Function NDW_Scheduler_Cancel_WO_Events(CtrlEntId, Event, Param1, Param2, Param3, Param4, Param5, Param6, Param7, Param8, Param9, Param10, Param11, Param12, Param13, Param14, Param15)
|
|
/***********************************************************************************************************************
|
|
|
|
This program is proprietary and is not to be used by or disclosed to others, nor is it to be copied without written
|
|
permission from Infineon.
|
|
|
|
Name : NDW_Scheduler_Cancel_WO_Events
|
|
|
|
Description : This function acts as a commuter module for all events related to this window.
|
|
|
|
Notes : Commuter Modules are automatically called from the Promoted_Events function which is called by the
|
|
application-specific promoted event handler. This makes it possible to add QuickEvents that need to
|
|
execute Basic+ logic without having use the Form Designer to make the association, although this is
|
|
limited to the events which are currently promoted.
|
|
|
|
If the form needs to call the commuter module directly then the QuickEvent parameters should be
|
|
formatted like this:
|
|
|
|
'@SELF','@EVENT',['@PARAM1','@PARAMx']
|
|
|
|
Parameters :
|
|
CtrlEntId [in] -- The fully qualified name of the control calling the promoted event
|
|
Event [in] -- The event being executed. See the Notes section regarding "PRE" events
|
|
Param1-15 [in] -- Additional event parameter holders
|
|
EventFlow [out] -- Set to 1 or 0 so the calling event knows whether or not to chain forward. See comments in
|
|
EVENT_SETUP insert
|
|
|
|
History : (Date, Initials, Notes)
|
|
01/18/2021 djs Created initial commuter module.
|
|
|
|
***********************************************************************************************************************/
|
|
|
|
#pragma precomp SRP_PreCompiler
|
|
#Window NDW_SCHEDULER_CANCEL_WO
|
|
|
|
$insert APP_INSERTS
|
|
$insert EVENT_SETUP
|
|
$insert MSG_EQUATES
|
|
$insert SCHED_DET_NG_EQUATES
|
|
$insert WO_LOG_EQUATES
|
|
$insert WO_SCHEDULE_NG_EQUATES
|
|
$insert REACTOR_EQUATES
|
|
|
|
Equ OI_DISABLED_GREY$ TO 239 + (239*256) + (239*65536)
|
|
|
|
WorkOrderCtrls = 'OLE_DIV_WORK_ORDER_DETAILS,WO_NO_LABEL,WO_NO,EPI_PART_LABEL,EPI_PART,DESCRIPTION_LABEL,DESCRIPTION,CUSTOMER_NAME_LABEL,CUSTOMER_NAME,'
|
|
WorkOrderCtrls := 'TOTAL_WAFERS_LABEL,TOTAL_WAFERS,TOTAL_REMAINING_LABEL,TOTAL_REMAINING,PERCENT_COMPLETE_LABEL,PERCENT_COMPLETE'
|
|
DateRangeCtrls = 'SCHEDULE_START_DTM_LABEL,SCHEDULE_START_DTM,SCHEDULE_END_DTM_LABEL,SCHEDULE_END_DTM,DAYS_LABEL,DAYS'
|
|
|
|
Declare function SRP_Array, Schedule_Services, Database_Services, Work_Order_Services, SRP_Math
|
|
Declare function Epi_Part_Services
|
|
Declare subroutine obj_Appwindow, Center_Window, Schedule_Services, Form_Services, SRP_Show_Window
|
|
Declare subroutine Form_Services
|
|
|
|
SubclassInfo = Form_Services('FindSubclassControl')
|
|
Subclass = SubclassInfo<1>
|
|
|
|
// Update the arguments so that the OpenInsight OLE event will treate the ActiveX event as a native event handler.
|
|
If Event EQ 'OLE' then
|
|
Transfer Event to OIEvent
|
|
Transfer Param1 to Event
|
|
Transfer Param2 to Param1
|
|
Transfer Param3 to Param2
|
|
Transfer Param4 to Param3
|
|
Transfer Param5 to Param4
|
|
Transfer Param6 to Param5
|
|
Transfer Param7 to Param6
|
|
Transfer Param8 to Param7
|
|
end
|
|
|
|
Type = Get_Property(CtrlEntId, 'TYPE')
|
|
If Type EQ 'RADIOBUTTON' then
|
|
Convert ' ' to '_' in CtrlEntID
|
|
end
|
|
|
|
GoToEvent Event for CtrlEntID
|
|
|
|
Return EventFlow else EVENT_CONTINUE$
|
|
|
|
|
|
////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
|
|
// Events
|
|
////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
|
|
|
|
Event WINDOW.CREATE(CreateParam)
|
|
|
|
SchedDetKeyID = CreateParam<3>
|
|
SchedDetRec = Schedule_Services('GetScheduleDetail', SchedDetKeyID)
|
|
WONo = SchedDetRec<SCHED_DET_NG.WO_NO$>
|
|
ReactorNo = SchedDetRec<SCHED_DET_NG.REACT_NO$>
|
|
StartDTM = SchedDetRec<SCHED_DET_NG.START_DTM$>
|
|
StopDTM = SchedDetRec<SCHED_DET_NG.STOP_DTM$>
|
|
EventWfrs = SchedDetRec<SCHED_DET_NG.EVENT_TOTAL_WFRS$>
|
|
Set_Property(@Window : '.WO_NO', 'TEXT', WONo)
|
|
Set_Property(@Window : '.REACTOR_NO', 'TEXT', ReactorNo)
|
|
Set_Property(@Window : '.SCHEDULE_START_DTM', 'INVALUE', StartDTM)
|
|
Set_Property(@Window : '.SCHEDULE_END_DTM', 'INVALUE', StopDTM)
|
|
Set_Property(@Window : '.SCHEDULE_WAFERS', 'INVALUE', EventWfrs)
|
|
Set_Property(@Window, '@SCHEDULE_KEY_ID', ScheduleKeyID)
|
|
|
|
GoSub PopulateControls
|
|
|
|
SRP_Show_Window(@Window, '', 'C', 'C', 1, '', False$, False$)
|
|
|
|
end event
|
|
|
|
|
|
Event WINDOW.CLOSE(CancelFlag)
|
|
|
|
end event
|
|
|
|
|
|
Event PROCEED_BUTTON.CLICK()
|
|
|
|
End_Dialog(@Window, 'Proceed')
|
|
|
|
end event
|
|
|
|
|
|
Event CANCEL_BUTTON.CLICK()
|
|
|
|
End_Dialog(@Window, 'Cancel')
|
|
|
|
end event
|
|
|
|
|
|
|
|
////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
|
|
// Internal GoSubs
|
|
////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
|
|
|
|
SelectAll:
|
|
|
|
Set_Property(CtrlEntId, 'SELECTION', 1 : @FM : 999)
|
|
|
|
return
|
|
|
|
|
|
UpdateScheduleDetails:
|
|
|
|
ScheduleDetail = Schedule_Services('GetScheduleDetail', ScheduleKeyID)
|
|
Set_Property(@Window, '@ORIG_SCHEDULEDETAIL', ScheduleDetail)
|
|
WorkOrder = Get_Property(@Window : '.WO_NO', 'TEXT')
|
|
If WorkOrder NE '' then
|
|
Set_Property(@Window : '.DESCRIPTION', 'TEXT', ScheduleDetail<SCHED_DET_NG.DESC$>)
|
|
end else
|
|
Set_Property(@Window : '.DESCRIPTION', 'TEXT', '')
|
|
end
|
|
|
|
return
|
|
|
|
UpdateCustomerName:
|
|
|
|
WoNo = Get_Property(@Window : '.WO_NO', 'TEXT')
|
|
If WoNo NE '' then
|
|
WorkOrderDetail = Work_Order_Services('GetWorkOrderLogDetail', WONo)
|
|
CustNo = WorkOrderDetail<WO_LOG_CUST_NO$>
|
|
CompanyRow = Database_Services('ReadDataRow', 'COMPANY', CustNo)
|
|
CustName = CompanyRow<42>
|
|
end else
|
|
CustName = ''
|
|
end
|
|
Set_Property(@Window : '.CUSTOMER_NAME', 'TEXT', CustName)
|
|
|
|
return
|
|
|
|
|
|
UpdateReactorDetails:
|
|
|
|
ReactorNo = Get_Property(@Window : '.REACTOR_NO', 'TEXT')
|
|
If Index(ReactorNo, '/', 1) then
|
|
// EpiPro reactors formatted as such, "40/42". We must truncate the reactor number to the first reactor.
|
|
ReactorNo = Field(ReactorNo, '/', 1, 1)
|
|
Set_Property(@Window : '.REACTOR_NO', 'TEXT', ReactorNo)
|
|
end
|
|
ReactorDetails = Schedule_Services('GetReactorDetails', ReactorNo)
|
|
ReactorType = ReactorDetails<REACTOR_REACT_TYPE$>
|
|
Begin Case
|
|
Case ReactorType _EQC 'EPP' ; ReactorType = 'EpiPro'
|
|
Case ReactorType _EQC 'GAN' ; ReactorType = 'GaN'
|
|
End Case
|
|
Set_Property(@Window : '.REACTOR_TYPE', 'TEXT', ReactorType)
|
|
Set_Property(@Window : '.REACTOR_SIZE', 'TEXT', ReactorDetails<REACTOR_SUSC_POCKET_SIZE$>)
|
|
FutureEvents = Schedule_Services('GetScheduleEvents', Date() + 1, '', ReactorNo, '', False$)
|
|
Set_Property(@Window, '@FUTURE_EVENTS', FutureEvents)
|
|
|
|
return
|
|
|
|
|
|
UpdateWorkOrderDetails:
|
|
|
|
WorkOrder = Get_Property(@Window : '.WO_NO', 'TEXT')
|
|
ReactNo = Get_Property(@Window : '.REACTOR_NO', 'TEXT')
|
|
EventWfrs = Get_Property(@Window : '.SCHEDULE_WFRS', 'TEXT')
|
|
|
|
If WorkOrder NE '' then
|
|
WorkOrderDetail = Work_Order_Services('GetWorkOrderLogDetail', WorkOrder)
|
|
EpiPart = WorkOrderDetail<WO_LOG_EPI_PART_NO$>
|
|
TotalWafers = WorkOrderDetail<WO_LOG_WO_QTY$>
|
|
Remaining = Work_Order_Services('GetRemainingWafers', WorkOrder)
|
|
Remaining = Int(Remaining + .5)
|
|
If TotalWafers GT 0 then
|
|
Complete = (TotalWafers - Remaining) / (TotalWafers * 100)
|
|
end else
|
|
Complete = 0
|
|
end
|
|
ReactorType = Get_Property(@Window : '.REACTOR_TYPE', 'TEXT')
|
|
MinutesPerWafer = Epi_Part_Services('GetMinutesPerWaferScheduler', EpiPart, ReactorType)
|
|
ScheduledWfrQty = Schedule_Services('GetScheduledWfrQty', WorkOrder)
|
|
AdjustedDays = Schedule_Services('GetAdjustedDays', WorkOrder, '', EventWfrs)
|
|
If MinutesPerWafer EQ '' then
|
|
Msg(@Window, 'Warning: ' : EpiPart : ' appears to be missing minutes per wafer values for ' : ReactorType)
|
|
end
|
|
end
|
|
|
|
If (WorkOrder NE '') then
|
|
Set_Property(@Window : '.EPI_PART', 'TEXT', EpiPart)
|
|
Set_Property(@Window : '.TOTAL_WAFERS', 'TEXT', TotalWafers)
|
|
Set_Property(@Window : '.TOTAL_REMAINING', 'TEXT', Remaining)
|
|
Set_Property(@Window : '.PERCENT_COMPLETE', 'TEXT', Oconv(Complete, 'MD0[ %]S'))
|
|
// Calculate the end date based on the adjusted days.
|
|
StartDTM = Get_Property(@Window : '.SCHEDULE_START_DTM', 'INVALUE')
|
|
EndDTM = StartDTM + AdjustedDays - 1
|
|
Set_Property(@Window : '.SCHEDULE_END_DTM', 'INVALUE', EndDTM)
|
|
AdjustedDaysRounded = SRP_Math('ROUND', AdjustedDays, 1)
|
|
Set_Property(@Window : '.DAYS', 'DEFPROP', AdjustedDaysRounded)
|
|
end else
|
|
Error_Services('DisplayError')
|
|
Set_Property(@Window : '.EPI_PART', 'TEXT', '')
|
|
Set_Property(@Window : '.TOTAL_WAFERS', 'TEXT', '')
|
|
Set_Property(@Window : '.TOTAL_REMAINING', 'TEXT', '')
|
|
Set_Property(@Window : '.SCHEDULE_WAFERS', 'TEXT', '')
|
|
Set_Property(@Window : '.PERCENT_COMPLETE', 'TEXT', '')
|
|
Set_Property(@Window : '.SCHEDULE_END_DTM', 'INVALUE', '')
|
|
Set_Property(@Window : '.DAYS', 'DEFPROP', '')
|
|
end
|
|
|
|
return
|
|
|
|
|
|
PopulateControls:
|
|
|
|
Set_Property(@Window, 'TEXT', 'Scheduler Actions - Cancel Work Order Event')
|
|
Set_Property(@Window : '.REACTOR_NO', 'NEXT', @Window : '.SCHEDULE_START_DTM')
|
|
Set_Property(@Window : '.DESCRIPTION', 'NEXT', @Window : '.REACTOR_NO')
|
|
WONo = ''
|
|
ScheduleKeyID = ''
|
|
GoSub UpdateScheduleDetails
|
|
GoSub UpdateReactorDetails
|
|
GoSub UpdateCustomerName
|
|
GoSub UpdateWorkOrderDetails
|
|
Set_Property(@Window : '.REACTOR_NO', 'FOCUS', True$)
|
|
|
|
return
|
|
|
|
|