303 lines
12 KiB
Plaintext
303 lines
12 KiB
Plaintext
Compile function NDW_PACKAGING_EVENTS(CtrlEntId, Event, @PARAMS)
|
|
|
|
/***********************************************************************************************************************
|
|
|
|
This program is proprietary and is not to be used by or disclosed to others, nor is it to be copied without written
|
|
permission from Infineon.
|
|
|
|
Name : NDW_Packaging_Events
|
|
|
|
Description : This function acts as a commuter module for all events related to this window.
|
|
|
|
Notes : Commuter Modules are automatically called from the Promoted_Events function which is called by the
|
|
application-specific promoted event handler. This makes it possible to add QuickEvents that need to
|
|
execute Basic+ logic without having use the Form Designer to make the association, although this is
|
|
limited to the events which are currently promoted.
|
|
|
|
If the form needs to call the commuter module directly then the QuickEvent parameters should be
|
|
formatted like this:
|
|
|
|
'@SELF','@EVENT',['@PARAM1','@PARAMx']
|
|
|
|
Parameters :
|
|
CtrlEntId [in] -- The fully qualified name of the control calling the promoted event
|
|
Event [in] -- The event being executed. See the Notes section regarding "PRE" events
|
|
Param1-15 [in] -- Additional event parameter holders
|
|
EventFlow [out] -- Set to 1 or 0 so the calling event knows whether or not to chain forward. See comments in
|
|
EVENT_SETUP insert
|
|
|
|
History : (Date, Initials, Notes)
|
|
10/11/19 djs Created initial commuter module.
|
|
10/07/21 DPC rearranged layout, added delay after Cassette1 scan
|
|
|
|
***********************************************************************************************************************/
|
|
#pragma precomp SRP_PreCompiler
|
|
#window NDW_PACKAGING
|
|
|
|
$insert APP_INSERTS
|
|
$insert EVENT_SETUP
|
|
$insert MSG_EQUATES
|
|
$insert LSL_USERS_EQUATES
|
|
$insert MESSAGE_BOX_EQUATES
|
|
$insert SRP_POPUP_EQUATES
|
|
$INSERT LOGICAL
|
|
|
|
Equ MSG_WIDTH$ to 600
|
|
|
|
Declare subroutine SRP_Show_Window, ErrMsg, Packaging_Services
|
|
Declare function Database_Services, Security_Services, MemberOf, Form_Services, Scan_Services, Packaging_Services
|
|
Declare function Message_Box, SRP_Get_Window_Rect, GetTickCount
|
|
|
|
SubclassInfo = Form_Services('FindSubclassControl')
|
|
Subclass = SubclassInfo<1>
|
|
|
|
// Update the arguments so that the OpenInsight OLE event will treate the ActiveX event as a native event handler.
|
|
If Event EQ 'OLE' then
|
|
Transfer Event to OIEvent
|
|
Transfer Param1 to Event
|
|
Transfer Param2 to Param1
|
|
Transfer Param3 to Param2
|
|
end
|
|
|
|
GoToEvent Event for CtrlEntId else
|
|
// Event not implemented
|
|
end
|
|
|
|
Return EventFlow or 1
|
|
|
|
//-----------------------------------------------------------------------------
|
|
// EVENT HANDLERS
|
|
//-----------------------------------------------------------------------------
|
|
|
|
Event WINDOW.CREATE(CreateParam)
|
|
EventFlow = 1
|
|
End Event
|
|
|
|
|
|
Event EDL_USER_ID_SCAN.LOSTFOCUS(Flag, FocusID)
|
|
If Flag EQ 1 then
|
|
ScanData = Get_Property(CtrlEntID, 'TEXT')
|
|
If ScanData NE '' then
|
|
ScanData = Packaging_Services('ProcessScanData', ScanData, 'EMPLOYEE')
|
|
If Error_Services('NoError') then
|
|
Set_Property(CtrlEntID, 'TEXT', ScanData)
|
|
Set_Property(@Window:'.EDL_CASS_SCAN_1', 'ENABLED', True$)
|
|
Set_Property(@Window:'.EDL_CASS_SCAN_1', 'FOCUS', True$)
|
|
Set_Property(CtrlEntID, 'ENABLED', False$)
|
|
end else
|
|
GoSub ClearForm
|
|
ErrorMessage = Error_Services('GetMessage')
|
|
MsgStruct = ""
|
|
MsgStruct<MTEXTWIDTH$> = MSG_WIDTH$
|
|
Msg(@Window, MsgStruct, 'PROCESS_ERROR', '', ErrorMessage)
|
|
Set_Property(CtrlEntId, 'FOCUS', True$)
|
|
end
|
|
end
|
|
end
|
|
|
|
end event
|
|
|
|
|
|
Event EDL_CASS_SCAN_1.LOSTFOCUS(Flag, FocusID)
|
|
|
|
If Flag EQ 1 then
|
|
ScanData = Get_Property(CtrlEntID, 'TEXT')
|
|
If ScanData NE '' then
|
|
ScanData = Packaging_Services('ProcessScanData', ScanData, 'CASSETTE_1')
|
|
|
|
If Error_Services('NoError') then
|
|
Set_Property(CtrlEntID, 'TEXT', ScanData)
|
|
Set_Property(@Window:'.EDL_POLY_SCAN', 'ENABLED', True$)
|
|
Set_Property(@Window:'.EDL_POLY_SCAN', 'FOCUS', True$)
|
|
Set_Property(CtrlEntID, 'ENABLED', False$)
|
|
end else
|
|
GoSub ClearForm
|
|
ErrorMessage = Error_Services('GetMessage')
|
|
MsgStruct = ""
|
|
MsgStruct<MTEXTWIDTH$> = MSG_WIDTH$
|
|
Msg(@Window, MsgStruct, 'PROCESS_ERROR', '', ErrorMessage)
|
|
Set_Property(@Window:'.EDL_USER_ID_SCAN', 'FOCUS', True$)
|
|
end
|
|
end
|
|
end
|
|
|
|
end event
|
|
|
|
|
|
Event EDL_CASS_SCAN_2.LOSTFOCUS(Flag, FocusID)
|
|
|
|
If Flag EQ 1 then
|
|
ScanData = Get_Property(CtrlEntID, 'TEXT')
|
|
If ScanData NE '' then
|
|
FirstCassID = Get_Property(@Window:'.EDL_CASS_SCAN_1', 'TEXT')
|
|
OperatorID = Get_Property(@Window:'.EDL_USER_ID_SCAN', 'TEXT')
|
|
Sequence1 = Get_Property(@Window:'.EDL_SEQUENCE1', 'TEXT')
|
|
ScanData = Packaging_Services('ProcessScanData', ScanData, 'CASSETTE_2', FirstCassID, OperatorID, Sequence1)
|
|
If Error_Services('NoError') then
|
|
Set_Property(CtrlEntID, 'TEXT', ScanData)
|
|
Set_Property(@Window:'.EDL_PASSWORD_SCAN', 'ENABLED', True$)
|
|
Set_Property(@Window:'.EDL_PASSWORD_SCAN', 'FOCUS', True$)
|
|
Set_Property(CtrlEntID, 'ENABLED', False$)
|
|
end else
|
|
GoSub ClearForm
|
|
ErrorMessage = Error_Services('GetMessage')
|
|
MsgStruct = ""
|
|
MsgStruct<MTEXTWIDTH$> = MSG_WIDTH$
|
|
Msg(@Window, MsgStruct, 'PROCESS_ERROR', '', ErrorMessage)
|
|
Set_Property(@Window:'.EDL_USER_ID_SCAN', 'FOCUS', True$)
|
|
end
|
|
end
|
|
end
|
|
|
|
end event
|
|
|
|
|
|
Event EDL_POLY_SCAN.LOSTFOCUS(Flag, FocusID)
|
|
|
|
If Flag EQ 1 then
|
|
ScanData = Get_Property(CtrlEntID, 'TEXT')
|
|
If ScanData NE '' then
|
|
ScanData = Packaging_Services('ProcessScanData', ScanData, 'POLY')
|
|
If Error_Services('NoError') then
|
|
Set_Property(CtrlEntID, 'TEXT', ScanData)
|
|
Utility("CURSOR", "H")
|
|
//delay for 30 seconds
|
|
Gosub SetDelay
|
|
Utility("CURSOR", "A")
|
|
Set_Property(@Window:'.EDL_TRILAM_SCAN', 'ENABLED', True$)
|
|
Set_Property(@Window:'.EDL_TRILAM_SCAN', 'FOCUS', True$)
|
|
Set_Property(CtrlEntID, 'ENABLED', False$)
|
|
end else
|
|
ScanData = Get_Property(CtrlEntID, 'TEXT')
|
|
If ScanData[1, 3] EQ 'PWD' then Set_Property(CtrlEntID, 'TEXT', '')
|
|
ErrorMessage = Error_Services('GetMessage')
|
|
MsgStruct = ""
|
|
MsgStruct<MTEXTWIDTH$> = MSG_WIDTH$
|
|
Msg(@Window, MsgStruct, 'PROCESS_ERROR', '', ErrorMessage)
|
|
Set_Property(CtrlEntID, 'FOCUS', True$)
|
|
SelectAll = 1:@FM:65534
|
|
Set_Property(CtrlEntID, 'SELECTION', SelectAll)
|
|
end
|
|
end
|
|
end
|
|
|
|
end event
|
|
|
|
|
|
Event EDL_TRILAM_SCAN.LOSTFOCUS(Flag, FocusID)
|
|
|
|
If Flag EQ 1 then
|
|
ScanData = Get_Property(CtrlEntID, 'TEXT')
|
|
If ScanData NE '' then
|
|
ScanData = Packaging_Services('ProcessScanData', ScanData, 'TRILAM')
|
|
If Error_Services('NoError') then
|
|
Set_Property(CtrlEntID, 'TEXT', ScanData)
|
|
Set_Property(@Window:'.EDL_CASS_SCAN_2', 'ENABLED', True$)
|
|
Set_Property(@Window:'.EDL_CASS_SCAN_2', 'FOCUS', True$)
|
|
Set_Property(CtrlEntID, 'ENABLED', False$)
|
|
end else
|
|
ScanData = Get_Property(CtrlEntID, 'TEXT')
|
|
If ScanData[1, 3] EQ 'PWD' then Set_Property(CtrlEntID, 'TEXT', '')
|
|
ErrorMessage = Error_Services('GetMessage')
|
|
MsgStruct = ""
|
|
MsgStruct<MTEXTWIDTH$> = MSG_WIDTH$
|
|
Msg(@Window, MsgStruct, 'PROCESS_ERROR', '', ErrorMessage)
|
|
Set_Property(CtrlEntID, 'FOCUS', True$)
|
|
SelectAll = 1:@FM:65534
|
|
Set_Property(CtrlEntID, 'SELECTION', SelectAll)
|
|
end
|
|
end
|
|
end
|
|
|
|
end event
|
|
|
|
Event EDL_PASSWORD_SCAN.LOSTFOCUS(Flag, FocusID)
|
|
|
|
If Flag EQ 1 then
|
|
ScanData = Get_Property(CtrlEntID, 'TEXT')
|
|
If ScanData NE '' then
|
|
Username = Get_Property(@Window:'.EDL_USER_ID_SCAN', 'TEXT')
|
|
PolyText = Get_Property(@Window:'.EDL_POLY_SCAN', 'TEXT')
|
|
BaggerID = PolyText[5,1]
|
|
ScanData = Packaging_Services('ProcessScanData', ScanData, 'PASSWORD', Username)
|
|
If Error_Services('NoError') then
|
|
Set_Property(CtrlEntID, 'TEXT', ScanData)
|
|
// Complete packaging
|
|
CassetteID = Get_Property(@Window:'.EDL_CASS_SCAN_1', 'TEXT')
|
|
//replace period with asterisk for GaN cassettes
|
|
Convert '.' to '*' in CassetteID
|
|
OperatorID = Get_Property(@Window:'.EDL_USER_ID_SCAN', 'TEXT')
|
|
Packaging_Services('CompletePackaging', CassetteID, OperatorID, BaggerID)
|
|
If Error_Services('NoError') then
|
|
SuccessMessage = 'Bagging process complete!'
|
|
MsgStruct = ""
|
|
MsgStruct<MTEXTWIDTH$> = MSG_WIDTH$
|
|
Msg(@Window, MsgStruct, 'PROCESS_COMPLETE', '', SuccessMessage)
|
|
end else
|
|
ErrorMessage = 'An internal error occurred. Please retry the pack scan.'
|
|
MsgStruct = ""
|
|
MsgStruct<MTEXTWIDTH$> = MSG_WIDTH$
|
|
Msg(@Window, MsgStruct, 'PROCESS_ERROR', '', ErrorMessage)
|
|
end
|
|
|
|
GoSub ClearForm
|
|
|
|
end else
|
|
ErrorMessage = Error_Services('GetMessage')
|
|
MsgStruct = ""
|
|
MsgStruct<MTEXTWIDTH$> = MSG_WIDTH$
|
|
Msg(@Window, MsgStruct, 'PROCESS_ERROR', '', ErrorMessage)
|
|
Set_Property(CtrlEntID, 'FOCUS', True$)
|
|
SelectAll = 1:@FM:65534
|
|
Set_Property(CtrlEntID, 'SELECTION', SelectAll)
|
|
end
|
|
end
|
|
end
|
|
|
|
end event
|
|
|
|
|
|
Event PUB_CLEAR_FORM.CLICK()
|
|
|
|
GoSub ClearForm
|
|
|
|
end event
|
|
|
|
|
|
////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
|
|
// Internal GoSubs
|
|
////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
|
|
|
|
ClearForm:
|
|
|
|
Set_Property(@Window:'.EDL_SEQUENCE1' , 'TEXT' , '')
|
|
Set_Property(@Window:'.EDL_USER_ID_SCAN' , 'TEXT' , '')
|
|
Set_Property(@Window:'.EDL_CASS_SCAN_1' , 'TEXT' , '')
|
|
Set_Property(@Window:'.EDL_CASS_SCAN_2' , 'TEXT' , '')
|
|
Set_Property(@Window:'.EDL_POLY_SCAN' , 'TEXT' , '')
|
|
Set_Property(@Window:'.EDL_TRILAM_SCAN' , 'TEXT' , '')
|
|
Set_Property(@Window:'.EDL_PASSWORD_SCAN' , 'TEXT' , '')
|
|
Set_Property(@Window:'.EDL_USER_ID_SCAN' , 'ENABLED', True$)
|
|
Set_Property(@Window:'.EDL_CASS_SCAN_1' , 'ENABLED', -1)
|
|
Set_Property(@Window:'.EDL_CASS_SCAN_2' , 'ENABLED', -1)
|
|
Set_Property(@Window:'.EDL_POLY_SCAN' , 'ENABLED', -1)
|
|
Set_Property(@Window:'.EDL_TRILAM_SCAN' , 'ENABLED', -1)
|
|
Set_Property(@Window:'.EDL_PASSWORD_SCAN' , 'ENABLED', -1)
|
|
Set_Property(@Window:'.PUB_COMPLETE_BAGGING' , 'ENABLED', -1)
|
|
Set_Property(@Window:'.EDL_USER_ID_SCAN', 'FOCUS', True$)
|
|
|
|
return
|
|
|
|
SetDelay:
|
|
|
|
If Not(Memberof(@User4, 'OI_ADMIN')) then
|
|
StartTime = GetTickCount()
|
|
Loop
|
|
TimeElapsed = GetTickCount() - StartTime
|
|
Until TimeElapsed GT 30000 ; // Note: 30000 ms = 30 s
|
|
Repeat
|
|
end
|
|
|
|
return
|
|
|