Function Scheduler_Actions_Modify_Events(CtrlEntId, Event, Param1, Param2, Param3, Param4, Param5, Param6, Param7, Param8, Param9, Param10, Param11, Param12, Param13, Param14, Param15) /*********************************************************************************************************************** This program is proprietary and is not to be used by or disclosed to others, nor is it to be copied without written permission from Infineon. Name : Scheduler_Actions_Modify_Events Description : This function acts as a commuter module for all events related to this window. Notes : Commuter Modules are automatically called from the Promoted_Events function which is called by the application-specific promoted event handler. This makes it possible to add QuickEvents that need to execute Basic+ logic without having use the Form Designer to make the association, although this is limited to the events which are currently promoted. If the form needs to call the commuter module directly then the QuickEvent parameters should be formatted like this: '@SELF','@EVENT',['@PARAM1','@PARAMx'] Parameters : CtrlEntId [in] -- The fully qualified name of the control calling the promoted event Event [in] -- The event being executed. See the Notes section regarding "PRE" events Param1-15 [in] -- Additional event parameter holders EventFlow [out] -- Set to 1 or 0 so the calling event knows whether or not to chain forward. See comments in EVENT_SETUP insert History : (Date, Initials, Notes) 02/19/21 djs Created initial commuter module. ***********************************************************************************************************************/ #pragma precomp SRP_PreCompiler #Window SCHEDULER_ACTIONS_MODIFY $insert APP_INSERTS $insert EVENT_SETUP $insert MSG_EQUATES $insert SCHED_DET_NG_EQUATES $insert WO_LOG_EQUATES $insert WO_SCHEDULE_NG_EQUATES $insert REACTOR_EQUATES Equ OI_DISABLED_GREY$ TO 239 + (239*256) + (239*65536) WorkOrderCtrls = 'OLE_DIV_WORK_ORDER_DETAILS,WO_NO_LABEL,WO_NO,EPI_PART_LABEL,EPI_PART,DESCRIPTION_LABEL,DESCRIPTION,CUSTOMER_NAME_LABEL,CUSTOMER_NAME,' WorkOrderCtrls := 'TOTAL_WAFERS_LABEL,TOTAL_WAFERS,TOTAL_REMAINING_LABEL,TOTAL_REMAINING,PERCENT_COMPLETE_LABEL,PERCENT_COMPLETE' DateRangeCtrls = 'SCHEDULE_START_DTM_LABEL,SCHEDULE_START_DTM,SCHEDULE_END_DTM_LABEL,SCHEDULE_END_DTM,DAYS_LABEL,DAYS' Declare function SRP_Array, Schedule_Services_Dev, Database_Services, Work_Order_Services, SRP_Math Declare function Epi_Part_Services, Datetime Declare subroutine obj_Appwindow, Center_Window, Schedule_Services_Dev, Form_Services, SRP_Show_Window Declare subroutine Form_Services SubclassInfo = Form_Services('FindSubclassControl') Subclass = SubclassInfo<1> // Update the arguments so that the OpenInsight OLE event will treate the ActiveX event as a native event handler. If Event EQ 'OLE' then Transfer Event to OIEvent Transfer Param1 to Event Transfer Param2 to Param1 Transfer Param3 to Param2 Transfer Param4 to Param3 Transfer Param5 to Param4 Transfer Param6 to Param5 Transfer Param7 to Param6 Transfer Param8 to Param7 end Type = Get_Property(CtrlEntId, 'TYPE') If Type EQ 'RADIOBUTTON' then Convert ' ' to '_' in CtrlEntID end GoToEvent Event for CtrlEntID Return EventFlow else EVENT_CONTINUE$ //////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// // Events //////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// Event WINDOW.CREATE(CreateParam) SchedDetNGKey = CreateParam<3> Set_Property(@Window, '@SCHEDULE_KEY_ID', SchedDetNGKey) GoSub PopulateControls Set_Property(@Window : '.DESCRIPTION', 'NEXT', @Window : '.NEW_QTY') SRP_Show_Window(@Window, '', 'C', 'C', 1, '', False$, False$) end event Event WINDOW.CLOSE(CancelFlag) end event Event SAVE_BUTTON.CLICK() GoSub UpdateWorkOrderDetails ResponseData = '' ReactorNo = Get_Property(@Window : '.REACTOR_NO', 'TEXT') WorkOrder = Get_Property(@Window : '.WO_NO', 'TEXT') StartDTM = Get_Property(@Window : '.SCHEDULE_START_DTM', 'INVALUE') EndDTM = Get_Property(@Window : '.SCHEDULE_END_DTM', 'INVALUE') Description = Get_Property(@Window : '.DESCRIPTION', 'INVALUE') NewQty = Get_Property(@Window : '.NEW_QTY', 'TEXT') If NewQty EQ '' then NewQty = Get_Property(@Window:'.SCHEDULE_WAFERS', 'INVALUE') ResponseData = ReactorNo : @FM : WorkOrder : @FM : StartDTM : @FM : EndDTM : @FM : Description : @FM : NewQty End_Dialog(@Window, ResponseData) end event Event CLOSE_BUTTON.CLICK() End_Dialog(@Window, '') end event Event OLE_SUBCLASS.OnOptionClick(CtrlId) Send_Event(CtrlId, 'OPTIONS') end event Event OLE_SUBCLASS.OnComboClick(CtrlId) Send_Event(CtrlId, 'LOSTFOCUS') end event Event NEW_QTY.CHAR(VirtCode, ScanCode, CtrlKey, ShiftKey, AltKey) Form_Services('CloseControlMessage', CtrlEntId) GoSub EnableSaveButton end event Event NEW_QTY.LOSTFOCUS(Flag, FocusID) ValidQty = False$ NewQty = Get_Property(CtrlEntID, 'TEXT') MinQty = Get_Property(@Window, '@MIN_QTY') MaxQty = Get_Property(@Window, '@MAX_QTY') Begin Case Case NewQty EQ '' Null Case NewQty LE 0 Set_Property(CtrlEntID, 'FOCUS', True$) Set_Property(CtrlEntID, 'SELECTION', 1 : @FM : 999) Message = 'New quantity must greater than zero.' Form_Services('DisplayControlMessage', Message, 'Invalid Quantity', CtrlEndID, 'VALIDATION', 'RGB(229,20,0)') Case NewQty LT MinQty Set_Property(CtrlEntID, 'FOCUS', True$) Set_Property(CtrlEntID, 'SELECTION', 1 : @FM : 999) Message = 'New quantity is below already processed quantity.' Form_Services('DisplayControlMessage', Message, 'Invalid Quantity', CtrlEndID, 'VALIDATION', 'RGB(229,20,0)') Case NewQty GT MaxQty Set_Property(CtrlEntID, 'FOCUS', True$) Set_Property(CtrlEntID, 'SELECTION', 1 : @FM : 999) Message = 'New quantity exceeds the available quantity.' Form_Services('DisplayControlMessage', Message, 'Invalid Quantity', CtrlEndID, 'VALIDATION', 'RGB(229,20,0)') Case Otherwise$ ValidQty = True$ End Case If ValidQty then GoSub UpdateWorkOrderDetails end event Event DESCRIPTION.CHAR(VirtCode, ScanCode, CtrlKey, ShiftKey, AltKey) GoSub EnableSaveButton end event //////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// // Internal GoSubs //////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// SelectAll: Set_Property(CtrlEntId, 'SELECTION', 1 : @FM : 999) return * UpdateScheduleDetails: * * ScheduleDetail = Schedule_Services_Dev('GetScheduleDetail', ScheduleKeyID) * Set_Property(@Window, '@ORIG_SCHEDULEDETAIL', ScheduleDetail) * Desc = ScheduleDetail * Set_Property(@Window : '.DESCRIPTION', 'TEXT', Desc) * Set_Property(@Window, '@ORIG_DESC', Desc) * * return UpdateCustomerName: WoNo = Get_Property(@Window : '.WO_NO', 'TEXT') If WoNo NE '' then WorkOrderDetail = Work_Order_Services('GetWorkOrderLogDetail', WONo) CustNo = WorkOrderDetail CompanyRow = Database_Services('ReadDataRow', 'COMPANY', CustNo) CustName = CompanyRow<42> end else CustName = '' end Set_Property(@Window : '.CUSTOMER_NAME', 'TEXT', CustName) return UpdateReactorDetails: ReactorNo = Get_Property(@Window : '.REACTOR_NO', 'TEXT') If Index(ReactorNo, '/', 1) then // EpiPro reactors formatted as such, "40/42". We must truncate the reactor number to the first reactor. ReactorNo = Field(ReactorNo, '/', 1, 1) Set_Property(@Window : '.REACTOR_NO', 'TEXT', ReactorNo) end ReactorDetails = Schedule_Services_Dev('GetReactorDetails', ReactorNo) ReactorType = ReactorDetails Begin Case Case ReactorType _EQC 'EPP' ; ReactorType = 'EpiPro' Case ReactorType _EQC 'GAN' ; ReactorType = 'GaN' End Case Set_Property(@Window : '.REACTOR_TYPE', 'TEXT', ReactorType) Set_Property(@Window : '.REACTOR_SIZE', 'TEXT', ReactorDetails) FutureEvents = Schedule_Services_Dev('GetScheduleEvents', Date() + 1, '', ReactorNo, '', False$) Set_Property(@Window, '@FUTURE_EVENTS', FutureEvents) return UpdateWorkOrderDetails: SchedDetNGKey = Get_Property(@Window, '@SCHEDULE_KEY_ID') If SchedDetNGKey NE '' then CurrDTM = Datetime() SchedDetNGRec = Database_Services('ReadDataRow', 'SCHED_DET_NG', SchedDetNGKey) WorkOrder = Get_Property(@Window : '.WO_NO', 'TEXT') ReactNo = Get_Property(@Window : '.REACTOR_NO', 'TEXT') WorkOrderDetail = Work_Order_Services('GetWorkOrderLogDetail', WorkOrder) EpiPart = WorkOrderDetail TotalWafers = WorkOrderDetail RemainingToProcess = Work_Order_Services('GetUnprocessedWafers', WorkOrder) RemainingToSchedule = Schedule_Services_Dev('GetUnscheduledWfrQty', WorkOrder) If TotalWafers GT 0 then Complete = ( (TotalWafers - RemainingToProcess) / TotalWafers) * 100 end else Complete = 0 end ReactorType = Get_Property(@Window : '.REACTOR_TYPE', 'TEXT') MinutesPerWaferAdjusted = Epi_Part_Services('GetAdjustedWafersPerDayScheduler', EpiPart, ReactorType) ScheduledWfrQty = Schedule_Services_Dev('GetScheduledWfrQty', WorkOrder) AvailableWfrQty = RemainingToSchedule CurrEventQty = Get_Property(@Window:'.SCHEDULE_WAFERS', 'TEXT') EventProcCass = SchedDetNGRec EventUnprocCass = SchedDetNGRec // Check for currently loaded cassettes LoadedCassettes = 0 EpiPro = (Xlate('WO_LOG', WorkOrder, 'REACT_TYPE', 'X') EQ 'EPP') For each CassNo in EventUnprocCass using @VM setting vPos If EpiPro then // Check if RDS in slot 25 is loaded into a reactor WMIKey = WorkOrder:'*1*':CassNo WMIRDSNos = Xlate('WM_IN', WMIKey, 'RDS_NO', 'X') LastSlotRDS = WMIRDSNos<0, 25> If LastSlotRDS NE '' then DateIn = Xlate('RDS', LastSlotRDS, 'DATE_IN', 'X') DateOut = Xlate('RDS', LastSlotRDS, 'DATE_OUT', 'X') If ( (DateIn NE '') and (DateOut EQ '') ) then // Cassette is loaded into a reactor, so this cassette cannot be removed from the event. LoadedCassettes += 1 end end end else // Check if RDS is loaded into a reactor WOMatKey = WorkOrder:'*':CassNo RDSNo = Xlate('WO_MAT', WOMatKey, 'RDS_NO', 'X') If RDSNo NE '' then DateIn = Xlate('RDS', RDSNo, 'DATE_IN', 'X') DateOut = Xlate('RDS', RDSNo, 'DATE_OUT', 'X') If ( (DateIn NE '') and (DateOut EQ '') ) then // Cassette is loaded into a reactor, so this cassette cannot be removed from the event. LoadedCassettes += 1 end end end Next CassNo ProcessedWfrQty = (DCount(EventProcCass, @VM) * 25) UnprocessedWfrQty = Schedule_Services_Dev('GetEventRemainingWfrs', SchedDetNGKey) NewEventQty = Get_Property(@Window:'.NEW_QTY', 'TEXT') StartDTM = SchedDetNGRec If ( (NewEventQty NE CurrEventQty) and (NewEventQty NE '') ) then DurationEstimate = Schedule_Services_Dev('GetEventDuration', WorkOrder, (NewEventQty - ProcessedWfrQty)) EndDTM = CurrDTM + DurationEstimate end else EndDTM = SchedDetNGRec end TotalRunTime = EndDTM - StartDTM CurrEventQty = SchedDetNGRec NewEventMin = CurrEventQty - UnprocessedWfrQty Set_Property(@Window, '@MIN_QTY', NewEventMin) NewEventMax = RemainingToSchedule + CurrEventQty Set_Property(@Window, '@MAX_QTY', NewEventMax) NewQtyLabel = 'New Qty (':NewEventMin:' - ':NewEventMax:'):' If MinutesPerWaferAdjusted EQ '' then Msg(@Window, 'Warning: ' : EpiPart : ' appears to be missing minutes per wafer values for ' : ReactorType) end end If (SchedDetNGKey NE '') then Set_Property(@Window : '.EPI_PART', 'TEXT', EpiPart) Set_Property(@Window : '.TOTAL_WAFERS', 'TEXT', TotalWafers) Set_Property(@Window : '.TOTAL_REMAINING', 'TEXT', RemainingToProcess) Set_Property(@Window : '.PERCENT_COMPLETE', 'TEXT', Oconv(Complete, 'MD0[ %]S')) Set_Property(@Window : '.SCHEDULE_END_DTM', 'INVALUE', EndDTM) RunTimeRounded = SRP_Math('ROUND', TotalRunTime, 1) Set_Property(@Window : '.DAYS', 'DEFPROP', RunTimeRounded) Set_Property(@Window : '.AVAILABLE_QTY', 'TEXT', AvailableWfrQty) Set_Property(@Window : '.OPTIONS_NEW_QTY', 'TEXT', NewQtyLabel) end else Error_Services('DisplayError') Set_Property(@Window : '.EPI_PART', 'TEXT', '') Set_Property(@Window : '.TOTAL_WAFERS', 'TEXT', '') Set_Property(@Window : '.TOTAL_REMAINING', 'TEXT', '') Set_Property(@Window : '.SCHEDULE_WAFERS', 'TEXT', '') Set_Property(@Window : '.PERCENT_COMPLETE', 'TEXT', '') Set_Property(@Window : '.SCHEDULE_END_DTM', 'INVALUE', '') Set_Property(@Window : '.DAYS', 'DEFPROP', '') end GoSub EnableSaveButton return PopulateControls: Set_Property(@Window, 'TEXT', 'Scheduler Actions - Modify Work Order Event') Set_Property(@Window : '.REACTOR_NO', 'NEXT', @Window : '.SCHEDULE_START_DTM') Set_Property(@Window : '.DESCRIPTION', 'NEXT', @Window : '.REACTOR_NO') SchedDetNGKey = Get_Property(@Window, '@SCHEDULE_KEY_ID') SchedDetRec = Schedule_Services_Dev('GetScheduleDetail', SchedDetNGKey) WONo = SchedDetRec ReactorNo = SchedDetRec StartDTM = SchedDetRec StopDTM = SchedDetRec EventWfrs = SchedDetRec Desc = SchedDetRec Set_Property(@Window : '.WO_NO', 'TEXT', WONo) Set_Property(@Window : '.REACTOR_NO', 'TEXT', ReactorNo) Set_Property(@Window : '.SCHEDULE_START_DTM', 'INVALUE', StartDTM) Set_Property(@Window : '.SCHEDULE_END_DTM', 'INVALUE', StopDTM) Set_Property(@Window : '.SCHEDULE_WAFERS', 'INVALUE', EventWfrs) Set_Property(@Window : '.DESCRIPTION', 'INVALUE', Desc) * GoSub UpdateScheduleDetails GoSub UpdateReactorDetails GoSub UpdateCustomerName GoSub UpdateWorkOrderDetails Set_Property(@Window : '.REACTOR_NO', 'FOCUS', True$) return EnableSaveButton: OrigDesc = Get_Property(@Window, '@ORIG_DESC') NewDesc = Get_Property(@Window : '.DESCRIPTION', 'TEXT') CurrQty = Get_Property(@Window : '.SCHEDULE_WAFERS', 'TEXT') NewQty = Get_Property(@Window : '.NEW_QTY', 'TEXT') MinQty = Get_Property(@Window, '@MIN_QTY', 'TEXT') MaxQty = Get_Property(@Window, '@MAX_QTY', 'TEXT') DescChange = (NewDesc NE OrigDesc) QtyChange = ( (NewQty NE '') and (NewQty NE CurrQty) and (NewQty GT 0) and (NewQty LE MaxQty) and (NewQty GE MinQty) ) ButtonEnabled = (DescChange or QtyChange) Set_Property(@Window : '.SAVE_BUTTON', 'ENABLED', ButtonEnabled) return