Compile function NDW_SCHED_EVENTS_EVENTS(CtrlEntId, Event, @PARAMS)
/***********************************************************************************************************************
This program is proprietary and is not to be used by or disclosed to others, nor is it to be copied without written
permission from Infineon.
Name : NDW_Sched_Events_Events
Description : This function acts as a commuter module for all events related to this window.
Notes : Commuter Modules are automatically called from the Promoted_Events function which is called by the
application-specific promoted event handler. This makes it possible to add QuickEvents that need to
execute Basic+ logic without having use the Form Designer to make the association, although this is
limited to the events which are currently promoted.
If the form needs to call the commuter module directly then the QuickEvent parameters should be
formatted like this:
'@SELF','@EVENT',['@PARAM1','@PARAMx']
Parameters :
CtrlEntId [in] -- The fully qualified name of the control calling the promoted event
Event [in] -- The event being executed. See the Notes section regarding "PRE" events
Param1-15 [in] -- Additional event parameter holders
EventFlow [out] -- Set to 1 or 0 so the calling event knows whether or not to chain forward. See comments in
EVENT_SETUP insert
History : (Date, Initials, Notes)
01/19/23 djs Converted from MASTER_PM_LIST.
***********************************************************************************************************************/
#pragma precomp SRP_PreCompiler
#window NDW_SCHED_EVENTS
$Insert EVENT_SETUP
$Insert MSG_EQUATES
$Insert APPCOLORS
$Insert LSL_USERS_EQU
$Insert SECURITY_RIGHTS_EQU
$Insert PM_SPEC_EQUATES
$Insert POPUP_EQUATES
$INSERT LOGICAL
$Insert TOOL_EQUATES
$Insert RTI_STYLE_EQUATES
$Insert RLIST_EQUATES
$Insert OIPRINT_EQUATES
EQU COL$PMS_ID TO 1
EQU COL$DESC TO 2
EQU COL$TOOL_ID TO 3
EQU COL$TOOL_DESC TO 4
EQU COL$TOOL_STATUS TO 5
EQU COL$TOOL_CYCLE_CNT TO 6
EQU COL$LAST_PM TO 7
EQU COL$EARLY_START TO 8
EQU COL$SCHED_START TO 9
EQU COL$LATE_START TO 10
EQU COL$PM_STATUS TO 11
Declare subroutine obj_Appwindow, Set_Property, Yield, Send_Message, End_Dialog, Send_Event, ErrMsg, Set_Status
Declare subroutine Start_Window
Declare function MemberOf, Tool_Services, Send_Message, obj_PM_Spec, SRP_Array
// Update the arguments so that the OpenInsight OLE event will treate the ActiveX event as a native event handler.
If Event EQ 'OLE' then
Transfer Event to OIEvent
Transfer Param1 to Event
Transfer Param2 to Param1
Transfer Param3 to Param2
Transfer Param4 to Param3
Transfer Param5 to Param4
Transfer Param6 to Param5
Transfer Param7 to Param6
Transfer Param8 to Param7
end
GoToEvent Event for CtrlEntId else
// Event not implemented
end
Return EventFlow or 1
////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
// Event Handlers
////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
Event WINDOW.CREATE(CreateParam)
obj_Appwindow('Create',@WINDOW)
IF MemberOf (@USER4, 'PM_SCHED') ELSE
Message = 'You do not have the proper security to enter the Master PM Schedule List...'
Message<MICON$> = 'H'
Void = Msg( '', Message )
Send_Event(@Window, 'CLOSE')
END
PMStyles = Send_Message(@WINDOW:'.SCHED','COLSTYLE',0,'')
PMStyles<COL$PMS_ID> = BitOr(PMStyles<COL$PMS_ID>,DTCS_OPTIONSBUTTON$)
void = Send_Message(@WINDOW:'.SCHED','COLSTYLE',0,PMStyles)
ToolList = Tool_Services('GetTools')
ToolList = SRP_Array('SortSimpleList', ToolList, 'AscendingText', @FM)
Set_Property(@WINDOW :'.COMBO_FILTER', 'LIST', ToolList)
Send_Message(@WINDOW:'.OLE_BTN_CLEAR_FILTER', 'QUALIFY_EVENT', 'OLE.OnClick', 1)
GOSUB Refresh
PrevCursor = Set_Property("SYSTEM", "CURSOR", "A")
Yield()
End Event
Event REFRESH.CLICK()
GoSub Refresh
end event
Event WINDOW.GOTFOCUS(PrevFocusID)
GoSub Refresh
end event
Event WINDOW.CLOSE(CancelFlag)
End_Dialog(@WINDOW,'')
end event
Event SCHED.DBLCLK(CtrlKey, ShiftKey, MouseButton)
RowData = Get_Property(CtrlEntId,'ROWDATA')
PMSId = RowData<COL$PMS_ID>
obj_AppWindow('ViewRelated','PM_SPEC':@RM:PMSId)
end event
Event SCHED.OPTIONS()
RowData = Get_Property(CtrlEntId,'ROWDATA')
PMSId = RowData<COL$PMS_ID>
TypeOver = ''
TypeOver<PDISPLAY$> = 'WITH PMS_ID = ':QUOTE(PMSId):' BY-DSND ENTER_DTM'
TypeOver<PSELECT$> = '2'
TypeOver<PTYPE$> = 'K'
PMKeys = Popup(@WINDOW,TypeOver,'PM_HISTORY')
IF PMKeys = '' OR PMKeys = CHAR(27) THEN RETURN
obj_Appwindow('ViewRelated','PM':@RM:PMKeys:@RM:@RM)
end event
Event OLE_BTN_CLEAR_FILTER.OnClick(Point, Button, Shift, Ctrl)
Set_Property(@WINDOW:'.COMBO_FILTER', 'TEXT', '')
GoSub Refresh
end event
Event COMBO_FILTER.CHANGED(NewData)
GoSub Refresh
end event
Event PUB_NEW_PM_SPEC.CLICK()
Start_Window('PM_SPEC', @Window, '')
end event
////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
// Internal GoSubs
////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
Refresh:
Def = ""
Def<MTEXT$> = "Loading scheduled preventive events..."
Def<MTYPE$> = "U"
MsgUp = Msg(@window, Def) ;* display the processing message
ToolFilter = Get_Property(@WINDOW :'.COMBO_FILTER', 'TEXT')
// PM_SPEC and PM tables refactored for use with Silicon.
// GaN related PM_SPEC and PM records exist for PMS_SPEC keys below 662.
ShowArchived = Get_Property(@Window:'.CHK_SHOW_ARCHIVED', 'CHECK')
ShowOOS = Get_Property(@Window:'.CHK_SHOW_OOS', 'CHECK')
ShowScrubbers = Get_Property(@Window:'.CHK_SHOW_SCRUBBERS', 'CHECK')
Query = 'SELECT PM_SPEC WITH FIVE_S_FLAG NE 1 '
If Not(ShowArchived) then Query := 'AND WITH ARCHIVED NE 1 '
If Not(ShowScrubbers) then Query := 'AND WITH PM_CLASS NE ' : Quote('SCRUBBER')
ErrCode = ''
Set_Status(0)
RList(Query, TARGET_ACTIVELIST$, '', '', '')
If Not(Get_Status(ErrCode)) then
Open 'PM_SPEC' to TableIn then
Done = False$
SchedList = ''
SchedColors = ''
EQ_LOC = ''
Today = Date()
SortedStarts = ''
Loop
ReadNext PMSId else Done = True$
Until Done
READ PMSpecRec FROM TableIn,PMSId THEN
ActPMKeys = PMSpecRec<PM_SPEC_PM_KEYS$>
Units = PMSpecRec<PM_SPEC_UNITS$>
ToolID = PMSpecRec<PM_SPEC_TOOL_ID$>
ToolStatus = XLATE('TOOL',ToolID,'CURR_MODE_DESC','X')
If ( ( (ToolID _EQC ToolFilter) or (ToolFilter EQ '') ) and ( (ToolStatus NE 'Out of Service') or ShowOOS ) ) then
Conv = ''
IF Units = 'D' THEN Conv = 'D'
IF Units = 'T' THEN Conv = 'DT'
IF Units = 'Q' THEN Conv = 'MD0'
Today = Date()
CurrDtm = ICONV(OCONV(Date(),'D'):' ':OCONV(Time(),'MT'), 'DT' )
CurrCnt = XLATE('TOOL',ToolID,TOOL_CYCLE_CNT$,'X') ;* Curr Cycle Count on Tool
Now = ''
IF Units = 'D' THEN Now = Today
IF Units = 'T' THEN Now = CurrDtm
IF Units = 'Q' THEN Now = CurrCnt
pmCnt = COUNT(ActPMKeys,@VM) + (ActPMKeys NE '')
IF pmCnt = 0 THEN pmCnt = 1
SchedStarts = obj_PM_Spec('SchedStart',PMSId:@RM:PMSpecRec)
EarlyStarts = obj_PM_Spec('EarlyStart',PMSId:@RM:PMSpecRec)
LateStarts = obj_PM_Spec('LateStart',PMSId:@RM:PMSpecRec)
FOR I = 1 TO pmCnt
SchedStart = SchedStarts<1,I>
EarlyStart = EarlyStarts<1,I>
LateStart = LateStarts<1,I>
IF Conv NE '' THEN
SchedStartIn = ICONV(SchedStart,Conv)
EarlyStartIn = ICONV(EarlyStart,Conv)
LateStartIn = ICONV(LateStart,Conv)
END ELSE
SchedStartIn = SchedStart
EarlyStartIn = EarlyStart
LateStartIn = LateStart
END
BEGIN CASE
CASE SchedStartIn = '' ; LineColor = WHITE$
CASE EarlyStartIn = '' AND Now LE SchedStartIn ; LineColor = GREEN$
CASE Now < EarlyStartIn ; LineColor = GREEN$
CASE Now < SchedStartIn ; LineColor = YELLOW$
CASE LateStartIn = '' AND Now = SchedStartIn ; LineColor = ORANGE$
CASE LateStartIn = '' AND Now > SchedStartIn ; LineColor = RED$
CASE Now > LateStartIn ; LineColor = RED$
CASE Now GE SchedStartIn ; LineColor = ORANGE$ ;
END CASE
LastPM = OConv(Xlate('PM_SPEC', PMSId, 'LAST_PM_COMP_DTM', 'X'), 'DT4/^H')
PMDesc = PMSpecRec<PM_SPEC_DESC$>
ToolID = PMSpecRec<PM_SPEC_TOOL_ID$>
ToolDesc = XLATE('TOOL',ToolID,TOOL_TOOL_DESC$,'X')
ToolLocation = XLATE('TOOL',ToolID,'LOCATION','X')
LastPM = LastPM
IF SchedStartIn = '' THEN
Pos = -1
END ELSE
LOCATE SchedStartIn IN SortedStarts BY 'AR' USING @FM SETTING Pos THEN
NULL
END ELSE
NULL
END
SortedStarts = INSERT(SortedStarts,Pos,0,0,SchedStartIn)
END
SchedLine = PMSId
SchedLine<1,COL$DESC> = PMDesc
SchedLine<1,COL$TOOL_ID> = ToolID
SchedLine<1,COL$TOOL_DESC> = ToolDesc
SchedLine<1,COL$TOOL_STATUS> = ToolStatus
SchedLine<1,COL$TOOL_CYCLE_CNT> = CurrCnt
SchedLine<1,COL$LAST_PM> = LastPM
SchedLine<1,COL$EARLY_START> = EarlyStart
SchedLine<1,COL$SCHED_START> = SchedStart
SchedLine<1,COL$LATE_START> = LateStart
SchedLine<1,COL$PM_STATUS> = XLATE('PM',ActPMKeys<1,I>,'STATUS','X') ;*PMStatus
SchedList = INSERT(SchedList,Pos,0,0,SchedLine)
SchedColors = INSERT(SchedColors,Pos,0,0,LineColor)
NEXT I
end
END ;* End of PM Rec read
Repeat
SchedList<-1> = STR(@VM,10)
Set_Property(@WINDOW:'.Sched','LIST',SchedList)
SchedCnt = COUNT(SchedList,@FM) + (SchedList NE '')
FOR I = 1 TO SchedCnt
stat = Send_Message(@WINDOW:'.SCHED','COLOR_BY_POS',0,I,SchedColors<I>)
NEXT I
end else
ErrorMsg = 'Unable to open "PM_SPEC" table.'
ErrMsg(ErrorMsg)
end
end else
ErrorMsg = 'Error calling RList. Error code: ':ErrCode
ErrMsg(ErrorMsg)
end
Msg(@window, MsgUp) ;* take down the processing message
return