Compile function NDW_PM_OVERRIDE_EVENTS(CtrlEntId, Event, @PARAMS)
/***********************************************************************************************************************
This program is proprietary and is not to be used by or disclosed to others, nor is it to be copied without written
permission from Infineon.
Name : NDW_PM_Override_Events
Description : This function acts as a commuter module for all events related to this window.
Notes : Commuter Modules are automatically called from the Promoted_Events function which is called by the
application-specific promoted event handler. This makes it possible to add QuickEvents that need to
execute Basic+ logic without having use the Form Designer to make the association, although this is
limited to the events which are currently promoted.
If the form needs to call the commuter module directly then the QuickEvent parameters should be
formatted like this:
'@SELF','@EVENT',['@PARAM1','@PARAMx']
Parameters :
CtrlEntId [in] -- The fully qualified name of the control calling the promoted event
Event [in] -- The event being executed. See the Notes section regarding "PRE" events
Param1-15 [in] -- Additional event parameter holders
EventFlow [out] -- Set to 1 or 0 so the calling event knows whether or not to chain forward. See comments in
EVENT_SETUP insert
History : (Date, Initials, Notes)
06/25/24 djs Created initial commuter module.
***********************************************************************************************************************/
#pragma precomp SRP_PreCompiler
#window NDW_PM_OVERRIDE
$Insert APP_INSERTS
$Insert EVENT_SETUP
$Insert REACTOR_LOG_EQUATES
$insert MESSAGE_BOX_EQUATES
Declare subroutine Placedialog, Message_Box
// Update the arguments so that the OpenInsight OLE event will treate the ActiveX event as a native event handler.
If Event EQ 'OLE' then
Transfer Event to OIEvent
Transfer Param1 to Event
Transfer Param2 to Param1
Transfer Param3 to Param2
Transfer Param4 to Param3
Transfer Param5 to Param4
Transfer Param6 to Param5
Transfer Param7 to Param6
Transfer Param8 to Param7
end
GoToEvent Event for CtrlEntId else
// Event not implemented
end
Return EventFlow or 1
//-----------------------------------------------------------------------------
// EVENT HANDLERS
//-----------------------------------------------------------------------------
Event WINDOW.CREATE(CreateParam)
RlNo = CreateParam
PmOrderTypes = Xlate('REACTOR_LOG', RLNo, REACTOR_LOG_CHECKLIST_TYPE$, 'X')
for each PmOrderType in PmOrderTypes using @VM setting dummy
Begin Case
Case PmOrderType _EQC 'ASM_HTR_TUBE_CHANGE'
Set_Property(@Window:'.CHB_ASM_HTR_TUBE_CHANGE', 'ENABLED', True$)
Case PmOrderType _EQC 'SEMIANNUAL_PM'
Set_Property(@Window:'.CHB_SEMIANNUAL_PM', 'ENABLED', True$)
Case PmOrderType _EQC 'ANNUAL_PM'
Set_Property(@Window:'.CHB_ANNUAL_PM', 'ENABLED', True$)
Case Otherwise$
Null
End Case
Next PmOrderType
Placedialog(-2, -2)
End Event
Event PUB_SUBMIT.CLICK()
OverrideData = ''
SelectedTypes = ''
If Get_Property(@Window:'.CHB_ASM_HTR_TUBE_CHANGE', 'CHECK') then SelectedTypes<0, -1> = "ASM_HTR_TUBE_CHANGE"
If Get_Property(@Window:'.CHB_SEMIANNUAL_PM', 'CHECK') then SelectedTypes<0, -1> = 'SEMIANNUAL_PM'
If Get_Property(@Window:'.CHB_ANNUAL_PM', 'CHECK') then SelectedTypes<0, -1> = 'ANNUAL_PM'
If SelectedTypes EQ '' then
Message_Box(@Window, "You must select at least one PM type!", "Error", MSG_ICON_EXCLAM$)
return
end else
OverrideData<1, 1> = SelectedTypes
end
OverrideData<2, 1> = Get_Property(@Window:'.EDB_COMMENT', 'TEXT')
If OverrideData<2, 1> EQ '' or Len(OverrideData<2, 1>) LT 4 then
Message_Box(@Window, "Your comment must be at least 4 characters!", "Error", MSG_ICON_EXCLAM$)
return
end
End_Dialog(@Window, OverrideData)
end event
Event PUB_CANCEL.CLICK()
End_Dialog(@Window, '')
end event