Compile function NDW_TEST_RUN_EVENTS(CtrlEntId, Event, @PARAMS) /*********************************************************************************************************************** This program is proprietary and is not to be used by or disclosed to others, nor is it to be copied without written permission from Infineon. Name : NDW_Test_Run_Events Description : This function acts as a commuter module for all events related to this window. Notes : Commuter Modules are automatically called from the Promoted_Events function which is called by the application-specific promoted event handler. This makes it possible to add QuickEvents that need to execute Basic+ logic without having use the Form Designer to make the association, although this is limited to the events which are currently promoted. If the form needs to call the commuter module directly then the QuickEvent parameters should be formatted like this: '@SELF','@EVENT',['@PARAM1','@PARAMx'] Parameters : CtrlEntId [in] -- The fully qualified name of the control calling the promoted event Event [in] -- The event being executed. See the Notes section regarding "PRE" events Param1-15 [in] -- Additional event parameter holders EventFlow [out] -- Set to 1 or 0 so the calling event knows whether or not to chain forward. See comments in EVENT_SETUP insert History : (Date, Initials, Notes) 06/05/24 djs Updated commuter module to keep form open after clicking submit button. (backlog req. 849) ***********************************************************************************************************************/ #pragma precomp SRP_PreCompiler #window NDW_TEST_RUN Declare function Get_Property, Test_Run_Services, Database_Services, Reactor_Services, Tool_Services, Test_Run_Services Declare subroutine Set_Property, Test_Run_Services, PlaceDialog $Insert EVENT_SETUP $Insert RDS_EQUATES $Insert TEST_RUN_TYPE_EQUATES $Insert APP_INSERTS $Insert LOGICAL TWTableOLECtrl = @Window : '.OLE_TW_USAGE_TABLE' // Update the arguments so that the OpenInsight OLE event will treate the ActiveX event as a native event handler. If Event EQ 'OLE' then Transfer Event to OIEvent Transfer Param1 to Event Transfer Param2 to Param1 Transfer Param3 to Param2 Transfer Param4 to Param3 Transfer Param5 to Param4 Transfer Param6 to Param5 Transfer Param7 to Param6 Transfer Param8 to Param7 end GoToEvent Event for CtrlEntId else // Event not implemented end Return EventFlow or 1 //----------------------------------------------------------------------------- // EVENT HANDLERS //----------------------------------------------------------------------------- Event WINDOW.CREATE(CreateParam) PlaceDialog(-2, -2) Set_Property(@Window, 'VISIBLE', 1) GoSub SetupOLEControls GoSub FillFormMasterData EventFlow = 1 PlaceDialog(-2, -2) End Event Event EDL_RDS.CHANGED(NewData) RDSNo = NewData If Len(RDSNo) GE 6 then If RowExists('RDS', RDSNo) then RDSRec = Database_Services('ReadDataRow', 'RDS', RDSNo) PSN = RDSRec ReactorNo = RDSRec If PSN NE '' then Set_Property(@Window : '.EDL_PSN', 'TEXT', PSN) Set_Property(@Window : '.EDL_PSN', 'ENABLED', -1) end If ReactorNo NE '' then Set_Property(@Window : '.CMB_EQUIP_TYPE', 'VALUE', 'Reactor') Set_Property(@Window : '.CMB_EQUIP_TYPE', 'ENABLED', -1) Set_Property(@Window : '.CMB_EQUIPMENT_ID', 'TEXT', ReactorNo) Set_Property(@Window : '.CMB_EQUIPMENT_ID', 'ENABLED', -1) end end end else Set_Property(@Window : '.EDL_PSN', 'TEXT', '') Set_Property(@Window : '.EDL_PSN', 'ENABLED', True$) Set_Property(@Window : '.CMB_EQUIPMENT_ID', 'TEXT', '') Set_Property(@Window : '.CMB_EQUIPMENT_ID', 'ENABLED', True$) Set_Property(@Window : '.CMB_EQUIP_TYPE', 'ENABLED', True$) end end event Event CMB_EQUIP_TYPE.CHANGED(Selection) Begin Case Case Selection EQ 'Reactor' EqpOpts = Get_Property(@Window , '@REACTOR_OPTS', 'TEXT') Case Selection EQ 'Non-Reactor' EqpOpts = Get_Property(@Window , '@NON_REACTOR_OPTS', 'TEXT') Case 0 EqpOpts = Get_Property(@Window , '@REACTOR_OPTS', 'TEXT') End Case Set_Property(@Window : '.CMB_EQUIPMENT_ID', 'LIST', EqpOpts) end event Event PUB_ADD_ROW.CLICK() Index = Send_Message(TWTableOLECtrl, "OLE.InsertRecords", -1, 1) end event Event PUB_DELETE_ROW.CLICK() //Get currently selected Row SelectedCell = Get_Property(TWTableOLECtrl, 'OLE.SelPos') If SelectedCell then SelectedRow = SelectedCell<2> rv = Send_Message(TWTableOLECtrl, "OLE.DeleteRecords", SelectedRow, 1) end end event Event PUB_SUBMIT.CLICK() NotReadyReason = '' //Gather all field information ReasonForTest = Get_Property(@Window : '.CMB_TEST_TYPE', 'TEXT') RelatedRDS = Get_Property(@Window : '.EDL_RDS', 'TEXT') RelatedPSN = Get_Property(@Window : '.EDL_PSN', 'TEXT') EquipmentType = Get_Property(@Window : '.CMB_EQUIP_TYPE', 'TEXT') EquipmentID = Get_Property(@Window : '.CMB_EQUIPMENT_ID', 'TEXT') //Translate selection to IDs. Get Run Type ID SelRunTypeID = '';*Test Run Obj variable RunTypeOpts = Get_Property(@Window, '@RUN_TYPE_OPTS') Locate ReasonForTest in RunTypeOpts<2> using @VM setting rPos then SelRunTypeID = RunTypeOpts<1, rPos> end else NotReadyReason := 'Must select a valid run type reason.' : CRLF$ end //Translate Equipment Type. R for Reactor, T for non-reactor SelEquipType = '';*Test Run Obj variable Begin Case Case EquipmentType EQ 'Reactor' SelEquipType = 'R' Case EquipmentType EQ 'Non-Reactor' SelEquipType = 'T' End Case //Get Test wafer usage data from table TWProdOpts = Get_Property(@Window, '@TW_PROD_OPTS') TWUsageData = Get_Property(TWTableOLECtrl, 'OLE.RecordData[All]') ProdUsages = '' for each TWRow in TWUsageData using @FM ProdID = '' Quantity = TWRow<1,2> ProdName = TWRow<1,1> If Quantity NE '' AND ProdName NE '' then if Num(Quantity) AND Quantity GT 0 then Locate ProdName in TWProdOpts<2> setting tPos then ProdID = TWProdOpts<1, tPos> ProdUsages<-1> = ProdID : @VM : Quantity end else NotReadyReason := 'Invalid Product ID ' : ProdName : ' selected.' : CRLF$ end end else NotReadyReason := 'Quantity for Product ID ' : ProdName : ' was not a number or was a negative number.' : CRLF$ end end else Begin Case Case Quantity NE '' NotReadyReason := 'Prod. not selected..' : CRLF$ Case ProdName NE '' NotReadyReason := 'Qty for ' : ProdName : ' is blank' : CRLF$ End Case end Next TWRow If NotReadyReason EQ '' then NewTWRunKey = Test_Run_Services('CreateTestRunRecord', SelRunTypeID, SelEquipType, EquipmentID, RelatedPSN, RelatedRDS, @User4) If Error_Services('NoError') AND RowExists('TEST_RUN', NewTWRunKey) then for each Prod in ProdUsages using @FM setting pPos for i = 1 to Prod<1,2> TWPartID = Prod<1,1> TRWaferKey = Test_Run_Services('CreateTestRunWaferRecord', NewTWRunKey, TWPartID, @USER4) If RowExists('TEST_RUN_WAFER', TRWaferKey) then //Do Nothing for now. end else msg(@Window, 'Error writing Test Run data! Please try again or contact FI for support.') end Next i Next Prod If Error_Services('NoError') then Msg(@Window, 'Test Run Created Successfully!') GoSub ClearFormData end end else msg(@Window, 'Error writing Test Run data! Please try again or contact FI for support.') end end else Msg(@Window, NotReadyReason) end end event Event PUB_CANCEL.CLICK() Post_Event(@Window, 'CLOSE') end event //////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// // Internal GoSubs //////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// ClearFormData: Set_Property(@Window : '.CMB_TEST_TYPE', 'TEXT', '') Set_Property(@Window : '.EDL_RDS', 'TEXT', '') Set_Property(@Window : '.EDL_PSN', 'TEXT', '') Set_Property(@Window : '.CMB_EQUIP_TYPE', 'TEXT', 'Reactor') Set_Property(@Window : '.CMB_EQUIPMENT_ID', 'TEXT', '') Set_Property(@Window : '.OLE_TW_USAGE_TABLE', 'OLE.RecordData[All]', '') Set_Property(@Window : '.OLE_TW_USAGE_TABLE', 'OLE.Dimension', 2:@FM:1) return FillFormMasterData: //Get Test run type options. Populate to CMB_TEST_TYPE TestRunTypeList = Test_Run_Services('GetAllTestRunTypes') Set_Property(@Window, '@RUN_TYPE_OPTS', TestRunTypeList) TestRunTypeOpts = '' for each TestRunID in TestRunTypeList<1> using @VM setting tPos TestRunName = TestRunTypeList<2, tPos> TestRunTypeOpts<-1> = TestRunName Next TestRunID Set_Property(@Window : '.CMB_TEST_TYPE', 'LIST', TestRunTypeOpts) //Get Tool and Reactor Identifiers and buffer them in user defined window properties @REACTOR_OPTS and @NON_REACTOR_OPTS //Reactors ReactorOpts = Reactor_Services('GetReactorNumbers') Set_Property(@Window : '.EDT_REACTORS', 'TEXT', ReactorOpts) Set_Property(@Window, '@REACTOR_OPTS', ReactorOpts) //Non Reactors NonReactorOpts = Tool_Services('GetAllTools') swap @VM with @FM in NonReactorOpts Set_Property(@Window : '.EDT_NON_REACTORS', 'TEXT', NonReactorOpts) Set_Property(@Window, '@NON_REACTOR_OPTS', NonReactorOpts) //Then set the inital combo list to be filled with reactors because that is the default. Set_Property(@Window : '.CMB_EQUIPMENT_ID', 'LIST', ReactorOpts) //Get TW Products and store them in user defined window property @TW_PROD_OPTS Prods = Test_Run_Services('GetAllTWProdKeys', 1) Set_Property(@Window, '@TW_PROD_OPTS', Prods) //Add Product options to the OLE_TW_USAGE_TABLE ProdOpts = Prods<2> swap @VM with @STM in ProdOpts TWProdOpts<1> = 'COB' Set_Property(TWTableOLECtrl, "OLE.CellType[1; ALL]", ProdOpts) TypeData = '' TypeData<1> = "Combo" TypeData<2, 1> = 'Prod Name' TypeData<2, 2> = "L" TypeData<2, 3> = ProdOpts TypeData<2, 4> = 1 ;// column 2 contains the values we care about TypeData<2, 5> = 1 ;// auto fill on TypeData<2, 6> = 0 ;// case sensitive off TypeData<2, 7> = 10 ;// 10 visible rows max TypeData<2, 8> = 0 ;// Don't fire the OnOptionClick TypeData<2, 9> = 1 ;// Reduce the list to partial matches TypeData<2, 10> = 0 ;// Only show the drop down when the user types TypeData<2, 11> = 0 ;// Do not use LIST Format TypeData<2, 12> = 1 ;// Autofill on first names TypeData<2, 13> = 1 ;// Hide dropdown when user clears cell TypeData<2, 14> = 0 ;// Let navigation keys show the drop down TypeData<2, 15> = 0 ;// Show the drop down regardless of the cell's contents TypeData<2, 16> = 0 ;// Show the drop down during autofill TypeData<2, 17> = 1 ;// Remove selection when user backspaces/deletes TypeData<2, 18> = 0 ;// Show Popup while in read only mode TypeData<2, 19> = 1 ;// Show Popup When Navigating TypeData<2, 20> = 1 ;// Always Tab Out on Enter TypeData<2, 21> = -1 ;// Always show the dropdown above when close to the screen bottom Set_Property(TWTableOLECtrl, "OLE.CellType[1; All]", TypeData) return SetupOLEControls: Set_Property(TWTableOLECtrl, "OLE.AllowInserts", 0) Set_Property(TWTableOLECtrl, "OLE.BlankRowManagement", 1:@FM:0) Set_Property(TWTableOLECtrl, "OLE.Dimension", 2);*Define number of columns //Set Column width of tw prod column ColSizeArray = '' ColSizeArray<1> = 150 Set_Property(TWTableOLECtrl, "OLE.DataColumn[All]", ColSizeArray) //Set Column Header Titles HeaderTitles = 'Test Wafer Prod':@VM:'Quantity'; *Define the column header titles Set_Property(TWTableOLECtrl, "OLE.TitleList", HeaderTitles); *Set the column titles //Sets column header to be invisible Set_Property(TWTableOLECtrl, "OLE.HeaderColumn[1]", '':@FM:False$) //Set first field as a dropdown TWProdOpts = Get_Property(TWTableOLECtrl, "OLE.CellType[1; ALL]") //Cell Default coloring CellColors = "" CellColors<4> = 'LightCyan' Set_Property(TWTableOLECtrl, "OLE.CellSelColors[All; All]", CellColors) //Selection Properties SelArray = '' SelArray<8> = True$ Set_Property(TWTableOLECtrl, "OLE.SelectionStyle", SelArray) //Maintains SelPos on lostfocus Set_Property(TWTableOLECtrl, 'OLE.Redraw', False$) Set_Property(TWTableOLECtrl, "OLE.ResetSelPos", False$) //Qualify OLE Events Qualifier = '' Qualifier<1> = 1 Qualifier<4> = 0 ; * process synchronously (i.e. immediately) Send_Message(TWTableOLECtrl, 'QUALIFY_EVENT', 'OLE.OnLostFocus', Qualifier) return