Function RDS_PRE_EPI_Events(CtrlEntId, Event, @PARAMS)
/***********************************************************************************************************************
This program is proprietary and is not to be used by or disclosed to others, nor is it to be copied without written
permission from Infineon.
Name : RDS_Pre_Epi_Events
Description : This function acts as a commuter module for all events related to this window.
Notes : Commuter Modules are automatically called from the Promoted_Events function which is called by the
application-specific promoted event handler. This makes it possible to add QuickEvents that need to
execute Basic+ logic without having use the Form Designer to make the association, although this is
limited to the events which are currently promoted.
If the form needs to call the commuter module directly then the QuickEvent parameters should be
formatted like this:
'@SELF','@EVENT',['@PARAM1','@PARAMx']
Parameters :
CtrlEntId [in] -- The fully qualified name of the control calling the promoted event
Event [in] -- The event being executed. See the Notes section regarding "PRE" events
Param1-15 [in] -- Additional event parameter holders
EventFlow [out] -- Set to 1 or 0 so the calling event knows whether or not to chain forward. See comments in
EVENT_SETUP insert
History : (Date, Initials, Notes)
08/13/19 djs Created initial commuter module and began moving script evebts into commuter module.
06/13/24 djm Add new stage-specific supplement system.
***********************************************************************************************************************/
#pragma precomp SRP_PreCompiler
#Window RDS_PRE_EPI
$insert APP_INSERTS
$insert EVENT_SETUP
$insert MSG_EQUATES
$insert RDS_EQUATES
$insert LSL_USERS_EQUATES
$insert PROD_SPEC_EQUATES
$insert WO_MAT_EQUATES
$insert SURFACE_SCAN_EQUATES
$insert REACTOR_EQUATES
$insert PRS_STAGE_EQUATES
$insert COMPANY_EQUATES
$insert WO_MAT_QA_EQUATES
$insert REACT_STATUS_EQUATES
$insert SUPPL_INFO_ARRAY_EQU
$insert CLEAN_INSP_EQUATES
Equ COL$LOG_FILE to 1
Equ COL$LOG_DTM to 2
Equ COL$ACTION to 3
Equ COL$WH_CD to 4
Equ COL$LOC_CD to 5
Equ COL$WO_NOS to 6
Equ COL$CASS_NOS to 7
Equ COL$USER_ID to 8
Equ COL$TAGS to 9
Equ COL$TOOL_ID to 10
Declare subroutine ErrMsg, Set_Status, obj_WO_Mat, obj_WO_Mat_Log, obj_RDS, Set_Property, Send_Event, Database_Services
Declare subroutine Qa_Services, RDS_Services, Dialog_Box
Declare function Dialog_Box, Msg, MemberOf, obj_WO_Mat, Database_Services, Get_Property, obj_React_Status, Get_Status
Declare function QA_Services, Database_Services, Supplement_Services, RDS_Services
SubclassInfo = Form_Services('FindSubclassControl')
Subclass = SubclassInfo<1>
// Update the arguments so that the OpenInsight OLE event will treate the ActiveX event as a native event handler.
If Event EQ 'OLE' then
Transfer Event to OIEvent
Transfer Param1 to Event
Transfer Param2 to Param1
Transfer Param3 to Param2
* Transfer Param4 to Param3
* Transfer Param5 to Param4
* Transfer Param6 to Param5
* Transfer Param7 to Param6
* Transfer Param8 to Param7
end
GoToEvent Event for CtrlEntID
Return EventFlow else EVENT_CONTINUE$
////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
// Events
////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
Event WINDOW.CREATE(CreateParam)
GoSub SetupControls
end event
Event WINDOW.READ()
GoSub SetupControls
end event
Event WINDOW.CLOSE(CancelFlag)
end event
Event WINDOW.CLEAR(bSaveKey, bSuppressWarning, bMaintainFocus, CtrlIDFocus)
end event
Event SUPPL_BUTTON.CLICK()
RDSNo = Get_Property(@Window:'.RDS_NO', 'TEXT')
Dialog_Box('NDW_RDS_SUPP_SIG', @Window, RDSNo :@FM: 'VER' :@FM: FALSE$)
end event
Event PUB_SIGN.CLICK()
ButtonText = Get_Property(@Window:'.PUB_SIGN', 'TEXT')
Begin Case
Case ButtonText EQ 'Sign'
GoSub SignPreEpi
Case ButtonText EQ 'Unsign'
GoSub UnsignPreEpi
End Case
If Error_Services('HasError') then
ErrorMsg = Error_Services('GetMessage')
ErrMsg(ErrorMsg)
end
Set_Property(@Window, 'SAVEWARN', False$)
Set_Status(0)
Send_Event(@Window, 'READ')
end event
////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
// Internal GoSubs
////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
SetupControls:
RDSNo = Get_Property(@Window:'.RDS_NO', 'TEXT')
GoSub ReactorEdlCtrlSetup
GoSub PubSignCtrlSetup
return
ReactorEdlCtrlSetup:
// Disable reactor edit line control if the RDS has been assigned.
If RDSNo NE '' then
PreEpiSig = Database_Services('ReadDataColumn', 'RDS', RDSNo, RDS_PRE_EPI_SIG$, True$, 0, False$)
If Error_Services('NoError') then
If PreEpiSig NE '' then
Set_Property(@Window:'.REACTOR', 'ENABLED', False$)
Set_Property(@Window:'.REACTOR', 'BACKCOLOR', READONLY_GREEN$)
end else
Set_Property(@Window:'.REACTOR', 'ENABLED', True$)
Set_Property(@Window:'.REACTOR', 'BACKCOLOR', EDIT_ACTIVE_WHITE$)
end
end else
Set_Property(@Window:'.REACTOR', 'ENABLED', False$)
Set_Property(@Window:'.REACTOR', 'BACKCOLOR', READONLY_GREEN$)
end
end
return
PubSignCtrlSetup:
If RDSNo NE '' then
PreEpiSig = Database_Services('ReadDataColumn', 'RDS', RDSNo, RDS_PRE_EPI_SIG$, True$, 0, False$)
If Error_Services('NoError') then
If PreEpiSig NE '' then
Set_Property(@Window:'.PUB_SIGN', 'TEXT', 'Unsign')
end else
Set_Property(@Window:'.PUB_SIGN', 'TEXT', 'Sign')
end
end
end
return
SignPreEpi:
RDSNo = Get_Property(@Window:'.RDS_NO' ,'DEFPROP')
WfrQty = Get_Property(@Window:'.VERIFY_QTY','TEXT')
Reactor = Get_Property(@Window:'.REACTOR' ,'TEXT')
PREInstAckReq = Xlate('RDS', RDSNo, 'PRE_INST_ACK_REQ', 'X')
PreAuthenticated = FALSE$
If PreInstAckReq EQ True$ then
RDS_Services('RDSVerifyInst', RDSNo, 'PRE')
end
SupplAckReq = Supplement_Services('UnacknowledgedSupplementCheck', 'RDS', RDSNo, 'VER')
IF (SupplAckReq NE FALSE$) then
Response = Dialog_Box('NDW_RDS_SUPP_SIG', @Window, RDSNo :@FM: 'VER' :@FM: FALSE$)
If Response EQ False$ then
return
end else
PreAuthenticated = TRUE$
end
end
ReadyToSign = QA_Services('PreEpiSignatureReady', RDSNo, @User4, WfrQty, Reactor)
If (ReadyToSign EQ True$) then
If PreAuthenticated EQ FALSE$ then
Response = Dialog_Box('NDW_VERIFY_USER', @WINDOW)
Valid = Response<1>
If (Valid EQ True$) then
QA_Services('SignPreEpiStage', RDSNo, @USER4, WfrQty, Reactor)
end
end else
QA_Services('SignPreEpiStage', RDSNo, @USER4, WfrQty, Reactor)
end
end
return
UnsignPreEpi:
RDSNo = Get_Property(@Window:'.RDS_NO','DEFPROP')
VerCheckParams = ''
VerCheckParams<4> = 'Permission needed for Pre-Epi Unsign on RDS# ' : RDSNo
UserVerCheck = Dialog_Box('NDW_VERIFY_USER', @Window, '':@FM:'':@FM:'':@FM:VerCheckParams)
ValidUserCheck = UserVerCheck<1>
If ValidUserCheck then
ValidUserId = UserVerCheck<2>
If ValidUserId NE '' then
RDS_Services('UnsignPreEpiSignature', RDSNo, ValidUserId)
end
end
return