Function WO_LOG_Actions(Action, CalcColName, FSList, Handle, Name, FMC, Record, Status, OrigRecord, Param1, Param2, Param3, Param4, Param5, Param6, Param7, Param8, Param9, Param10) #pragma precomp SRP_PreCompiler /*********************************************************************************************************************** This program is proprietary and is not to be used by or disclosed to others, nor is it to be copied without written permission from Infineon. Name : WO_LOG_Actions Description : Handles calculated columns and MFS calls for the current table. Notes : This function uses @ID, @RECORD, and @DICT to make sure {ColumnName} references work correctly. If called from outside of a calculated column these will need to be set and restored. Parameters : Action [in] -- Name of the action to be taken CalcColName [in] -- Name of the calculated column that needs to be processed. Normally this should only be populated when the CalcField action is being used. FSList [in] -- The list of MFSs and the BFS name for the current file or volume. This is an @SVM delimited array, with the current MFS name as the first value in the array, and the BFS name as the last value. Normally set by a calling MFS. Handle [in] -- The file handle of the file or media map being accessed. Note, this does contain the entire handle structure that the Basic+ Open statement would provide. Normally set by a calling MFS. Name [in] -- The name (key) of the record or file being accessed. Normally set by a calling MFS. FMC [in] -- Various functions. Normally set by a calling MFS. Record [in] -- The entire record (for record-oriented functions) or a newly-created handle (for "get handle" functions). Normally set by a calling MFS. Status [in/out] -- Indicator of the success or failure of an action. Normally set by the calling MFS but for some actions can be set by the action handler to indicate failure. OrigRecord [in] -- Original content of the record being processed by the current action. This is automatically being assigned by the WRITE_RECORD and DELETE_RECORD actions within BASE_MFS. Param1-10 [in/out] -- Additional request parameter holders ActionFlow [out] -- Used to control the action chain (see the ACTION_SETUP insert for more information.) Can also be used to return a special value, such as the results of the CalcField method. History : (Date, Initials, Notes) 07/28/10 dmb Original programmer. 10/13/10 dmb Fix logic to extract the file handle if file has an index 03/26/11 dmb Add logic to save and restore @FILE.ERROR ***********************************************************************************************************************/ $insert APP_INSERTS $insert FILE.SYSTEM.EQUATES $insert ACTION_SETUP $insert WO_MAT_EQUATES $insert WO_LOG_EQUATES $insert WO_STEP_EQUATES $insert RLIST_EQUATES $insert SCHED_DET_NG_EQUATES Equ Comma$ to ',' Declare function Error_Services, Database_Services, Environment_Services, Logging_Services, obj_WO_Mat, Datetime Declare function GaN_Services, obj_WO_Log Declare subroutine Error_Services, Database_Services, Environment_Services, Logging_Services, Obj_SAP Declare subroutine Logging_Services, Set_Status, Schedule_Services, Work_Order_Services, obj_Notes Declare subroutine Schedule_Services LogPath = Environment_Services('GetApplicationRootPath') : '\LogFiles\WO_LOG' LogDate = Oconv(Date(), 'D4/') LogTime = Oconv(Time(), 'MTS') LogFileName = LogDate[7, 4] : '-' : LogDate[1, 2] : '-' : LogDate[4, 2] : ' Work Order Log.csv' Headers = 'Logging DTM' : @FM : 'WO No' : @FM : 'Notes' objLog = Logging_Services('NewLog', LogPath, LogFileName, CRLF$, Comma$, Headers, '', False$, False$) LoggingDTM = LogDate : ' ' : LogTime ; // Logging DTM LogFileName = LogDate[7, 4] : '-' : LogDate[1, 2] : '-' : LogDate[4, 2] : ' Delete Attempt Log.csv' Headers = 'Logging DTM' : @FM : 'WO No' : @FM : 'Notes' objDeleteLog = Logging_Services('NewLog', LogPath, LogFileName, CRLF$, Comma$, Headers, '', False$, False$) LogFileName = LogDate[7, 4] : '-' : LogDate[1, 2] : '-' : LogDate[4, 2] : ' WO_HOLD Log.csv' Headers = 'Logging DTM' : @FM : 'WO No' : @FM : 'User' objHoldLog = Logging_Services('NewLog', LogPath, LogFileName, CRLF$, Comma$, Headers, '', False$, False$) If KeyID then GoSub Initialize_System_Variables Begin Case Case Action _EQC 'CalculateColumn' ; GoSub CalculateColumn Case Action _EQC 'READ_RECORD_PRE' ; GoSub READ_RECORD_PRE Case Action _EQC 'READ_RECORD' ; GoSub READ_RECORD Case Action _EQC 'READONLY_RECORD_PRE' ; GoSub READONLY_RECORD_PRE Case Action _EQC 'READONLY_RECORD' ; GoSub READONLY_RECORD Case Action _EQC 'WRITE_RECORD_PRE' ; GoSub WRITE_RECORD_PRE Case Action _EQC 'WRITE_RECORD' ; GoSub WRITE_RECORD Case Action _EQC 'DELETE_RECORD_PRE' ; GoSub DELETE_RECORD_PRE Case Action _EQC 'DELETE_RECORD' ; GoSub DELETE_RECORD Case Otherwise$ ; Status = 'Invalid Action' End Case If KeyID then GoSub Restore_System_Variables If Assigned(ActionFlow) else ActionFlow = ACTION_CONTINUE$ Return ActionFlow // ----- Calculated Columns -------------------------------------------------------------------------------------------- // // The typical structure of a calculated column will look like this: // // Declare function TableName_Actions // // A = {COL1} ; * Reference as many data columns in this way to ensure the dictionary dependency is generated. // // @ANS = TableName_Actions('CalcField', 'CalcColName') // // --------------------------------------------------------------------------------------------------------------------- CalculateColumn: // Make sure the ActionFlow return variable is cleared in case nothing is calculated. ActionFlow = '' Begin Case Case CalcColName EQ 'GAN_COST_TYPE' ; GoSub GAN_COST_TYPE Case CalcColName EQ 'SAP_YIELD_QTY' ; GoSub SAP_YIELD_QTY End Case return GAN_COST_TYPE: EpiStruct = {EPI_STRUCTURE} Begin Case Case ( (EpiStruct EQ 'HV') or (IndexC(EpiStruct, 'HEKLA', 1) GT 0) ) ActionFlow = 'High Voltage' Case EpiStruct EQ 'MV' ActionFlow = 'Mid Voltage' Case Otherwise$ ActionFlow = '' End Case return SAP_YIELD_QTY: If {REACTOR_TYPE} NE 'GAN' then ActionFlow = SUM({WO_MAT_SAP_YIELD}) end else WOStepRec = Database_Services('ReadDataRow', 'WO_STEP', {WO_STEP_KEY}) WOYield = 0 RDSKeys = WOStepRec For each RDSKey in RDSKeys using @VM RDSYieldInfo = GaN_Services('GetYieldInfo', RDSKey) GRWfrQty = RDSYieldInfo<1> ScrapQty = RDSYieldInfo<2> ProdTWQty = RDSYieldInfo<3> DummyQty = RDSYieldInfo<4> RDSYield = GRWfrQty - ScrapQty - ProdTWQty - DummyQty WOYield += RDSYield Next RDSKey end ActionFlow = WOYield return // ----- MFS calls ----------------------------------------------------------------------------------------------------- READ_RECORD_PRE: // In order to stop a record from being read in this action these lines of code must be used: // // OrigFileError = 100 : @FM : KeyID // Status = 0 // Record = '' // ActionFlow = ACTION_STOP$ return READ_RECORD: // In order to stop a record from being read in this action these lines of code must be used: // // OrigFileError = 100 : @FM : KeyID // Status = 0 // Record = '' return READONLY_RECORD_PRE: // In order to stop a record from being read in this action these lines of code must be used: // // OrigFileError = 100 : @FM : KeyID // Status = 0 // Record = '' // ActionFlow = ACTION_STOP$ return READONLY_RECORD: // In order to stop a record from being read in this action these lines of code must be used: // // OrigFileError = 100 : @FM : KeyID // Status = 0 // Record = '' return WRITE_RECORD_PRE: OrigQty = OrigRecord NewQty = Record OrigCassList = OrigRecord NewCassList = Record If ( (OrigQty NE NewQty) or (OrigCassList NE NewCassList) ) then // Update released, unreleased, and received quantities RelQty = obj_WO_Log('RelQty', Name:@RM:Record) Record = RelQty If RelQty GT NewQty then UnRelQty = 0 end else UnRelQty = NewQty - RelQty end Record = UnRelQty RXQty = obj_WO_Log('RxQty', Name:@RM:Record) Record = RXQty SaveRecord = Record end return WRITE_RECORD: Machine = Environment_Services('GetServer') If OrigRecord NE Record then // Log the user changing this flag. LogData = '' LogData<1> = LoggingDTM LogData<2> = Name LogData<3> = @User4 Message = @User4:' changed WO_HOLD flag for work order ':Name If Machine _NEC 'MESSA01EC' then Logging_Services('AppendLog', objHoldLog, LogData, @RM, @FM, '', 'dstieber@srpcs.com,6613649828@txt.att.net', Message) end else // EC Server can't send emails Logging_Services('AppendLog', objHoldLog, LogData, @RM, @FM) end end If ( (OrigRecord NE '') and (Record EQ '') and (Machine _NEC 'MESSA01EC') ) then Stack = RetStack() LogData = '' LogData<1> = LoggingDTM LogData<2> = Name LogData<3> = Stack Convert @FM to CRLF$ in Stack Message = 'Last char run erased on work order ':Name:'.':CRLF$:CRLF$:'Call Stack':CRLF$:Stack If Machine _NEC 'MESSA01EC' then Logging_Services('AppendLog', objLog, LogData, @RM, @FM, '', 'dstieber@srpcs.com,Francois.Rivard@infineon.com', Message) end else // EC Server can't send emails Logging_Services('AppendLog', objLog, LogData, @RM, @FM, '', '', '') end end OrigQty = OrigRecord NewQty = Record ModifyQty = NewQty - OrigQty WONo = Name SchedDetNGKey = '' Begin Case Case ModifyQty GT 0 LogData = '' LogData<1> = OConv(Datetime(), 'DT2/^H') LogData<2> = 'WO_LOG_ACTIONS' LogData<3> = 'Work order ':WONo:' quantity increased from ':OrigQty:' to ':NewQty:'.' Schedule_Services('LogActivity', '', LogData, False$) LogData<1> = OConv(Datetime(), 'DT2/^H') LogData<3> = 'Searching for a scheduled event to increase the quantity.' Schedule_Services('LogActivity', '', LogData, False$) // Search schedule for most recent event and increase that event quantity by the difference. Query = 'SELECT SCHED_DET_NG WITH WO_NO EQ ':WONo:' BY-DSND STOP_DTM' GoSub ClearCursors Set_Status(0) RList(Query, TARGET_ACTIVELIST$, '', '', False$) errCode = '' If Get_Status(errCode) then ErrorMsg = 'Error retrieving event list in WO_LOG_Actions. RList error code ':errCode:'.' LogData<1> = OConv(Datetime(), 'DT2/^H') LogData<3> = ErrorMsg Schedule_Services('LogActivity', '', LogData, False$) Error_Services('Add', ErrorMsg) end else EOF = False$ LogData<1> = OConv(Datetime(), 'DT2/^H') LogData<3> = 'Query successful. Number of keys found: ':@RecCount:'.' Schedule_Services('LogActivity', '', LogData, False$) ReadNext SchedDetNGKey else EOF = True$ If SchedDetNGKey NE '' then EventRec = Database_Services('ReadDataRow', 'SCHED_DET_NG', SchedDetNGKey) StopDTM = EventRec LogData<1> = OConv(Datetime(), 'DT2/^H') LogData<3> = 'Work order record ':WONo:' quantity increased from ':OrigQty:' to ':NewQty:'.' Schedule_Services('LogActivity', EventRec, LogData, False$) LogData<1> = OConv(Datetime(), 'DT2/^H') LogData<3> = 'Scheduled event ':SchedDetNGKey:' found.' Schedule_Services('LogActivity', EventRec, LogData, False$) // Only modify the event if it is still running or is scheduled in the future. If StopDTM GT Datetime() then LogData<1> = OConv(Datetime(), 'DT2/^H') LogData<3> = 'Event stop DTM ':OConv(StopDtm, 'DT2/^H'):' less than current DTM, so increasing event quantity.' Schedule_Services('LogActivity', EventRec, LogData, False$) ReactNo = EventRec WONo = EventRec StartDTM = EventRec Desc = EventRec EventQty = EventRec NewEventQty = EventQty + ModifyQty Schedule_Services('ModifySchedEvent', SchedDetNGKey, ReactNo, WONo, StartDTM, StopDTM, Desc, NewEventQty) // Adjust reactor events as needed. Schedule_Services('AdjustScheduleEvents', ReactNo) end else LogData<1> = OConv(Datetime(), 'DT2/^H') LogData<3> = 'Event stop DTM ':OConv(StopDtm, 'DT2/^H'):' greater than current DTM.' Schedule_Services('LogActivity', EventRec, LogData, False$) LogData<1> = OConv(Datetime(), 'DT2/^H') LogData<3> = 'Event quantity not increased.' Schedule_Services('LogActivity', EventRec, LogData, False$) end end end GoSub ClearCursors Case ModifyQty LT 0 LogData = '' LogData<1> = OConv(Datetime(), 'DT2/^H') LogData<2> = 'WO_LOG_ACTIONS' LogData<3> = 'Work order ':WONo:' quantity decreased from ':OrigQty:' to ':NewQty:'.' Schedule_Services('LogActivity', '', LogData, False$) LogData<1> = OConv(Datetime(), 'DT2/^H') LogData<3> = 'Searching for a scheduled event to decrease the quantity.' Schedule_Services('LogActivity', '', LogData, False$) // Search schedule for most recent events and decrease/delete those events as needed. Query = 'SELECT SCHED_DET_NG WITH WO_NO EQ ':WONo:' BY-DSND STOP_DTM' GoSub ClearCursors Set_Status(0) RList(Query, TARGET_ACTIVELIST$, '', '', False$) errCode = '' If Get_Status(errCode) then ErrorMsg = 'Error retrieving event list in WO_LOG_Actions. RList error code ':errCode:'.' LogData<1> = OConv(Datetime(), 'DT2/^H') LogData<3> = ErrorMsg Schedule_Services('LogActivity', '', LogData, False$) Error_Services('Add', ErrorMsg) end else LogData<1> = OConv(Datetime(), 'DT2/^H') LogData<3> = 'Query successful. Number of keys found: ':@RecCount:'.' Schedule_Services('LogActivity', '', LogData, False$) EOF = False$ Done = False$ UpdateReq = False$ Loop ReadNext SchedDetNGKey else EOF = True$ Until EOF EQ True$ If SchedDetNGKey NE '' then EventRec = Database_Services('ReadDataRow', 'SCHED_DET_NG', SchedDetNGKey) StopDTM = EventRec LogData<1> = OConv(Datetime(), 'DT2/^H') LogData<3> = 'Work order record ':WONo:' quantity decreased from ':OrigQty:' to ':NewQty:'.' Schedule_Services('LogActivity', EventRec, LogData, False$) LogData<1> = OConv(Datetime(), 'DT2/^H') LogData<3> = 'Scheduled event ':SchedDetNGKey:' found.' Schedule_Services('LogActivity', EventRec, LogData, False$) // Only modify the event if it is still running or is scheduled in the future. If StopDTM GT Datetime() then LogData<1> = OConv(Datetime(), 'DT2/^H') LogData<3> = 'Event stop DTM ':OConv(StopDtm, 'DT2/^H'):' less than current DTM, so decreasing event quantity.' Schedule_Services('LogActivity', EventRec, LogData, False$) UpdateReq = True$ ReactNo = EventRec WONo = EventRec StartDTM = EventRec Desc = EventRec EventQty = EventRec If EventQty GT Abs(ModifyQty) then // This event has enough wafers, so just reduce the quantity. LogData<1> = OConv(Datetime(), 'DT2/^H') LogData<3> = 'Event quantity ':EventQty:' greater than quantity reduction ':ModifyQty:', so decreasing event quantity.' Schedule_Services('LogActivity', EventRec, LogData, False$) Done = True$ NewEventQty = EventQty + ModifyQty Schedule_Services('ModifySchedEvent', SchedDetNGKey, ReactNo, WONo, StartDTM, StopDTM, Desc, NewEventQty) end else // This event has fewer wafers than are being removed. Delete this event and continue // onto the next event. LogData<1> = OConv(Datetime(), 'DT2/^H') LogData<3> = 'Event quantity ':EventQty:' less than quantity reduction ':ModifyQty:', so canceling event.' Schedule_Services('LogActivity', EventRec, LogData, False$) Schedule_Services('CancelScheduleEvent', SchedDetNGKey, True$) ModifyQty += EventQty end end else LogData<1> = OConv(Datetime(), 'DT2/^H') LogData<3> = 'Event stop DTM ':OConv(StopDtm, 'DT2/^H'):' greater than current DTM.' Schedule_Services('LogActivity', EventRec, LogData, False$) LogData<1> = OConv(Datetime(), 'DT2/^H') LogData<3> = 'Event quantity not decreased.' Schedule_Services('LogActivity', EventRec, LogData, False$) end end Until Done EQ True$ Repeat If UpdateReq then // Adjust reactor events as needed. Schedule_Services('AdjustScheduleEvents', ReactNo) end end GoSub ClearCursors Case Otherwise$ Null End Case return DELETE_RECORD_PRE: // Log which user and computer station attempted to delete the record LogData = '' LogData<1> = LoggingDTM LogData<2> = Name LogData<3> = @User4 Logging_Services('AppendLog', objDeleteLog, LogData, @RM, @FM) // Send an LSL message to FI admins to alert them Recipients = Xlate('SEC_GROUPS', 'OI_ADMIN', 'USER', 'X') SentFrom = 'SYSTEM' Subject = 'WO_LOG Delete Attempt' Message = 'An attempt to delete WO_LOG record ':Name:' was made by ':@User4:'.' AttachWindow = 'NDW_WO_LOG' AttachKey = Name SendToGroup = '' Parms = Recipients:@RM:SentFrom:@RM:Subject:@RM:Message:@RM:AttachWindow:@RM:AttachKey:@RM:SendToGroup obj_Notes('Create',Parms) // Stop the system from deleting the record ActionFlow = ACTION_STOP$ return DELETE_RECORD: return // ----- Internal Methods ---------------------------------------------------------------------------------------------- Initialize_System_Variables: // Save these for restoration later SaveDict = @DICT SaveID = @ID SaveRecord = @RECORD OrigFileError = @FILE.ERROR // Now make sure @DICT, ID, and @RECORD are populated CurrentDictName = '' If @DICT then DictHandle = @DICT<1, 2> Locate DictHandle in @TABLES(5) Using @FM Setting fPos then CurrentDictName = Field(@TABLES(0), @FM, fPos, 1) end end If CurrentDictName NE DictName then Open DictName to @DICT else Status = 'Unable to initialize @DICT' end @ID = KeyID If Record else // Record might not have been passed in. Read the record from the database table just to make sure. @FILE.ERROR = '' Open TableName to hTable then FullFSList = hTable[1, 'F' : @VM] BFS = FullFSList[-1, 'B' : @SVM] LastHandle = hTable[-1, 'B' : \0D\] FileHandle = \0D\ : LastHandle[1, @VM] Call @BFS(READO.RECORD, BFS, FileHandle, KeyID, FMC, Record, ReadOStatus) end end @RECORD = Record return Restore_System_Variables: Transfer SaveDict to @DICT Transfer SaveID to @ID Transfer SaveRecord to @RECORD @FILE.ERROR = OrigFileError return ClearCursors: For counter = 0 to 8 ClearSelect counter Next counter return