Compile function NCR_Services(@Service, @Params)
#pragma precomp SRP_PreCompiler
/***********************************************************************************************************************
Name : NCR_Services
Description : Handler program for all NCR services.
Notes : Application errors should be logged using the Error Services module. There are a few methodological
assumptions built into way errors are managed which are important to understand in order to properly
work with Error Services:
- The term 'top' refers to the originating procedure of a call stack and the term 'bottom' refers to
the last routine (or the current routine) within a call stack. Within the OpenInsight Debugger
this will appear backwards since the originating procedure always appears at the bottom of the
list and the current routine appears at the top of the list. We are using this orientation because
it is common to refer to the process of calling other procedures as 'drilling down'.
- The reason for defining the orientation of the call stack is because Error_Services allows for
multiple error conditions to be appended to an original error. In most cases this will happen when
a procedure at the bottom of the stack generates an error condition and then returns to its
calling procedure. This higher level procedure can optionally add more information relevant to
itself. This continues as the call stack 'bubbles' its way back to the top to where the
originating procedure is waiting.
- Native OpenInsight commands that handle errors (e.g., Set_Status, Set_FSError, Set_EventStatus)
preserve their error state until explicitly cleared. This can hinder the normal execution of code
since subsequent procedures (usually SSPs) will fail if a pre-existing error condition exists.
Our philosophy is that error conditions should automatically be cleared before a new procedure
is executed to avoid this problem. However, the nature of Basic+ does not make this easy to
automate for any given stored procedure. Therefore, if a stored procedure wants to conform to our
philosophy then it should include a call into the 'Clear' service request at the top of the
program. Alternatively this can be done through a common insert (see SERVICE_SETUP for example.)
- Service modules will use the SERVICE_SETUP insert and therefore automatically clear out any
error conditions that were set before.
Parameters :
Service [in] -- Name of the service being requested
Param1-10 [in/out] -- Additional request parameter holders
Response [out] -- Response to be sent back to the Controller (MCP) or requesting procedure
Metadata :
History : (Date, Initials, Notes)
08/29/24 djm Add ProcessScanData service and Service header.
***********************************************************************************************************************/
$insert APP_INSERTS
$Insert SERVICE_SETUP
$Insert NCR_EQUATES
$Insert REACTOR_EQUATES
Declare subroutine Set_Status, Logging_Services, Error_Services, Obj_Notes, Set_Property, Obj_Wo_Mat, Hold_Services
Declare subroutine Btree.Extract, SRP_JSon
Declare function Environment_Services, Logging_Services, SRP_Datetime, Utility, Scan_Services, Error_Services
Declare function Database_Services, Signature_Services, Epipro_Services, Rds_Services, Memberof, Datetime
Declare function Get_Property, SRP_Json, obj_ncr
EQU COL$RDS_NO TO 1
EQU COL$REACTOR TO 2
EQU COL$REJ_CNT TO 3
GoToService
Return Response or ""
////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
// Service Parameter Options
////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
Options SCAN_TYPES = 'CASSETTE_1', 'CASSETTE_2', 'WM_IN_1', 'WM_IN_2'
//----------------------------------------------------------------------------------------------------------------------
// SERVICES
//----------------------------------------------------------------------------------------------------------------------
//----------------------------------------------------------------------------------------------------------------------
// ProcessScanData
//
// ScanData - [Required]
// ScanType - [Required]
// FirstCassID - [Required]
// OperatorID - [Required]
//
// Returns the current stage of a lot. Replaces CURR_STAGE calculated column.
//----------------------------------------------------------------------------------------------------------------------
Service ProcessScanData(ScanData, ScanType = SCAN_TYPES, FirstCassID, OperatorID)
If (ScanData NE '') then
Convert @Lower.Case to @Upper.Case in ScanData
// Code 3of9 encodes the asterisk and underscore characters. These need to be decoded.
ScanData = Scan_Services('DecodeScanData', ScanData)
If Error_Services('NoError') then
ColumnIndex = ''
ColumnValue = ''
// Identify the scan data based on the data identifier prefix (if any). Otherwise, assume this is a
// type of cassette ID (i.e., RDS or WMO).
Begin Case
Case ScanType EQ 'WM_IN_1'
ValidCassID = False$
cnt = Count(ScanData, '|')
if cnt NE 0 then
Error_Services('Add', 'Wrong label - Scan 2D Top Label')
return
end else
CassetteID = ScanData
Swap 'FDI' with '' in CassetteID
Swap '^FS' with '' in CassetteID
Swap 'I' with '' in CassetteID
Convert '.' to '*' in CassetteID
WMIRow = Database_Services('ReadDataRow', 'WM_IN', CassetteID)
If Error_Services('NoError') then
ValidCassID = True$
end
ScanData = CassetteID
If ScanData NE FirstCassID then
Error_Services('Add', 'Lot Label does not match the expected lot in OI. | Please correct this issue and then retry.')
end
end
If ValidCassID EQ False$ then
Error_Services('Add', 'Unrecognized scan data: ':ScanData)
end
Response = ScanData
Case ScanType EQ 'WM_IN_2'
ValidCassID = False$
ScanMismatch = False$
cnt = Count(ScanData, '|')
if cnt NE 0 then
Error_Services('Add', 'Wrong label - Scan 2D Bottom Label')
return
end else
CassetteID = ScanData
Swap 'FDI' with '' in CassetteID
Swap '^FS' with '' in CassetteID
Swap 'I' with '' in CassetteID
Convert '.' to '*' in CassetteID
WMIRow = Database_Services('ReadDataRow', 'WM_IN', CassetteID)
If Error_Services('NoError') then
ValidCassID = True$
end
ScanData = CassetteID
If ScanData NE FirstCassID then
ScanMismatch = True$
end
end
If ScanMismatch EQ True$ then
ValidCassID = False$
If (RowExists('WM_IN', FirstCassID) EQ True$) And (RowExists('WM_IN', CassetteID) EQ True$) then
// Place first cassette on hold
WONo = Field(FirstCassID, '*', 1, 1)
CassNo = Field(FirstCassID, '*', 3, 1)
HoldEntity = 'WM_IN'
HoldEntityID = FirstCassID
WOMatKey = WONo:'*':CassNo
CtrlEntID = 'NCR_SERVICES' ;* Control checked/unchecked
OriginFlag = '' ;* Flag to indicate a hold initiated from the packagaing form
HoldData = ''
HoldData<1> = OperatorID
HoldData<2> = 'Lot placed on hold due to NCR Barcode verification mismatch.'
HoldData<3> = False$
Hold_Services('OnHold', WOMatKey, HoldEntity, HoldEntityID, 'HOLD', HoldData, OperatorID)
// Place Second cassette on hold
WONo = Field(CassetteID, '*', 1, 1)
CassNo = Field(CassetteID, '*', 3, 1)
HoldEntity = 'WM_IN'
HoldEntityID = CassetteID
WOMatKey = WONo:'*':CassNo
CtrlEntID = 'NCR_SERVICES' ;* Control checked/unchecked
OriginFlag = '' ;* Flag to indicate a hold initiated from the packagaing form
HoldData = ''
HoldData<1> = OperatorID
HoldData<2> = 'Lot placed on hold due to NCR Barcode verification mismatch.'
HoldData<3> = False$
Hold_Services('OnHold', WOMatKey, HoldEntity, HoldEntityID, 'HOLD', HoldData, OperatorID)
Message = 'NCR Label verification failed due to mismatched barcodes. Both cassettes placed on hold - Supervisor, Lead, or Engineering disposition required.':CRLF$ |
: 'WM_IN Label #1: ':FirstCassID:CRLF$ |
: 'WM_IN Label #2: ':CassetteID:CRLF$ |
: 'Operator: ':OperatorID
Error_Services('Add', Message)
end else
Error_Services('Add', 'Unrecognized scan data: ':ScanData)
end
end
If ValidCassID EQ False$ then
Error_Services('Add', 'Unrecognized scan data: ':ScanData)
end
Response = ScanData
Case ScanType EQ 'CASSETTE_1'
// Assume this is intended to be a Cassette ID scan (either WMO or RDS). Only if this is a
// non-existent carrier will the scan data be considered invalid.
cnt = DCount(ScanData, '|')
if cnt NE 8 then
CassetteID = 0
Error_Services('Add', 'Wrong label - Scan 2D Top Label')
return
end else
// RDS should be 3rd position
CassetteID = Field(ScanData, '|', 3)
Seq1 = Field(ScanData, '|', 8)
end
// Strip '1T', 'I', and 'O' prefixes.
If CassetteID[1, 2] EQ '1T' then
CassetteID[1, 2] = ''
If ((CassetteID[1, 1] EQ 'O') or (CassetteID[1, 1] EQ 'I')) then CassetteID[1, 1] = ''
end
If ( (CassetteID[1, 1] EQ 'O') or (CassetteID[1, 1] EQ 'I') ) then CassetteID[1, 1] = ''
ValidCassID = False$ ; // Assume Cassette ID is not valid for now.
RDSCass = Count(CassetteID, '.') EQ 0 AND Num(CassetteID)
GaNCass = Count(CassetteID, '.') EQ 1 AND not(RDSCass)
EPPCass = Count(CassetteID, '.') EQ 2 AND not(RDSCass) AND not(GaNCass)
Begin Case
Case GaNCass
Convert '.' to '*' in CassetteID
WOMatRow = Database_Services('ReadDataRow', 'WO_MAT', CassetteID)
If Error_Services('NoError') then
ValidCassID = True$
end
Case EPPCass
Convert '.' to '*' in CassetteID
WMOutRow = Database_Services('ReadDataRow', 'WM_OUT', CassetteID)
If Error_Services('NoError') then
ValidCassID = True$
end
Case RDSCass
RDSRow = Database_Services('ReadDataRow', 'RDS', CassetteID)
If Error_Services('NoError') then
ValidCassID = True$
end
End Case
If ( (Seq1 EQ 'SEQ1') or (Seq1 EQ 'SEQ2') ) then
Set_Property(@Window, '@SEQ1', Seq1)
end else
Error_Services('Add', 'Error reading sequence information')
end
If ValidCassID EQ False$ then
Error_Services('Add', 'Unrecognized scan data: ':ScanData)
end
ScanData = CassetteID
If ScanData NE FirstCassID then
Error_Services('Add', 'Lot Label does not match the expected lot in OI. | Please correct this issue and then retry.')
end
Response = ScanData
Case ScanType EQ 'CASSETTE_2'
// Assume this is intended to be a Cassette ID scan (either WMO or RDS). Only if this is a
// non-existent carrier will the scan data be considered invalid.
cnt = DCount(ScanData, '|')
if cnt NE 8 then
CassetteID = 0
Error_Services('Add', 'Wrong label - Scan 2D Bottom Label')
return
end else
// RDS should be 3rd position
SecondCassID = Field(ScanData, '|', 3)
Seq2 = Field(ScanData, '|', 8)
end
// Strip '1T', 'I', and 'O' prefixes.
If SecondCassID[1, 2] EQ '1T' then
SecondCassID[1, 2] = ''
If ( (SecondCassID[1, 1] EQ 'O') or (SecondCassID[1, 1] EQ 'I') ) then SecondCassID[1, 1] = ''
end
If ( (SecondCassID[1, 1] EQ 'O') or (SecondCassID[1, 1] EQ 'I') ) then SecondCassID[1, 1] = ''
ValidCassID = False$ ; // Assume Cassette ID is not valid for now.
ScanMismatch = False$
SeqMismatch = False$
SeqError = False$
Convert '*' to '.' in FirstCassID
If Error_Services('NoError') then
ValidCassID = True$
If (SecondCassID NE FirstCassID) then
ScanMismatch = True$
end else
Seq1 = Get_Property(@Window, '@SEQ1')
Begin Case
Case ( (Seq2 NE 'SEQ1') and (Seq2 NE 'SEQ2') )
SeqError = True$
Case (Seq2 EQ Seq1)
SeqMismatch = True$
End Case
end
end
If ValidCassID EQ False$ then Error_Services('Add', 'Unrecognized scan data: ':ScanData)
If (ScanMismatch EQ True$) AND (ValidCassID EQ True$) then
// Check if first cassette ID is a valid RDS or WM_OUT key
Convert '.' to '*' in FirstCassID
ValidCassID = False$
Begin Case
Case ( RowExists('RDS', FirstCassID) EQ True$ )
ValidCassID = True$
WONo = Xlate('RDS', FirstCassID, 'WO', 'X')
CassNo = Xlate('RDS', FirstCassID, 'CASS_NO', 'X')
HoldEntity = 'RDS'
Case ( RowExists('WM_OUT', FirstCassID) EQ True$ )
ValidCassID = True$
WONo = Field(FirstCassID, '*', 1, 1)
CassNo = Field(FirstCassID, '*', 3, 1)
HoldEntity = 'WM_OUT'
Case ( RowExists('WM_IN', FirstCassID) EQ True$ )
ValidCassID = True$
WONo = Field(FirstCassID, '*', 1, 1)
CassNo = Field(FirstCassID, '*', 3, 1)
HoldEntity = 'WM_IN'
Case ( RowExists('WO_MAT', FirstCassID) EQ True$ )
ValidCassID = True$
WONo = Field(FirstCassID, '*', 1, 1)
CassNo = Field(FirstCassID, '*', 2, 1)
HoldEntity = 'WO_MAT'
Case Otherwise$
Null
End Case
HoldEntityID = FirstCassID
// Place first cassette on hold
WOMatKey = WONo:'*':CassNo
CtrlEntID = 'NCR_SERVICES' ;* Control checked/unchecked
OriginFlag = '' ;* Flag to indicate a hold initiated from the packagaing form
HoldData = ''
HoldData<1> = OperatorID
HoldData<2> = 'Lot placed on hold due to NCR Barcode verification mismatch.'
HoldData<3> = False$
Hold_Services('OnHold', WOMatKey, HoldEntity, HoldEntityID, 'HOLD', HoldData, OperatorID)
// Check if second cassette ID is a valid RDS or WM_OUT key
Convert '.' to '*' in SecondCassID
ValidCassID = False$
Begin Case
Case ( RowExists('RDS', SecondCassID) EQ True$ )
ValidCassID = True$
WONo = Xlate('RDS', SecondCassID, 'WO', 'X')
CassNo = Xlate('RDS', SecondCassID, 'CASS_NO', 'X')
HoldEntity = 'RDS'
ValidCassID = True$
Case ( RowExists('WM_OUT', SecondCassID) EQ True$ )
ValidCassID = True$
WONo = Field(SecondCassID, '*', 1, 1)
CassNo = Field(SecondCassID, '*', 3, 1)
HoldEntity = 'WM_OUT'
Case ( RowExists('WM_IN', SecondCassID) EQ True$ )
WONo = Field(SecondCassID, '*', 1, 1)
CassNo = Field(SecondCassID, '*', 3, 1)
HoldEntity = 'WM_IN'
ValidCassID = True$
Case ( RowExists('WO_MAT', SecondCassID) EQ True$ )
WONo = Field(SecondCassID, '*', 1, 1)
CassNo = Field(SecondCassID, '*', 2, 1)
HoldEntity = 'WO_MAT'
ValidCassID = True$
Case Otherwise$
Null
End Case
If ValidCassID EQ True$ then
HoldEntityID = SecondCassID
WOMatKey = WONo:'*':CassNo
// Place second cassette on hold
CtrlEntID = 'NCR_SERVICES' ;* Control checked/unchecked
OriginFlag = '' ;* Flag to indicate a hold initiated from the packagaing form
HoldData = ''
HoldData<1> = OperatorID
HoldData<2> = 'Lot placed on hold due to NCR Barcode verification mismatch.'
HoldData<3> = False$
Hold_Services('OnHold', WOMatKey, HoldEntity, HoldEntityID, 'HOLD', HoldData, OperatorID)
end
Message = 'NCR Label verification failed due to mismatched barcodes. Both cassettes placed on hold - Supervisor, Lead, or Engineering disposition required.':CRLF$ |
: 'Cassette Label #1: ':FirstCassID:CRLF$ |
: 'Cassette Label #2: ':SecondCassID:CRLF$ |
: 'Operator: ':OperatorID
Error_Services('Add', Message)
end else if (SeqMismatch EQ True$) then
//do sequence mismatch stuff here
Message = 'NCR Label verification failed due to operator double-scanning barcode.':CRLF$ |
: 'Cassette: ':FirstCassID:CRLF$ |
: 'Operator: ':OperatorID
Error_Services('Add', Message)
end else if (SeqError EQ True$) then
Error_Services('Add', 'Error reading sequence information')
end
ScanData = ''
ScanData = SecondCassID
Response = ScanData
End Case
end
end else
Error_Services('Add', 'ScanData argument was missing in the ' : Service : ' service.')
end
end service
Service SendToSPC(NCRNo, RDSList, ReactorType, PSNo, DeptResp, LossCode, LossDesc, LossStage, LossBy, ACCode, ACDesc)
Headers = 'Logging DTM' : @FM : 'Machine' : @FM : 'Level' : @FM : 'Log'
ColumnWidths = 20 : @FM : 12 : @FM : 7 : @FM : 500
Machine = Environment_Services('GetServer')
LogPath = Environment_Services('GetApplicationRootPath') : '\LogFiles\NCR'
makeDirSuccess = Utility("MAKEDIR", LogPath)
LogDate = Oconv(Date(), 'D4/')
LogFileName = LogDate[7, 4] : '-' : LogDate[1, 2] : '-' : LogDate[4, 2] : '_NcrSendToSpc.csv'
objLog = Logging_Services('NewLog', LogPath, LogFileName, CRLF$, ' ', Headers, ColumnWidths, False$, False$)
RdsNos = ''
RdsCount = 0
ReactorList = ''
ReactorCount = 0
RejCntList = ''
RejCntCount = 0
RDSCnt = DCOUNT(RDSList<1>,@VM)
If RDSCnt GT 0 then
FOR I = 1 TO RDSCnt
If RdsNos NE '' then
RdsNos := ', '
end
RdsNos := RDSList<COL$RDS_NO, I>
RdsCount += Num(RDSList<COL$RDS_NO, I>)
If ReactorList NE '' then
ReactorList := ', '
end
ReactorList := RDSList<COL$REACTOR, I>
ReactorCount += Num(RDSList<COL$REACTOR, I>)
If RejCntList NE '' then
RejCntList := ', '
end
RejCntList := RDSList<COL$REJ_CNT, I>
RejCntCount += Num(RDSList<COL$REJ_CNT, I>)
Next I
end
LogMessage = 'Attempting to send NCR data to SPC. Data: {'
LogMessage := 'NCR No: ' : NCRNo
LogMessage := ', RDS Nos: ' : RdsNos
LogMessage := ', Reactors: ' : ReactorList
LogMessage := ', Reject Counts: ' : RejCntList
LogMessage := ', Reactor Type: ' : ReactorType
LogMessage := ', PSN: ' : PSNo
LogMessage := ', Responsible Dept: ' : DeptResp
LogMessage := ', Loss Code: ' : LossCode
LogMessage := ', Loss Desc: ' : LossDesc
LogMessage := ', Loss Stage: ' : LossStage
LogMessage := ', Loss By: ' : LossBy
LogMessage := ', AC Code: ' : ACCode
LogMessage := ', AC Desc: ' : ACDesc
LogMessage := '}'
LogDate = Oconv(Date(), 'D4/')
LogData = ''
LogData<1> = Oconv(Date(), 'D4/') : ' ' : Oconv(Time(), 'MTS') ; // Logging DTM
LogData<2> = Machine
LogData<3> = 'INFO'
LogData<4> = LogMessage
Logging_Services('AppendLog', objLog, LogData, @RM, @FM, False$)
ArgsNotNull = NCRNo NE '' and RDSList NE '' and ReactorType NE '' and PSNo NE ''
ArgsNotNull = ArgsNotNull EQ True$ and DeptResp NE '' and LossCode NE ''
ArgsNotNull = ArgsNotNull EQ True$ and LossDesc NE '' and LossStage NE ''
ArgsNotNull = ArgsNotNull EQ True$ and LossBy NE '' and ACCode NE '' and ACDesc NE ''
RdsListCountsAtLeastOne = RdsCount GE 1 and ReactorCount GE 1 and RejCntCount GE 1
RdsListCountsEqual = RdsCount EQ ReactorCount and ReactorCount EQ RejCntCount
If ArgsNotNull EQ True$ and RdsListCountsAtLeastOne NE False$ and RdsListCountsEqual NE False$ then
DataLines = ''
FOR I = 1 TO RDSCnt
DataLine = QUOTE(NCRNo):TAB$
DataLine := QUOTE(RDSList<COL$RDS_NO, I>):TAB$
IF ReactorType = 'P' OR ReactorType = 'EPP' THEN
DataLine := QUOTE('EP':RDSList<COL$REACTOR, I>):TAB$ ;* EpiPRO reactors in SPC have "EP" on the front.
END ELSE
DataLine := QUOTE(RDSList<COL$REACTOR, I>):TAB$
END
DataLine := QUOTE(RDSList<COL$REJ_CNT, I>):TAB$
DataLine := QUOTE(PSNo):TAB$
DataLine := QUOTE(DeptResp):TAB$
DataLine := QUOTE(LossCode):TAB$
DataLine := QUOTE(LossDesc):TAB$
DataLine := QUOTE(LossStage):TAB$
DataLine := QUOTE(LossBy):TAB$
DataLine := QUOTE(ACCode):TAB$
DataLine := QUOTE(ACDesc):TAB$
DataLines := DataLine:CRLF$
NEXT I
DateTime = SRP_Datetime("Now")
Year = SRP_Datetime("Year", DateTime)
Month = SRP_Datetime("Month", DateTime)
Day = SRP_Datetime("Day", DateTime)
FileName = NCRNo : '_NCR_Data_' : Year : Month : Day : '.txt'
Path = Environment_Services('GetSPCDataPath')
DOSFile = Path : '\' : FileName
Set_Status(0)
OSRead DOSRecord FROM DOSFile ELSE
ErrCode = Status()
IF ErrCode = 4 THEN
DOSRecord = '' ;* File doesn't exist
END ELSE
* ErrMsg('Unable to read DOS file "SPC_Data.TXT" for update. ':ErrCode:' Please try again.') ;* Remarked out per Chad Becker request - dkk 12/9/14
RETURN
END
END
DOSRecord := DataLines
OSWrite DOSRecord ON DOSFile
ErrCode = Status()
ErrorMessage = ''
Begin Case
Case ErrCode EQ 1
ErrorMessage = 'Bad filename.'
Case ErrCode EQ 2
ErrorMessage = 'Cannot write to file. Access denied.'
Case ErrCode EQ 3
ErrorMessage = 'Disk or directory full.'
Case ErrCode EQ 4
ErrorMessage = 'File does not exist.'
Case ErrCode EQ 5
ErrorMessage = 'Unknown error.'
Case ErrCode EQ 6
ErrorMessage = 'Attempt to write to a read-only file.'
End Case
LogDate = Oconv(Date(), 'D4/')
LogData = ''
LogData<1> = Oconv(Date(), 'D4/') : ' ' : Oconv(Time(), 'MTS') ; // Logging DTM
LogData<2> = Machine
If ErrorMessage NE '' then
ErrorMessage = 'Error in ' : Service : '. When attempting to write the NCR data to a file the following error occurred. ' : ErrorMessage
LogData<3> = 'ERROR'
LogData<4> = ErrorMessage
Logging_Services('AppendLog', objLog, LogData, @RM, @FM, False$)
Error_Services('Add', ErrorMessage)
end else
LogData<3> = 'INFO'
LogData<4> = 'Sucessfully sent NCR ' : NCRNo : ' data to SPC in file ' : DOSFile : '.'
Logging_Services('AppendLog', objLog, LogData, @RM, @FM, False$)
end
end else
ErrorMessage = 'Error in ' : Service : '. One or more arguments were null or malformed.'
LogDate = Oconv(Date(), 'D4/')
LogData = ''
LogData<1> = Oconv(Date(), 'D4/') : ' ' : Oconv(Time(), 'MTS') ; // Logging DTM
LogData<2> = Machine
LogData<3> = 'ERROR'
LogData<4> = ErrorMessage
Logging_Services('AppendLog', objLog, LogData, @RM, @FM, False$)
Error_Services('Add', ErrorMessage)
end
end service
Service GetOpenNCRKeys()
table = "NCR"
ErrorMessage = ''
RDSRecords = ''
Open "DICT ":table To @DICT Else
ErrorMessage = 'Error opening NCR dictionary'
End
If ErrorMessage EQ '' then
srch_strng = "STATUS":@VM:'O':@FM
option = ""
flag = ""
Btree.Extract(srch_strng, table, @DICT, RDSRecords, option, flag)
If Flag NE 0 then
ErrorMessage = 'Error performing BTree Extract on NCR table.'
end
end
If ErrorMessage NE '' then
Error_Services('Add', ErrorMessage)
end
Response = RDSRecords
end service
Service ConvertRecordToJson(NCRId)
NCRJson = ''
ErrorMessage = ''
If RowExists('NCR', NCRId) then
NCRRecord = Database_Services('ReadDataRow', 'NCR', NCRId, True$, 0, False$)
If Error_Services('NoError') then
objNCR = ''
If SRP_JSON(objNCR, 'New', 'Object') then
SRP_JSON(objNCR, 'SetValue', 'NCRId', NCRId)
ThisNCREntryDate = NCRRecord<NCR_ENTRY_DATE$>
ThisNCREntryTime = NCRRecord<NCR_ENTRY_TIME$>
If ThisNCREntryTime EQ '' then ThisNCREntryTime = 0
ThisNCREntryDateTime = OConv(SRP_DateTime('Combine', ThisNCREntryDate, ThisNCREntryTime), 'DT')
SRP_JSON(objNCR, 'SetValue', 'EntryDateTime', ThisNCREntryDateTime, 'String')
SRP_JSON(objNCR, 'SetValue', 'Shift', NCRRecord<NCR_SHIFT$>)
ThisNCRReactorNo = NCRRecord<NCR_REACTOR$>
SRP_JSON(objNCR, 'SetValueArray', 'Reactor', ThisNCRReactorNo, @VM);//This needs to be a list to support EpiPro
ThisNCRCassId = ''
ThisNCRReactorType = Xlate('REACTOR', ThisNCRReactorNo, REACTOR_REACT_TYPE$, 'X')
If ThisNCRReactorType NE 'EPP' then
ThisNCRCassId = NCRRecord<NCR_RDS_ID$>
end else
ThisNCRWONo = NCRRecord<NCR_WO_NO$>
ThisNCRStepNo = NCRRecord<NCR_WO_STEP$>
ThisNCRCassNo = NCRRecord<NCR_WO_MAT_CASS_NO$>
ThisNCRCassId = ThisNCRWONo : '-' : ThisNCRStepNo : '-' : ThisNCRCassNo
end
SRP_JSON(objNCR, 'SetValueArray', 'CassetteId', ThisNCRCassId, @VM)
SRP_JSON(objNCR, 'SetValue', 'LossStage', NCRRecord<NCR_LOSS_STAGE$>)
ThisNCRRejectCount = 0
ThisNCRRejectCount = Obj_Ncr('RejQty', NCRId:@RM:NCRRecord)
SRP_JSON(objNCR, 'SetValueArray', 'TotalRejected', ThisNCRRejectCount, @VM)
SRP_JSON(objNCR, 'SetValue', 'LossComments', NCRRecord<NCR_LOSS_COMMENTS$>)
NCRJson = SRP_JSON(objNCR, 'Stringify', 'Styled')
SRP_JSON(objNCR, 'Release')
end else
ErrorMessage = 'Error creating NCR Json Object'
end
end else
ErrorMessage = Error_Services('GetMessage')
end
end else
ErrorMessage = 'Non-existent NCR Id passed to routine'
end
If ErrorMessage NE '' then
Error_Services('Add', ErrorMessage)
end
Response = NCRJson
end service