open-insight/LSL2/STPROC/COMM_RDS_SHIP.txt
Infineon\StieberD 7762b129af pre cutover push
2024-09-04 20:33:41 -07:00

175 lines
3.5 KiB
Plaintext

COMPILE FUNCTION Comm_RDS_Ship(Method, Parm1, Parm2)
/*
Commuter module for existing RDS... windows.
Used for added functionality in the RDS Mess.
09/17/2004 - John C. Henry, J.C. Henry & Co., Inc.
*/
DECLARE SUBROUTINE Set_Property, End_Dialog, Send_Event, Set_Status, ErrMsg, Security_Err_Msg
DECLARE SUBROUTINE obj_Appwindow, Start_Window, Msg, Start_Window, End_Window, obj_WO_Step
DECLARE FUNCTION Get_Property, Get_Status, Dialog_Box, Utility, Send_Message, Popup, obj_RDS_Makeup, Msg, obj_RDS
DECLARE FUNCTION Security_Check,obj_WO_Step
EQU CRLF$ TO \0D0A\
$INSERT APPCOLORS
$INSERT MSG_EQUATES
$INSERT RDS_EQU
$INSERT POPUP_EQUATES
$INSERT LSL_USERS_EQU
$INSERT SECURITY_RIGHTS_EQU
ErrTitle = 'Error in Comm_RDS'
ErrorMsg = ''
Result = ''
BEGIN CASE
CASE Method = 'Create' ; GOSUB Create
CASE Method = 'Clear' ; GOSUB Clear
CASE Method = 'Refresh' ; GOSUB Refresh
CASE Method = 'LURds' ; GOSUB LURds
CASE Method = 'ClearShipment' ; GOSUB ClearShipment
CASE 1
ErrMsg(ErrTitle:@SVM:'Unknown method ':QUOTE(Method):' passed to routine.')
END CASE
RETURN Result
* * * * * * *
Create:
* * * * * * *
IF NOT(Security_Check('COC',READ$)) THEN
Security_Err_Msg('COC',READ$)
End_Window(@WINDOW)
RETURN
END
obj_Appwindow('Create')
Def = ""
Def<MTEXT$> = "Enter Shipment Number to clear:"
Def<MTYPE$> = "RCE"
Def<MICON$> = "?"
ShipNo = Msg(@window, Def)
IF ShipNo = CHAR(27) OR ShipNo = '' THEN
Send_Event(@WINDOW,'CLOSE')
RETURN
END
ShipRec = XLATE('COC',ShipNo,'','X')
IF ShipRec = '' THEN
ErrMsg('Invalid Shipment Number')
*Send_Event(@WINDOW,'CLOSE')
*RETURN
END
Set_Property(@WINDOW,'@SHIP_NO',ShipNo)
GOSUB Refresh
RETURN
* * * * * * *
Clear:
* * * * * * *
* * * * * * *
Refresh:
* * * * * * *
RETURN
* * * * * * *
LURds:
* * * * * * *
WONo = Get_Property(@Window:'.WO', 'TEXT')
WONo = Get_Property(@Window:'.WO', 'TEXT')
RDSKeys = Dialog_Box('NDW_RDS_QUERY', @Window, WONo : @FM : 'quick')
CONVERT @FM TO @VM IN RDSKeys
TypeOver = ''
TypeOver<PDISPLAY$> = RDSKeys
NewRdsNos = Popup(@WINDOW,TypeOver,'WO_LOG_RTS')
IF Get_Status(errCode) THEN
ErrMsg(errCode)
END
IF INDEX(NewRdsNos,@VM,1) THEN
Send_Event(@WINDOW,'QBFINIT')
Set_Property(@WINDOW,'QBFLIST',NewRdsNos)
Send_Event(@WINDOW,'QBFFIRST')
END ELSE
obj_Appwindow('LoadFormKeys',@WINDOW:@RM:NewRdsNos) ;* Load key into form and triggers READ event or places focus on 1st empty key field.
END
RETURN
* * * * * * *
ClearShipment:
* * * * * * *
ShipNo = Get_Property(@WINDOW,'@SHIP_NO')
RDSShipNo = Get_Property(@WINDOW:'.SHIP_NO','TEXT')
RDSNo = Get_Property(@WINDOW:'.RDS_NO','TEXT')
IF Get_Property(@WINDOW,'QBFLIST') NE '' THEN QBFActive = 1 ELSE QBFActive = 0
IF RDSShipNo = ShipNo OR RDSShipNo = '' THEN
Set_Property(@WINDOW:'.SHIP_NO','DEFPROP','')
Set_Property(@WINDOW:'.SHIP_DATE','DEFPROP','')
Set_Property(@WINDOW:'.SHIP_TIME','DEFPROP','')
Set_Property(@WINDOW:'.STATUS','VALUE','R')
Send_Event(@WINDOW,'WRITE')
RDSRec = XLATE('RDS',RDSNo,'','X')
WOStepKey = RDSRec<RDS_WO_STEP_KEY$>
IF WOStepKey NE '' THEN
CurrStatus = obj_RDS('CurrStatus',RDSNo:@RM:RDSRec)
obj_WO_Step('RDSStatus',WOStepKey:@RM:RDSNo:@RM:CurrStatus)
END
IF QBFActive = 1 THEN
Send_Event(@WINDOW,'QBFNEXT')
END
END ELSE
IF QBFActive = 1 THEN
Send_Event(@WINDOW,'QBFNEXT')
END ELSE
Send_Event(@WINDOW,'CLEAR')
END
END
RETURN: