW,'@RETURN_FROM_RDS')
IF WOStepKey NE '' THEN
Set_Property(@WINDOW,'@RETURN_FROM_RDS','')
Send_Event(@WINDOW,'READ')
END
RETURN
* * * * * * *
WONoLF:
* * * * * * *
DataValue = Get_Property(@WINDOW:'.WO_NO','TEXT')
If DataValue = '' Then RETURN
IF INDEX(DataValue,'.',1) THEN
* Try a BTREE lookup on PROD_ORD_NO
OPEN 'DICT.WO_LOG' TO DictVar ELSE
ErrMsg('Unable to open "DICT.WO_LOG" for index lookup in COMM_SHIPMENT routine.')
RETURN
END
SearchString = 'PROD_ORD_NO':@VM:DataValue:@FM
WONos = ''
Flag = ''
Btree.Extract(SearchString, 'WO_LOG', DictVar, WONos, '', Flag)
errCode = ''
IF Get_Status(errCode) THEN
ErrMsg(errCode)
RETURN
END
IF WONos = '' THEN
ErrMsg('Value Entered "':DataValue:'" is not found.')
Result = 0
RETURN
END
IF INDEX(WONos,@VM,1) THEN
* This is an error
ErrMsg('Multiple Work Orders ':QUOTE(DataValue):' for Prod Order entered.')
Result = 0
RETURN
END ELSE
Set_Property(@WINDOW:'.WO_NO','DEFPROP',WONos)
END
Result = 1
END ELSE
IF RowExists('WO_LOG', DataValue) THEN
Result = 1
END ELSE
Message = QUOTE(DataValue):' is not a valid WO No'
ErrMsg(Message)
Set_Property(@WINDOW:'.WO_NO','DEFPROP','')
Result = 0
END
END
RETURN
* * * * * * *
Refresh:
* * * * * * *
PSStatus = Get_Property(@WINDOW:'.PS_STATUS','TEXT')
IF PSStatus = 'Active' THEN
Set_Property(@WINDOW:'.PS_STATUS','BACKCOLOR',GREEN$)
END ELSE
Set_Property(@WINDOW:'.PS_STATUS','BACKCOLOR',RED$)
END
* WM_IN background colors
CtrlName = @WINDOW:'.WM_IN'
WMInArray = Get_Property(CtrlName,'INVALUE')
WMInStatuses = WMInArray<COL$WM_IN_STATUS>
FOR I = 1 TO COUNT(WMInStatuses,@VM) + (WMInStatuses NE '')
WMInStatus = WMInStatuses<1,I>
BEGIN CASE
CASE WMInStatus = 'Ready to Build' ; LineColor = RCV_BLUE$
CASE WMInStatus = 'Building' ; LineColor = PRE_BLUE$
CASE WMInStatus = 'Cond Post Clean' ; LineColor = INP_BLUE$
CASE WMInStatus = 'Ready to Post Clean' ; LineColor = INP_BLUE$
CASE WMInStatus = 'Ready for QA' ; LineColor = POS_BLUE$
CASE WMInStatus = 'Ready to Use' ; LineColor = GREEN$
CASE WMInStatus = 'Ready to Ship' ; LineColor = GREEN$
CASE WMInStatus = 'Shipped' ; LineColor = LTGREY$
CASE WMInStatus = 'Empty' ; LineColor = LTGREY$
CASE WMInStatus = 'On Hold' ; LineColor = RED$
CASE WMInStatus = 'Open NCR' ; LineColor = RED$
CASE WMInStatus = 'Cassette Rejected' ; LineColor = ORANGE$
CASE 1 ; LineColor = WHITE$
END CASE
stat = Send_Message(CtrlName,'COLOR_BY_POS',0,I,LineColor)
NEXT I
* All cassette detail background colors
CtrlName = @WINDOW:'.RUNS'
CassArray = Get_Property(CtrlName,'ARRAY')
RdsStatuses = CassArray<COL$RDS_STATUS>
FOR I = 1 TO COUNT(RdsStatuses,@VM) + (RdsStatuses NE '')
RdsStatus = RdsStatuses<1,I>
a = RdsStatus[-1,8]
a1 = RdsStatus[-1,9]
BEGIN CASE
CASE RdsStatus[-3,3] = 'Run' ; LineColor = RCV_BLUE$ ;* Ready to Run
CASE RdsStatus[10,3] = 'Pre' ; LineColor = PRE_BLUE$ ;* xxx Pre Clean, Pre SurfaceInspect, Pre Surf Scan
CASE RdsStatus[10,4] = 'Load' ; LineColor = INP_BLUE$ ;* xxx Load
CASE RdsStatus[1,6] = 'Loaded' ; LineColor = GREEN$ ;* Loaded
CASE RdsStatus[-8,8] = 'Met Comp' ; LineColor = LTGREY$ ;* EpiPRO Unloaded
CASE RdsStatus[-9,9] = 'Needs Met' ; LineColor = YELLOW$ ;* EpiPro Unloaded Nees Metrology
CASE RdsStatus[1,7] = 'Post' ; LineColor = POS_BLUE$
CASE RdsStatus[1,3] = 'Epi' and RdsStatus[-6,6] = 'Loaded' ; LineColor = ORANGE$ ;* EpiPRO Test
CASE RdsStatus[1,3] = 'Epi' and RdsStatus[-8,8] = 'Unloaded' ; LineColor = LTORANGE$ ;* EpiPRO Test
CASE RdsStatus[10,2] = 'QA' ; LineColor = YELLOW$ ;* xxx QA
CASE RdsStatus[1,2] = 'QA' ; LineColor = LTGREY$ ;* QA Complete
CASE RdsStatus[1,4] = 'Canc' ; LineColor = LTGREY$
CASE RdsStatus[1,3] = 'Void' ; LineColor = LTGREY$
CASE RdsStatus[1,3] = 'Out' ; LineColor = RED$
CASE 1 ; LineColor = WHITE$
END CASE
stat = Send_Message(CtrlName,'COLOR_BY_POS',0,I,LineColor)
NEXT I
* WM_OUT background colors
CtrlName = @WINDOW:'.WM_OUT'
WMOutArray = Get_Property(CtrlName,'INVALUE')
WMOutStatuses = WMOutArray<COL$WM_OUT_STATUS>
FOR I = 1 TO COUNT(WMOutStatuses,@VM) + (WMOutStatuses NE '')
WMOutStatus = WMOutStatuses<1,I>
BEGIN CASE
CASE WMOutStatus = 'Ready to Build' ; LineColor = RCV_BLUE$
CASE WMOutStatus = 'Building' ; LineColor = PRE_BLUE$
CASE WMOutStatus = 'PostEpi Clean' ; LineColor = INP_BLUE$
CASE WMOutStatus = 'PostEpi Surfscan' ; LineColor = INP_BLUE$
CASE WMOutStatus = 'PostEpi Inspection' ; LineColor = POS_BLUE$
CASE WMOutStatus = 'Ready for QA' ; LineColor = POS_BLUE$
CASE WMOutStatus = 'Ready to Use' ; LineColor = MU_GREEN$
CASE WMOutStatus = 'QA Complete' ; LineColor = YELLOW$
CASE WMOutStatus = 'Ready to Ship' ; LineColor = GREEN$
CASE WMOutStatus = 'Shipped' ; LineColor = LTGREY$
CASE WMOutStatus = 'Empty' ; LineColor = LTGREY$
CASE WMOutStatus = 'Void' ; LineColor = GREY$
CASE WMOutStatus = 'On Hold' ; LineColor = RED$
CASE WMOutStatus = 'Open NCR' ; LineColor = RED$
CASE WMOutStatus = 'Cassette Rejected' ; LineColor = ORANGE$
CASE 1 ; LineColor = WHITE$
END CASE
stat = Send_Message(CtrlName,'COLOR_BY_POS',0,I,LineColor)
NEXT I
Ctrls = @WINDOW:'.TOT_ORD_ITEM_QTY':@RM ; Props = 'INVALUE':@RM
Ctrls := @WINDOW:'.TOT_PRE_EPI_REJ':@RM ; Props := 'INVALUE':@RM
Ctrls := @WINDOW:'.TOT_RDS_PROD_TEST':@RM ; Props := 'INVALUE':@RM
Ctrls := @WINDOW:'.TOT_WFRS_OUT':@RM ; Props := 'INVALUE':@RM
Ctrls := @WINDOW:'.TOT_MU_WFRS_OUT':@RM ; Props := 'INVALUE':@RM
Ctrls := @WINDOW:'.TOT_POST_EPI_REJ' ; Props := 'INVALUE'
Vals = Get_Property(Ctrls,Props)
OrdQty = Vals[1,@RM]
PreEpiRej = Vals[COL2()+1,@RM]
ProdTest = Vals[COL2()+1,@RM]
WfrsOut = Vals[COL2()+1,@RM]
MUWfrsOut = Vals[COL2()+1,@RM]
PostEpiRej = Vals[COL2()+1,@RM]
* This section re-written 11/22/2011 JCH
WONo = Get_Property(@WINDOW:'.WO_NO','DEFPROP')
StepNo = Get_Property(@WINDOW:'.PROC_STEP_NO','DEFPROP')
WOLogRec = XLATE('WO_LOG',WONo,'','X')
WOMatKeys = WOLogRec<WO_LOG_WO_MAT_KEY$>
WOWfrQty = SUM(XLATE('WO_MAT',WOMatKeys,WO_MAT_WAFER_QTY$,'X'))
WOOrderQty = XLATE('WO_LOG',WONo,'TOT_ORD_ITEM_QTY','X')
IF WOOrderQty = 0 THEN
WOOrderQty = XLATE('WO_LOG',WONo,'WO_QTY','X')
END
WOLoadCnt = SUM(XLATE('WO_MAT',WOMatKeys,'WMI_RDS_LOAD_CNT','X'))
WOPreEpiRej = SUM(XLATE('WO_MAT',WOMatKeys,'WM_IN_REJ_WFRS','X'))
RRunNos = XLATE('WO_STEP',WONo:'*':StepNo,6,'X')
WOUnloadCnt = SUM(XLATE('REACT_RUN',RRunNos,'EPI_PRO_UNLD_CNT','X'))
WOPTCnt = SUM(XLATE('REACT_RUN',RRunNos,'EPI_PRO_PT_CNT','X'))
IF WOLoadCnt > 0 THEN
OrdPcntComp = ICONV(((WOPreEpiRej + WOUnloadCnt + WOPTCnt)/WOOrderQty)*100,'MD0')
WipPcntComp = ICONV(((WOPreEpiRej + WOUnloadCnt + WOPTCnt)/WOWfrQty)*100,'MD0')
END ELSE
OrdPcntComp = 0
WipPcntComp = 0
END
OrdPcntComp = 'Order - ':OCONV(OrdPcntComp,'MD0S%')
WipPcntComp = 'WIP - ':OCONV(WipPcntComp,'MD0S%')
Set_Property(@WINDOW:'.ORDER_PCNT','DEFPROP',OrdPcntComp)
Set_Property(@WINDOW:'.WIP_PCNT','DEFPROP',WipPcntComp)
* SAP interface update
IF WONo NE '' THEN
IF WOLogRec<WO_LOG_WO_START_DTM$> = '' OR WOLogRec<WO_LOG_WO_STOP_DTM$> = '' THEN
CurrDTM = ICONV(OCONV(Date(),'D4/'):' ':OCONV(Time(),'MTH') ,'DT')
ProdOrderNo = WOLogRec<WO_LOG_PROD_ORD_NO$>
IF ProdOrderNo NE '' THEN
IF WOLoadCnt >= 1 AND WOLogRec<WO_LOG_WO_START_DTM$> = '' THEN
obj_Post_Log('Create','WO_LOG':@RM:WONo:@RM:WO_LOG_WO_START_DTM$:@RM:CurrDTM)
END
IF (WOPreEpiRej + WOUnloadCnt + WOPTCnt) >= WOOrderQty AND WOLogRec<WO_LOG_WO_STOP_DTM$> = '' THEN
obj_Post_Log('Create','WO_LOG':@RM:WONo:@RM:WO_LOG_WO_STOP_DTM$:@RM:CurrDTM)
END
END
END ;* End of check for WO_START and WO_STOP DTM's in WO Log record
END
* End of rewrite JCH
* QBF buttons
Ctrls = @WINDOW:'.QBF_FIRST_FIX':@RM ; Props = 'ENABLED':@RM
Ctrls := @WINDOW:'.QBF_PREV_FIX':@RM ; Props := 'ENABLED':@RM
Ctrls := @WINDOW:'.QBF_ABS_FIX':@RM ; Props := 'ENABLED':@RM
Ctrls := @WINDOW:'.QBF_NEXT_FIX':@RM ; Props := 'ENABLED':@RM
Ctrls := @WINDOW:'.QBF_LAST_FIX':@RM ; Props := 'ENABLED':@RM
Ctrls := @WINDOW:'.QBF_STOP_FIX' ; Props := 'ENABLED'
IF Get_Property(@WINDOW,'QBFLIST') = '' THEN
Vals = 0:@RM:0:@RM:0:@RM:0:@RM:0:@RM:0
END ELSE
Vals = 1:@RM:1:@RM:1:@RM:1:@RM:1:@RM:1
END
Set_Property(Ctrls,Props,Vals)
* Turn edit table symbolic column backgrounds to green
ETSymbolics = Get_Property(@WINDOW,'@ET_SYMBOLICS') ;* Loaded during 'Create' in obj_Appwindow
ETCtrls = ETSymbolics<1>
ETCols = ETSymbolics<2>
FOR I = 1 TO COUNT(ETCtrls,@VM) + (ETCtrls NE '')
ETCtrl = ETCtrls<1,I>
IF ETCtrl NE @WINDOW:'.RUNS' AND ETCtrl NE @WINDOW:'.WM_OUT' AND ETCtrl NE @WINDOW:'.WM_IN' THEN
ETList = Get_Property(ETCtrl,'LIST')
FOR Line = 1 TO COUNT(ETList,@FM) + (ETList NE '')
IF ETList<Line,1> NE '' THEN
FOR N = 1 TO COUNT(ETCols<1,I>,@SVM) + (ETCols<1,I> NE '')
stat = Send_Message(ETCtrl,'COLOR_BY_POS',ETCols<1,I,N>,Line,GREEN$)
NEXT N
END
NEXT Line
END
NEXT I
hWnd = Get_Property(@WINDOW, "HANDLE")
ShowWindow(hWnd, NORMAL$)
RETURN
* * * * * * *
LUWONo:
* * * * * * *
Set_Status(0)
WOKeys = obj_WO_Log('Find')
IF Get_Status(errCode) THEN ErrMsg(ErrCode)
IF WOKeys NE '' THEN
TypeOver = ''
TypeOver<PDISPLAY$> = WOKeys
TypeOver<PMODE$> = 'K'
TypeOver<PSELECT$> = 1
WOKey = Popup(@WINDOW,TypeOver,'WO_LOG_QUERY')
IF Get_Status(errCode) THEN
ErrMsg(errCode)
END
IF WOKey NE '' THEN obj_Appwindow('LUValReturn',WOKey:@RM:@WINDOW:'.WO_NO':@RM:'') ;* Loads form key or QBFList as required
END
RETURN
* * * * * * *
StepGF:
* * * * * * *
WONo = Get_Property(@WINDOW:'.WO_NO','TEXT')
WOStep = Get_Property(@WINDOW:'.PROC_STEP_NO','TEXT')
IF WONo NE '' AND WOStep = '' THEN
WOStepKeys = XLATE('WO_LOG',WONo,WO_LOG_WO_STEP_KEY$,'X')
IF INDEX(WOStepKeys,@VM,1) THEN
LastStep = WOStepKeys[-1,'B':@VM]
WOStep = FIELD(LastStep,'*',2)
END ELSE
WOStep = FIELD(WOStepKeys,'*',2)
END
CurrControl = @WINDOW:'.PROC_STEP_NO'
CurrPos = ''
obj_Appwindow('LUValReturn',WOStep:@RM:CurrControl:@RM:CurrPos)
END
RETURN
* * * * * * *
ViewProdSpec:
* * * * * * *
PSNo = Get_Property(@WINDOW:'.PS_NO','TEXT')
IF PSNo = '' THEN RETURN
obj_AppWindow('ViewRelated','PROD_SPEC':@RM:PSNo)
Send_Event(@WINDOW:'.PS_NO','LOSTFOCUS') ;* Kicks the symbolics
RETURN
* * * * * * *
OpenWOS:
* * * * * * *
IF Get_Property(@WINDOW:'.WO_NO','TEXT') NE '' THEN
Send_Event(@WINDOW,'CLEAR')
END
OpenWONo = obj_WO_Log('OpenWONos','')
IF OpenWONo NE '' THEN
obj_AppWindow('LoadFormKeys',@WINDOW:@RM:OpenWONo)
END
RETURN
* * * * * * *
RdsDC:
* * * * * * *
CtrlEntID = @WINDOW:'.RUNS'
CurrPos = Get_Property(CtrlEntID,'SELPOS')
CurrCol = CurrPos<1>
CurrRow = CurrPos<2>
RDSNo = Get_Property(CtrlEntID,'CELLPOS',COL$RDS_NO:@FM:CurrRow)
WONo = Get_Property(@WINDOW:'.WO_NO','DEFPROP')
WOStep = Get_Property(@WINDOW:'.PROC_STEP_NO','DEFPROP')
IF WONo = '' OR WOStep = '' THEN RETURN
WOStepKey = WONo:'*':WOStep
IF RDSNo NE '' THEN
Set_Property(@WINDOW,'@RETURN_FROM_RDS',WOStepKey) ;* Bullshit lashup to work with multiple RDS windows
thisFormName = 'RDS'
thisFormWindowUp = Get_Property(thisFormName,'VISIBLE') ;* Returns 0 = hidden, 1 = visible, 2 = minimized, 3 = maximized
IF thisFormWindowUp = '' THEN
Start_Window(thisFormName, AppMain, RDSNo:'*CENTER', '', '') ;* Put up the card window
RETURN
END
IF thisFormWindowUp = 2 THEN Set_Property(thisFormName,'VISIBLE',9) ;* Restore the window if minimized
IF Get_Property(thisFormName,'SAVEWARN') THEN
Send_Event(thisFormName,'CLEAR') ;* Clear anything existing (prompts for save first)
END
END
RETURN
* * * * * * *
BrowseRDS:
* * * * * * *
WONo = Get_Property(@WINDOW:'.WO_NO','TEXT')
StepNo = Get_Property(@WINDOW:'.PROC_STEP_NO','TEXT')
IF WONo NE '' AND StepNo NE '' THEN
WOStepKey = WONo:'*':StepNo
END ELSE
RETURN
END
CtrlEntID = @WINDOW:'.RUNS'
CurrPos = Get_Property(CtrlEntID,'SELPOS')
CurrCol = CurrPos<1>
CurrRow = CurrPos<2>
RDSNos = Get_Property(CtrlEntID,'ARRAY')<2> ;* Multivalue list of RDS Nos
LOOP
TestChar = RDSNos[-1,1]
UNTIL TestChar NE @VM OR RDSNos = ''
RDSNos[-1,1] = ''
REPEAT
IF RDSNos = '' THEN RETURN
WONo = Get_Property(@Window:'.WO_NO', 'TEXT')
RDSKeys = Dialog_Box('NDW_RDS_QUERY', @Window, WONo)
IF RDSKeys = '' THEN RETURN
Set_Property(@WINDOW,'@RETURN_FROM_RDS',WOStepKey) ;* Bullshit lashup to work with multiple RDS windows
thisFormName = 'RDS'
thisFormWindowUp = Get_Property(thisFormName,'VISIBLE') ;* Returns 0 = hidden, 1 = visible, 2 = minimized, 3 = maximized
IF thisFormWindowUp = '' THEN
Start_Window(thisFormName,AppMain,RDSKeys:'*CENTER', '', '') ;* Put up the card window
RETURN
END
IF thisFormWindowUp = 2 THEN Set_Property(thisFormName,'VISIBLE',9) ;* Restore the window if minimized
IF Get_Property(thisFormName,'SAVEWARN') THEN
Send_Event(thisFormName,'CLEAR') ;* Clear anything existing (prompts for save first)
END
RETURN
* * * * * * *
WMInDC:
* * * * * * *
CtrlEntID = @WINDOW:'.WM_IN'
CurrPos = Get_Property(CtrlEntID,'SELPOS')
CurrCol = CurrPos<1>
CurrRow = CurrPos<2>
WONo = Get_Property(@WINDOW:'.WO_NO','DEFPROP')
StepNo = Get_Property(@WINDOW:'.PROC_STEP_NO','DEFPROP')
CassNo = Get_Property(CtrlEntID,'CELLPOS',1:@FM:CurrRow)
IF WONo NE '' AND StepNo NE '' AND CassNo NE '' THEN
DetWindow = 'WM_IN'
DetKeys = WONo:'*':StepNo:'*':CassNo
DefaultRec = ''
RetKey = WONo:'*':StepNo
RetPage = 1
RetCtrl = CtrlEntID
RetPos = CurrPos
oAParms = DetWindow:@RM:DetKeys:@RM:DefaultRec:@RM:RetKey:@RM:RetPage:@RM:RetCtrl:@RM:RetPos
obj_AppWindow('ViewNewDetail',oAParms)
IF Get_Status(errCode) THEN
ErrMsg(errCode)
END
END
RETURN
* * * * * * *
WMOutDC:
* * * * * * *
CtrlEntID = @WINDOW:'.WM_OUT'
CurrPos = Get_Property(CtrlEntID,'SELPOS')
CurrCol = CurrPos<1>
CurrRow = CurrPos<2>
WONo = Get_Property(@WINDOW:'.WO_NO','DEFPROP')
StepNo = Get_Property(@WINDOW:'.PROC_STEP_NO','DEFPROP')
CassNo = Get_Property(CtrlEntID,'CELLPOS',1:@FM:CurrRow)
IF WONo NE '' AND StepNo NE '' AND CassNo NE '' THEN
DetWindow = 'WM_OUT'
DetKeys = WONo:'*':StepNo:'*':CassNo
DefaultRec = ''
RetKey = WONo:'*':StepNo
RetPage = 1
RetCtrl = CtrlEntID
RetPos = CurrPos
oAParms = DetWindow:@RM:DetKeys:@RM:DefaultRec:@RM:RetKey:@RM:RetPage:@RM:RetCtrl:@RM:RetPos
obj_AppWindow('ViewNewDetail',oAParms)
IF Get_Status(errCode) THEN
ErrMsg(errCode)
END
END
RETURN
* * * * * * *
CreateRDS:
* * * * * * *
CtrlEntID = @WINDOW:'.RUNS'
WONo = Get_Property(@WINDOW:'.WO_NO','DEFPROP')
WOStep = Get_Property(@WINDOW:'.PROC_STEP_NO','DEFPROP')
IF WONo = '' OR WOStep = '' THEN RETURN
WMInRem = Get_Property(@WINDOW:'.WM_IN','ARRAY')<COL$WM_IN_REMAINING> ;* Just need remaining wafers column
FOR NextCassNo = 1 TO COUNT(WMInRem,@VM) + (WMInRem NE '')
UNTIL WMInRem<1,NextCassNo> > 0
NEXT NextCassNo
// 3/20/2019 - DJS - Deprecated to avoid locking WO_LOG table unnecessarily.
* RunNo = obj_WO_Log('NextWORun',WONo:@RM:WOStep) ;* New RDS Run order number
* IF Get_Status(errCode) THEN
* ErrMsg(errCode)
* RETURN
* END
RunNo = Work_Order_Services('GetNextRunNo', WONo, WOStep)
If Error_Services('HasError') then
ErrorMsg = Error_Services('GetMessage')
ErrMsg('An error occurred creating an RDS. Please contact FI Support. ':ErrorMsg)
Return
end
IF RunNo = '' THEN RETURN
WOMatRec = XLATE('WO_MAT',WONo:'*':NextCassNo,'','X')
CassLotNo = WOMatRec<WO_MAT_LOT_NO$>
CassWaferQty = '0'
CassPartNo = WOMatRec<WO_MAT_CUST_PART_NO$>
CassSubPartNo = WOMatRec<WO_MAT_SUB_PART_NO$>
CassSubInvID = '' ;* This isn't being used
CassOrderItem = WOMatRec<WO_MAT_ORDER_ITEM$>
CassSubVendCode = WOMatRec<WO_MAT_SUB_VEND_CD$>
WORec = XLATE('WO_LOG',WONo,'','X')
OrderNo = WORec<WO_LOG_ORDER_NO$>
CustNo = WORec<WO_LOG_CUST_NO$>
PromiseDt = WORec<WO_LOG_PROMISE_SHIP_DT$>
PONo = XLATE('ORDER',OrderNo,ORDER_PO_NO$,'X')
QuoteNo = XLATE('ORDER_DET',OrderNo:'*':CassOrderItem,ORDER_DET_QUOTE_NO$,'X')
WOStepCnt = COUNT(WORec<WO_LOG_WO_STEP_KEY$>,@VM) + (WORec<WO_LOG_WO_STEP_KEY$> NE '')
WOStepKey = WONo:'*':WOStep
IF WOStepKey = WORec<WO_LOG_WO_STEP_KEY$>[-1,'B':@VM] THEN
LastStep = 1
END ELSE
LastStep = 0
END
PSN = XLATE('WO_STEP',WOStepKey,WO_STEP_PROD_SPEC_ID$,'X')
*SubstrateSpec = XLATE('PROD_SPEC',PSN,PROD_SPEC_SPEC_SUBSTRATE$,'X')
ReactorType = XLATE('PROD_SPEC',PSN,PROD_SPEC_REACTOR_TYPE$,'X') ;* Not used in program JCH 8/28/2014
EpiPN = XLATE('WO_LOG',WONo,WO_LOG_EPI_PART_NO$,'X')
SubSupplyBy = XLATE('EPI_PART',EpiPN,EPI_PART_SUB_SUPP_BY$,'X') ;*SubstrateSpec<1,QSSubWafersSupBy$>
SubPreClean = XLATE('PRS_STAGE',PSN:'*PRE',PRS_STAGE_CLEAN_TOOL$,'X') ;*SubstrateSpec<1,QSSubPreClean$>
SubPostClean = XLATE('PRS_STAGE',PSN:'*POST',PRS_STAGE_CLEAN_TOOL$,'X') ;*SubstrateSpec<1,QSSubPostClean$>
OrgColor = Set_Property(@WINDOW:'.STATUS_LINE','BACKCOLOR',YELLOW$)
Parms = WONo:@RM
Parms := WOStep:@RM
Parms := LastStep:@RM
Parms := RunNo:@RM ; * Was CassNo -> Verify what happens in obj_RDS('Create'...) with this number
Parms := QuoteNo:@RM
Parms := OrderNo:@RM
Parms := CassOrderItem:@RM
Parms := CustNo:@RM
Parms := PONo:@RM
Parms := PSN:@RM
Parms := SubSupplyBy:@RM
Parms := SubPreClean:@RM
Parms := SubPostClean:@RM
Parms := PromiseDt:@RM
Parms := CassLotNo:@RM
Parms := CassPartNo:@RM
Parms := CassWaferQty:@RM
Parms := CassSubPartNo:@RM
Parms := '':@RM ; // QXJ flag
Parms := CassSubVendCode
RDSNo = obj_RDS('Create',Parms)
IF Get_Status(errCode) THEN
ErrMsg(errCode)
obj_Appwindow('LoadFormKeys',@WINDOW:@RM:WOStepKey)
RETURN
END
Send_Info(STR(' ',100))
Dummy = Set_Property(@WINDOW:'.STATUS_LINE','BACKCOLOR',OrgColor)
IF RDSNo NE '' THEN
Set_Property(@WINDOW,'@RETURN_FROM_RDS',WOStepKey) ;* Bullshit lashup to work with multiple RDS windows
thisFormName = 'RDS'
thisFormWindowUp = Get_Property(thisFormName,'VISIBLE') ;* Returns 0 = hidden, 1 = visible, 2 = minimized, 3 = maximized
IF thisFormWindowUp = '' THEN
Start_Window(thisFormName,AppMain,RDSNo:'*CENTER', '', '') ;* Put up the card window
RETURN
END
IF thisFormWindowUp = 2 THEN Set_Property(thisFormName,'VISIBLE',9) ;* Restore the window if minimized
IF Get_Property(thisFormName,'SAVEWARN') THEN
Send_Event(thisFormName,'CLEAR') ;* Clear anything existing (prompts for save first)
END
END
RETURN
* * * * * * *
ViewPSN:
* * * * * * *
IF Security_Check( 'Prod Spec', Read$ ) THEN
PSNo = Get_Property(@WINDOW:'.PROD_SPEC_ID','DEFPROP')
IF PSNo = '' THEN RETURN
END ELSE
Security_Err_Msg( 'Prod Spec', Read$ )
RETURN
END
Start_Window ( 'PROD_SPEC', @WINDOW, PSNo:'*CENTER', '', '' ) ;* This is an old style window so call with the old style code
RETURN
* * * * * * *
RemWMOut:
* * * * * * *
WONo = Get_Property(@WINDOW:'.WO_NO','TEXT')
IF WONo = '' THEN RETURN
*Send_Event(@WINDOW,'WRITE')
WORec = XLATE('WO_LOG',WONo,'','X')
WOMatKeys = WORec<WO_LOG_WO_MAT_KEY$>
WMOutKeys = XLATE('WO_MAT',WOMatKeys,WO_MAT_WMO_KEY$,'X')
WMOutCnt = COUNT(WMOutKeys,@VM) + (WMOutKeys NE '')
Display = ''
DispLine = 1
IF WMOutCnt > 0 THEN
FOR I = WMOutCnt TO 1 STEP -1
WMORec = XLATE('WM_OUT',WMOutKeys<1,I>,'','X')
WMO_RdsNos = WMORec<WM_OUT_RDS$>
WMO_NCRNos = WMORec<WM_OUT_SLOT_NCR$>
WMO_UMWCassIDs = WMORec<WM_OUT_UMW_CASS_ID$>
CONVERT @VM TO '' IN WMO_RdsNos
CONVERT @VM TO '' IN WMO_NCRNos
CONVERT @VM TO '' IN WMO_UMWCassIDs
UNTIL WMO_RdsNos NE '' OR WMO_NCRNos NE '' OR WMO_UMWCassIDs NE ''
Display<1,DispLine,1> = FIELD(WOMatKeys<1,I>,'*',2)
Display<1,DispLine,2> = OCONV(obj_WM_Out('CurrStatus',WOMatKeys<1,I>:@RM:WMORec),'[WO_MAT_CURR_STATUS_CONV]')
Display<1,DispLine,3> = WMOutKeys<1,I>
DispLine += 1
NEXT I
IF Display NE '' THEN
TypeOver = ''
TypeOver<PDISPLAY$> = Display
TypeOver<PTITLE$> = 'Unused WM_OUT Cassettes'
WMOData = Popup(@WINDOW,TypeOver,'UNUSED_WM_OUT')
IF WMOData = '' OR WMOData = CHAR(27) THEN RETURN ;* Cancelled out
END ELSE
ErrMsg('All cassettes on this Work Order have started processing.')
obj_AppWindow('LoadFormKeys',@WINDOW:@RM:WONo)
RETURN
END
DelWMOutKeys = ''
FOR I = 1 TO COUNT(WMOData,@FM) + (WMOData NE '')
DelWMOutKeys<1,I> = WMOData<I,3>
NEXT I
TestWMOutKeys = DelWMOutKeys
CONVERT @VM TO '' IN TestWMOutKeys
IF TestWMOutKeys NE '' THEN
Set_Status(0)
obj_WM_Out('Delete',DelWMOutKeys)
IF Get_Status(errCode) THEN
ErrMsg(errCode)
END
END
IF Get_Status(errCode) THEN
ErrMsg(errCode)
END
END
IF Display = '' THEN
ErrMsg('All cassettes on this Work Order have had wafers placed in them.')
RETURN
END
IF Get_Status(errCode) THEN
ErrMsg(errCode)
END
*obj_AppWindow('LoadFormKeys',@WINDOW:@RM:WONo)
Send_Event(@WINDOW,'READ')
RETURN
* * * * * * *
WaferTrace:
* * * * * * *
WONo = Get_Property(@WINDOW:'.WO_NO','TEXT')
IF WONo = '' THEN RETURN
CALL Reconcile_EPI_Wo(WONo)
RETURN
* * * * * * *
ControlPlanClick:
* * * * * * *
WONo = Get_Property(@WINDOW:'.WO_NO','DEFPROP')
PSNo = Get_Property(@WINDOW:'.PROD_SPEC_ID','DEFPROP')
IF PSNo NE '' AND WONo NE '' THEN
Print_Control_Plan(PSNo,WONo)
END
RETURN