COMPILE FUNCTION Comm_WO_Prod_GaN(EntID,Event,Parm1,Parm2,Parm3,Parm4,Parm5) #pragma precomp SRP_PreCompiler /* Commuter module for WO_Prod_GaN, Read Only WO Step window for production use (Work Order Step) Work Order step table 05/13/2016 - John C. Henry, J.C. Henry & Co., Inc. 11/23/2020 - djs - Added PUB_ADD_OUT_CASS.CLICK event */ DECLARE SUBROUTINE Set_Property, Set_Status, ErrMsg, Set_Property, obj_AppWindow, obj_Notes, obj_WM_Out, obj_Post_Log DECLARE SUBROUTINE obj_SAP, obj_Run_Stage, Print_Control_Plan, Send_Info, obj_Tables, End_Window, Start_Window DECLARE SUBROUTINE Btree.Extract, Send_Event, Security_Err_Msg, Forward_Event, Post_Event, Error_Services DECLARE SUBROUTINE Work_Order_Services DECLARE FUNCTION Get_Property, Get_Status, Popup, Send_Message, Msg, Security_Check, Dialog_Box, RowExists, obj_Tables DECLARE FUNCTION Dialog_Box, obj_WO_Log, obj_RDS, obj_WM_Out,obj_React_Run, Set_Property, obj_Prod_Spec, MemberOf DECLARE FUNCTION GaN_Services, Work_Order_Services, Error_Services $INSERT POPUP_EQUATES $INSERT LOGICAL $INSERT MSG_EQUATES $INSERT APPCOLORS $INSERT WO_LOG_EQUATES $INSERT WO_STEP_EQU $INSERT WO_MAT_EQUATES $INSERT WM_OUT_EQUATES $INSERT ORDER_EQU $INSERT ORDER_DET_EQU $INSERT QUOTE_SPEC_EQU $INSERT PROD_SPEC_EQUATES $INSERT PRS_STAGE_EQUATES $INSERT EPI_PART_EQUATES $INSERT REACT_RUN_EQUATES $INSERT LSL_USERS_EQU $INSERT SECURITY_RIGHTS_EQU $INSERT QUOTE_SIGS_EQU $INSERT RTI_STYLE_EQUATES EQU CRLF$ TO \0D0A\ EQU COL$ADD_DESC TO 1 EQU COL$ADD_AMT TO 2 EQU COL$RUNS_RUN_NO TO 1 EQU COL$RUNS_CHAR_STATUS TO 2 EQU COL$RUNS_RDS_NO TO 3 EQU COL$RUNS_GAN_RUN TO 4 EQU COL$WM_IN_CASS_NO TO 1 EQU COL$WM_IN_QTY TO 2 EQU COL$WM_IN_REJ TO 3 EQU COL$WM_IN_REMAINING TO 4 ErrCode = '' ErrorMsg = '' ErrTitle = 'Error in Comm_WO_Prod_GaN' Result = '' BEGIN CASE CASE EntID = @WINDOW BEGIN CASE CASE Event = 'CLEAR' ; GOSUB Clear CASE Event = 'CREATE' ; GOSUB Create CASE Event = 'CLOSE' ; GOSUB Close CASE Event = 'WRITE' ; GOSUB Write CASE Event = 'READ' ; GOSUB Read CASE Event = 'CLOSE' ; GOSUB Close CASE Event = 'GOTFOCUS' ; GOSUB GotFocus CASE Event[1,3] = 'QBF' ; GOSUB Refresh END CASE CASE EntID = @WINDOW:'.WO_NO' AND Event = 'LOSTFOCUS' ; GOSUB WONoLF CASE EntID = @WINDOW:'.PROC_STEP_NO' AND Event = 'GOTFOCUS' ; GOSUB StepGF CASE EntID = @WINDOW:'.CONTROL_PLAN' AND Event = 'CLICK' ; GOSUB ControlPlan CASE EntID = @WINDOW:'.VIEW_PSN_BUTTON' AND Event = 'CLICK' ; GOSUB ViewProdSpec CASE EntID = @WINDOW:'.NEW_RDS' AND Event = 'CLICK' ; GOSUB CreateRDS CASE EntID = @WINDOW:'.LU_WO_NO' AND Event = 'CLICK' ; GOSUB LUWONo CASE EntID = @WINDOW:'.PUB_VIEW_WO' AND Event = 'CLICK' ; GOSUB ViewWorkOrder CASE EntID = @WINDOW:'.RUNS' AND Event = 'DBLCLK' ; GOSUB RdsDC CASE EntID = @WINDOW:'.OUT_WFRS' AND Event = 'DBLCLK' ; GOSUB OutCassDC CASE EntID = @WINDOW:'.WO_MAT_KEYS' AND Event = 'DBLCLK' ; GOSUB InCassDC CASE EntID = @WINDOW:'.PUB_ADD_OUT_CASS' AND Event = 'CLICK' ; GOSUB AddOutboundCass CASE 1 ErrorMsg = 'Unknown Parameters ':EntID:' - ':Event:' passed to commuter' ErrMsg(ErrorMsg) END CASE IF ErrorMsg NE '' THEN ErrMsg(ErrTitle:@SVM:ErrorMsg) END RETURN Result * * * * * * * Create: * * * * * * * obj_Appwindow('Create',@WINDOW) QuoteSigs = XLATE( 'CONFIG', 'QUOTE_SIGS','', 'X' ) IF @USER4 = QuoteSigs OR MemberOf(@USER4, 'OI_SUPERUSER') THEN Set_Property(@WINDOW:'.REM_CASSETTES','VISIBLE',1) Set_Property(@WINDOW:'.REM_WM_OUT','VISIBLE',1) END ELSE Set_Property(@WINDOW:'.REM_CASSETTES','VISIBLE',0) Set_Property(@WINDOW:'.REM_WM_OUT','VISIBLE',0) END GOSUB Refresh RETURN * * * * * * * Read: * * * * * * * WONo = Get_Property(@WINDOW:'.WO_NO','TEXT') IF RowExists('WO_LOG',WONo) ELSE ErrMsg('Incorrect Work Order Number entered.') Send_Event(@WINDOW,'CLEAR') RETURN END GOSUB Refresh RETURN * * * * * * * Write: * * * * * * * RETURN * * * * * * * Clear: * * * * * * * Send_Event(@WINDOW,'PAGE',1) GOTO Refresh RETURN * * * * * * * Delete: * * * * * * * RETURN * * * * * * * Page: * * * * * * * obj_Appwindow('Page') GOSUB Refresh RETURN * * * * * * * Close: * * * * * * * obj_Appwindow('DetailReturn') RETURN * * * * * * * GotFocus: * * * * * * * RETURN * * * * * * * WONoLF: * * * * * * * DataValue = Get_Property(@WINDOW:'.WO_NO','TEXT') If DataValue = '' Then RETURN IF INDEX(DataValue,'.',1) THEN * Try a BTREE lookup on PROD_ORD_NO OPEN 'DICT.WO_LOG' TO DictVar ELSE ErrMsg('Unable to open "DICT.WO_LOG" for index lookup in COMM_SHIPMENT routine.') RETURN END SearchString = 'PROD_ORD_NO':@VM:DataValue:@FM WONos = '' Flag = '' Btree.Extract(SearchString, 'WO_LOG', DictVar, WONos, '', Flag) IF Get_Status(errCode) THEN ErrMsg(errCode) RETURN END IF WONos = '' THEN ErrMsg('Value Entered "':DataValue:'" is not found.') Result = 0 RETURN END IF INDEX(WONos,@VM,1) THEN * This is an error ErrMsg('Multiple Work Orders ':QUOTE(DataValue):' for Prod Order entered.') Result = 0 RETURN END ELSE Set_Property(@WINDOW:'.WO_NO','DEFPROP',WONos) END Result = 1 END ELSE IF RowExists('WO_LOG', DataValue) THEN Result = 1 END ELSE Message = QUOTE(DataValue):' is not a valid WO No' ErrMsg(Message) Set_Property(@WINDOW:'.WO_NO','DEFPROP','') Result = 0 END END RETURN * * * * * * * Refresh: * * * * * * * PSStatus = Get_Property(@WINDOW:'.PS_STATUS','TEXT') IF PSStatus = 'Active' THEN Set_Property(@WINDOW:'.PS_STATUS','BACKCOLOR',GREEN$) END ELSE Set_Property(@WINDOW:'.PS_STATUS','BACKCOLOR',RED$) END * WM_IN background colors // Doesn't apply to this form * CtrlName = @WINDOW:'.WM_IN' * WMInArray = Get_Property(CtrlName,'INVALUE') * * WMInStatuses = WMInArray * FOR I = 1 TO COUNT(WMInStatuses,@VM) + (WMInStatuses NE '') * WMInStatus = WMInStatuses<1,I> * * BEGIN CASE * CASE WMInStatus = 'Ready to Build' ; LineColor = RCV_BLUE$ * CASE WMInStatus = 'Building' ; LineColor = PRE_BLUE$ * CASE WMInStatus = 'Cond Post Clean' ; LineColor = INP_BLUE$ * CASE WMInStatus = 'Ready to Post Clean' ; LineColor = INP_BLUE$ * CASE WMInStatus = 'Ready for QA' ; LineColor = POS_BLUE$ * CASE WMInStatus = 'Ready to Use' ; LineColor = GREEN$ * CASE WMInStatus = 'Ready to Ship' ; LineColor = GREEN$ * CASE WMInStatus = 'Shipped' ; LineColor = LTGREY$ * CASE WMInStatus = 'Empty' ; LineColor = LTGREY$ * CASE WMInStatus = 'On Hold' ; LineColor = RED$ * CASE WMInStatus = 'Open NCR' ; LineColor = RED$ * CASE WMInStatus = 'Cassette Rejected' ; LineColor = ORANGE$ * CASE 1 ; LineColor = WHITE$ * END CASE * * stat = Send_Message(CtrlName,'COLOR_BY_POS',0,I,LineColor) * NEXT I * All cassette detail background colors CtrlName = @WINDOW:'.RUNS' CassArray = Get_Property(CtrlName,'ARRAY') CharStatuses = CassArray NumRows = DCount(CharStatuses, @VM) FOR RowIndex = 1 TO NumRows CharStatus = CharStatuses<0, RowIndex> BEGIN CASE CASE CharStatus EQ 'Sched-Done' ; LineColor = LTBLUE$ CASE CharStatus EQ 'Done' ; LineColor = GREEN$ CASE CharStatus EQ 'Sched' ; LineColor = YELLOW$ CASE CharStatus EQ 'Skipped' ; LineColor = RED$ CASE Otherwise$ ; LineColor = WHITE$ END CASE stat = Send_Message(CtrlName, 'COLOR_BY_POS', COL$RUNS_CHAR_STATUS, RowIndex, LineColor) NEXT I * WM_OUT background colors * CtrlName = @WINDOW:'.WM_OUT' * WMOutArray = Get_Property(CtrlName,'INVALUE') * * WMOutStatuses = WMOutArray * FOR I = 1 TO COUNT(WMOutStatuses,@VM) + (WMOutStatuses NE '') * WMOutStatus = WMOutStatuses<1,I> * * BEGIN CASE * CASE WMOutStatus = 'Ready to Build' ; LineColor = RCV_BLUE$ * CASE WMOutStatus = 'Building' ; LineColor = PRE_BLUE$ * CASE WMOutStatus = 'PostEpi Clean' ; LineColor = INP_BLUE$ * CASE WMOutStatus = 'PostEpi Surfscan' ; LineColor = INP_BLUE$ * CASE WMOutStatus = 'PostEpi Inspection' ; LineColor = POS_BLUE$ * CASE WMOutStatus = 'Ready for QA' ; LineColor = POS_BLUE$ * CASE WMOutStatus = 'Ready to Use' ; LineColor = MU_GREEN$ * CASE WMOutStatus = 'QA Complete' ; LineColor = YELLOW$ * CASE WMOutStatus = 'Ready to Ship' ; LineColor = GREEN$ * CASE WMOutStatus = 'Shipped' ; LineColor = LTGREY$ * CASE WMOutStatus = 'Empty' ; LineColor = LTGREY$ * CASE WMOutStatus = 'Void' ; LineColor = GREY$ * CASE WMOutStatus = 'On Hold' ; LineColor = RED$ * CASE WMOutStatus = 'Open NCR' ; LineColor = RED$ * CASE WMOutStatus = 'Cassette Rejected' ; LineColor = ORANGE$ * CASE 1 ; LineColor = WHITE$ * END CASE * * stat = Send_Message(CtrlName,'COLOR_BY_POS',0,I,LineColor) * NEXT I Ctrls = @WINDOW:'.TOT_ORD_ITEM_QTY':@RM ; Props = 'INVALUE':@RM Ctrls := @WINDOW:'.TOT_PRE_EPI_REJ':@RM ; Props := 'INVALUE':@RM Ctrls := @WINDOW:'.TOT_RDS_PROD_TEST':@RM ; Props := 'INVALUE':@RM Ctrls := @WINDOW:'.TOT_WFRS_OUT':@RM ; Props := 'INVALUE':@RM Ctrls := @WINDOW:'.TOT_MU_WFRS_OUT':@RM ; Props := 'INVALUE':@RM Ctrls := @WINDOW:'.TOT_POST_EPI_REJ' ; Props := 'INVALUE' Vals = Get_Property(Ctrls,Props) OrdQty = Vals[1,@RM] PreEpiRej = Vals[COL2()+1,@RM] ProdTest = Vals[COL2()+1,@RM] WfrsOut = Vals[COL2()+1,@RM] MUWfrsOut = Vals[COL2()+1,@RM] PostEpiRej = Vals[COL2()+1,@RM] * This section re-written 11/22/2011 JCH WONo = Get_Property(@WINDOW:'.WO_NO','DEFPROP') StepNo = Get_Property(@WINDOW:'.PROC_STEP_NO','DEFPROP') WOLogRec = XLATE('WO_LOG',WONo,'','X') WOMatKeys = WOLogRec WOWfrQty = SUM(XLATE('WO_MAT',WOMatKeys,WO_MAT_WAFER_QTY$,'X')) WOOrderQty = XLATE('WO_LOG',WONo,'TOT_ORD_ITEM_QTY','X') IF WOOrderQty = 0 THEN WOOrderQty = XLATE('WO_LOG',WONo,'WO_QTY','X') END WOLoadCnt = SUM(XLATE('WO_MAT',WOMatKeys,'WMI_RDS_LOAD_CNT','X')) WOPreEpiRej = SUM(XLATE('WO_MAT',WOMatKeys,'WM_IN_REJ_WFRS','X')) RRunNos = XLATE('WO_STEP',WONo:'*':StepNo,6,'X') WOUnloadCnt = SUM(XLATE('REACT_RUN',RRunNos,'EPI_PRO_UNLD_CNT','X')) WOPTCnt = SUM(XLATE('REACT_RUN',RRunNos,'EPI_PRO_PT_CNT','X')) IF WOLoadCnt > 0 THEN OrdPcntComp = ICONV(((WOPreEpiRej + WOUnloadCnt + WOPTCnt)/WOOrderQty)*100,'MD0') WipPcntComp = ICONV(((WOPreEpiRej + WOUnloadCnt + WOPTCnt)/WOWfrQty)*100,'MD0') END ELSE OrdPcntComp = 0 WipPcntComp = 0 END OrdPcntComp = 'Order - ':OCONV(OrdPcntComp,'MD0S%') WipPcntComp = 'WIP - ':OCONV(WipPcntComp,'MD0S%') Set_Property(@WINDOW:'.ORDER_PCNT','DEFPROP',OrdPcntComp) Set_Property(@WINDOW:'.WIP_PCNT','DEFPROP',WipPcntComp) * SAP interface update IF WONo NE '' THEN IF WOLogRec = '' OR WOLogRec = '' THEN CurrDTM = ICONV(OCONV(Date(),'D4/'):' ':OCONV(Time(),'MTH') ,'DT') ProdOrderNo = WOLogRec IF ProdOrderNo NE '' THEN IF WOLoadCnt >= 1 AND WOLogRec = '' THEN obj_Post_Log('Create','WO_LOG':@RM:WONo:@RM:WO_LOG_WO_START_DTM$:@RM:CurrDTM) END IF (WOPreEpiRej + WOUnloadCnt + WOPTCnt) >= WOOrderQty AND WOLogRec = '' THEN obj_Post_Log('Create','WO_LOG':@RM:WONo:@RM:WO_LOG_WO_STOP_DTM$:@RM:CurrDTM) END END END ;* End of check for WO_START and WO_STOP DTM's in WO Log record END * End of rewrite JCH * QBF buttons Ctrls = @WINDOW:'.QBF_FIRST_FIX':@RM ; Props = 'ENABLED':@RM Ctrls := @WINDOW:'.QBF_PREV_FIX':@RM ; Props := 'ENABLED':@RM Ctrls := @WINDOW:'.QBF_ABS_FIX':@RM ; Props := 'ENABLED':@RM Ctrls := @WINDOW:'.QBF_NEXT_FIX':@RM ; Props := 'ENABLED':@RM Ctrls := @WINDOW:'.QBF_LAST_FIX':@RM ; Props := 'ENABLED':@RM Ctrls := @WINDOW:'.QBF_STOP_FIX' ; Props := 'ENABLED' IF Get_Property(@WINDOW,'QBFLIST') = '' THEN Vals = 0:@RM:0:@RM:0:@RM:0:@RM:0:@RM:0 END ELSE Vals = 1:@RM:1:@RM:1:@RM:1:@RM:1:@RM:1 END Set_Property(Ctrls,Props,Vals) * Turn edit table symbolic column backgrounds to green ETSymbolics = Get_Property(@WINDOW,'@ET_SYMBOLICS') ;* Loaded during 'Create' in obj_Appwindow ETCtrls = ETSymbolics<1> ETCols = ETSymbolics<2> FOR I = 1 TO COUNT(ETCtrls,@VM) + (ETCtrls NE '') ETCtrl = ETCtrls<1,I> IF ETCtrl NE @WINDOW:'.RUNS' AND ETCtrl NE @WINDOW:'.WM_OUT' AND ETCtrl NE @WINDOW:'.WM_IN' THEN ETList = Get_Property(ETCtrl,'LIST') FOR Line = 1 TO COUNT(ETList,@FM) + (ETList NE '') IF ETList NE '' THEN FOR N = 1 TO COUNT(ETCols<1,I>,@SVM) + (ETCols<1,I> NE '') stat = Send_Message(ETCtrl,'COLOR_BY_POS',ETCols<1,I,N>,Line,GREEN$) NEXT N END NEXT Line END NEXT I RETURN * * * * * * * LUWONo: * * * * * * * Set_Status(0) WOKeys = obj_WO_Log('Find') IF Get_Status(errCode) THEN ErrMsg(ErrCode) IF WOKeys NE '' THEN TypeOver = '' TypeOver = WOKeys TypeOver = 'K' TypeOver = 1 WOKey = Popup(@WINDOW,TypeOver,'WO_LOG_QUERY') IF Get_Status(errCode) THEN ErrMsg(errCode) END IF WOKey NE '' THEN obj_Appwindow('LUValReturn',WOKey:@RM:@WINDOW:'.WO_NO':@RM:'') ;* Loads form key or QBFList as required END RETURN * * * * * * * StepGF: * * * * * * * WONo = Get_Property(@WINDOW:'.WO_NO','TEXT') WOStep = Get_Property(@WINDOW:'.PROC_STEP_NO','TEXT') IF WONo NE '' AND WOStep = '' THEN WOStepKeys = XLATE('WO_LOG',WONo,WO_LOG_WO_STEP_KEY$,'X') IF INDEX(WOStepKeys,@VM,1) THEN LastStep = WOStepKeys[-1,'B':@VM] WOStep = FIELD(LastStep,'*',2) END ELSE WOStep = FIELD(WOStepKeys,'*',2) END CurrControl = @WINDOW:'.PROC_STEP_NO' CurrPos = '' obj_Appwindow('LUValReturn',WOStep:@RM:CurrControl:@RM:CurrPos) END RETURN * * * * * * * ViewProdSpec: * * * * * * * IF Security_Check( 'Prod Spec', Read$ ) THEN PSNo = Get_Property(@WINDOW:'.PROD_SPEC_ID','DEFPROP') IF PSNo = '' THEN RETURN END ELSE Security_Err_Msg( 'Prod Spec', Read$ ) RETURN END * TechType = Xlate('PROD_SPEC', PSNo, 'TECH_TYPE', 'X') * Begin Case * Case TechType EQ 'P' Start_Window('DBW_PROD_SPEC_GAN', '', PSNo) * Case TechType EQ 'E' * Start_Window('PROD_SPEC', '', PSNo) * Case Otherwise$ * Start_Window('PROD_SPEC', '', PSNo) * End Case * obj_AppWindow('ViewRelated','PROD_SPEC':@RM:PSNo) * * Send_Event(@WINDOW:'.PS_NO','LOSTFOCUS') ;* Kicks the symbolics RETURN * * * * * * * OpenWOS: * * * * * * * IF Get_Property(@WINDOW:'.WO_NO','TEXT') NE '' THEN Send_Event(@WINDOW,'CLEAR') END OpenWONo = obj_WO_Log('OpenWONos','') IF OpenWONo NE '' THEN obj_AppWindow('LoadFormKeys',@WINDOW:@RM:OpenWONo) END RETURN * * * * * * * RdsDC: * * * * * * * CtrlEntID = @WINDOW:'.RUNS' CurrPos = Get_Property(CtrlEntID,'SELPOS') CurrCol = CurrPos<1> CurrRow = CurrPos<2> RDSNo = Get_Property(CtrlEntID,'CELLPOS',COL$RUNS_RDS_NO:@FM:CurrRow) WONo = Get_Property(@WINDOW:'.WO_NO','DEFPROP') WOStep = Get_Property(@WINDOW:'.PROC_STEP_NO','DEFPROP') IF WONo = '' OR WOStep = '' THEN RETURN WOStepKey = WONo:'*':WOStep IF RDSNo NE '' THEN PSNo = Get_Property(@Window:'.PROD_SPEC_ID', 'TEXT') TechType = Xlate('PROD_SPEC', PSNo, 'TECH_TYPE', 'X') Begin Case Case TechType EQ 'P' Start_Window('DBW_GAN_RDS_PROD', '', RDSNo) Case TechType EQ 'E' Start_Window('REACT_RUN', '', RDSNo) Case Otherwise$ Start_Window('REACT_RUN', '', RDSNo) End Case END RETURN * * * * * * * BrowseRDS: * * * * * * * WONo = Get_Property(@WINDOW:'.WO_NO','TEXT') StepNo = Get_Property(@WINDOW:'.PROC_STEP_NO','TEXT') IF WONo NE '' AND StepNo NE '' THEN WOStepKey = WONo:'*':StepNo END ELSE RETURN END CtrlEntID = @WINDOW:'.RUNS' CurrPos = Get_Property(CtrlEntID,'SELPOS') CurrCol = CurrPos<1> CurrRow = CurrPos<2> RDSNos = Get_Property(CtrlEntID,'ARRAY')<2> ;* Multivalue list of RDS Nos LOOP TestChar = RDSNos[-1,1] UNTIL TestChar NE @VM OR RDSNos = '' RDSNos[-1,1] = '' REPEAT IF RDSNos = '' THEN RETURN WONo = Get_Property(@Window:'.WO_NO', 'TEXT') RDSKeys = Dialog_Box('NDW_RDS_QUERY', @Window, WONo) IF RDSKeys = '' THEN RETURN Set_Property(@WINDOW,'@RETURN_FROM_RDS',WOStepKey) ;* Bullshit lashup to work with multiple RDS windows thisFormName = 'RDS' thisFormWindowUp = Get_Property(thisFormName,'VISIBLE') ;* Returns 0 = hidden, 1 = visible, 2 = minimized, 3 = maximized IF thisFormWindowUp = '' THEN If Get_Property('NDW_MAIN', 'VISIBLE') then AppMain = 'NDW_MAIN' end else AppMain = 'LSL_MAIN2' end Start_Window(thisFormName,AppMain,RDSKeys:'*CENTER', '', '') ;* Put up the card window RETURN END IF thisFormWindowUp = 2 THEN Set_Property(thisFormName,'VISIBLE',9) ;* Restore the window if minimized IF Get_Property(thisFormName,'SAVEWARN') THEN Send_Event(thisFormName,'CLEAR') ;* Clear anything existing (prompts for save first) END RETURN * * * * * * * WMInDC: * * * * * * * CtrlEntID = @WINDOW:'.WM_IN' CurrPos = Get_Property(CtrlEntID,'SELPOS') CurrCol = CurrPos<1> CurrRow = CurrPos<2> WONo = Get_Property(@WINDOW:'.WO_NO','DEFPROP') StepNo = Get_Property(@WINDOW:'.PROC_STEP_NO','DEFPROP') CassNo = Get_Property(CtrlEntID,'CELLPOS',1:@FM:CurrRow) IF WONo NE '' AND StepNo NE '' AND CassNo NE '' THEN DetWindow = 'WM_IN' DetKeys = WONo:'*':StepNo:'*':CassNo DefaultRec = '' RetKey = WONo:'*':StepNo RetPage = 1 RetCtrl = CtrlEntID RetPos = CurrPos oAParms = DetWindow:@RM:DetKeys:@RM:DefaultRec:@RM:RetKey:@RM:RetPage:@RM:RetCtrl:@RM:RetPos obj_AppWindow('ViewNewDetail',oAParms) IF Get_Status(errCode) THEN ErrMsg(errCode) END END RETURN * * * * * * * OutCassDC: * * * * * * * CtrlEntID = @WINDOW:'.OUT_WFRS' CurrPos = Get_Property(CtrlEntID,'SELPOS') CurrCol = CurrPos<1> CurrRow = CurrPos<2> WONo = Get_Property(@WINDOW:'.WO_NO','DEFPROP') StepNo = Get_Property(@WINDOW:'.PROC_STEP_NO','DEFPROP') CassNo = Get_Property(CtrlEntID,'CELLPOS',1:@FM:CurrRow) IF WONo NE '' AND StepNo NE '' AND CassNo NE '' THEN Send_Event(@WINDOW,'CLEAR') DetWindow = 'WO_MAT_GAN' DetKeys = WONo:'*':CassNo DefaultRec = '' RetKey = WONo:'*':StepNo RetPage = 1 RetCtrl = CtrlEntID RetPos = CurrPos oAParms = DetWindow:@RM:DetKeys:@RM:DefaultRec:@RM:RetKey:@RM:RetPage:@RM:RetCtrl:@RM:RetPos obj_AppWindow('ViewNewDetail',oAParms) IF Get_Status(errCode) THEN ErrMsg(errCode) END END RETURN * * * * * * * InCassDC: * * * * * * * If MemberOf(@USER4, 'OI_SUPERUSER') then CtrlEntID = @WINDOW:'.WO_MAT_KEYS' CurrPos = Get_Property(CtrlEntID,'SELPOS') CurrCol = CurrPos<1> CurrRow = CurrPos<2> WONo = Get_Property(@WINDOW:'.WO_NO','DEFPROP') CassNo = Get_Property(CtrlEntID,'CELLPOS',1:@FM:CurrRow) IF ( (WONo NE '') AND (CassNo NE '') ) THEN Start_Window('NDW_GAN_INBOUND_MATERIAL', @Window, WONo:'*':CassNo) END end return * * * * * * * CreateRDS: * * * * * * * CtrlEntID = @WINDOW:'.RUNS' WONo = Get_Property(@WINDOW:'.WO_NO','DEFPROP') WOStep = Get_Property(@WINDOW:'.PROC_STEP_NO','DEFPROP') IF WONo = '' OR WOStep = '' THEN RETURN WOStepKey = WONo:'*':WOStep IF @WINDOW = 'WO_PROD_EPI' THEN WMInRem = Get_Property(@WINDOW:'.WO_MAT_KEYS','ARRAY') ;* Just need remaining wafers column FOR NextCassNo = 1 TO COUNT(WMInRem,@VM) + (WMInRem NE '') UNTIL WMInRem<1,NextCassNo> > 0 NEXT NextCassNo END IF @WINDOW = 'WO_PROD_GAN' THEN WMInRem = Get_Property(@WINDOW:'.WO_MAT_KEYS','ARRAY') ;* Just need remaining wafers column FOR NextCassNo = 1 TO COUNT(WMInRem,@VM) + (WMInRem NE '') UNTIL WMInRem<1,NextCassNo> > 0 NEXT NextCassNo END Error_Services('Clear') RunNo = Work_Order_Services('GetNextRunNo', WONo, WOStep) If Error_Services('HasError') then ErrorMsg = Error_Services('GetMessage') ErrMsg('An error occurred creating an RDS. Please contact FI Support. ':ErrorMsg) Return end IF RunNo = '' THEN RETURN WOMatKey = WONo:'*':NextCassNo WOMatRec = XLATE('WO_MAT',WOMatKey,'','X') CassLotNo = WOMatRec CassWaferQty = '0' CassPartNo = WOMatRec CassSubPartNo = WOMatRec CassSubInvID = '' ;* This isn't being used CassOrderItem = WOMatRec WORec = XLATE('WO_LOG',WONo,'','X') OrderNo = WORec CustNo = WORec PromiseDt = WORec PONo = XLATE('ORDER',OrderNo,ORDER_PO_NO$,'X') QuoteNo = XLATE('ORDER_DET',OrderNo:'*':CassOrderItem,ORDER_DET_QUOTE_NO$,'X') WOStepCnt = COUNT(WORec,@VM) + (WORec NE '') WOStepKey = WONo:'*':WOStep IF WOStepKey = WORec[-1,'B':@VM] THEN LastStep = 1 END ELSE LastStep = 0 END PSN = XLATE('WO_STEP',WOStepKey,WO_STEP_PROD_SPEC_ID$,'X') *SubstrateSpec = XLATE('PROD_SPEC',PSN,PROD_SPEC_SPEC_SUBSTRATE$,'X') ReactorType = XLATE('PROD_SPEC',PSN,PROD_SPEC_REACTOR_TYPE$,'X') ;* Not used in program JCH 8/28/2014 EpiPN = XLATE('WO_LOG',WONo,WO_LOG_EPI_PART_NO$,'X') SubSupplyBy = XLATE('EPI_PART',EpiPN,EPI_PART_SUB_SUPP_BY$,'X') ;*SubstrateSpec<1,QSSubWafersSupBy$> SubPreClean = XLATE('PRS_STAGE',PSN:'*PRE',PRS_STAGE_CLEAN_TOOL$,'X') ;*SubstrateSpec<1,QSSubPreClean$> SubPostClean = XLATE('PRS_STAGE',PSN:'*POST',PRS_STAGE_CLEAN_TOOL$,'X') ;*SubstrateSpec<1,QSSubPostClean$> OrgColor = Set_Property(@WINDOW:'.STATUS_LINE','BACKCOLOR',YELLOW$) Parms = WONo:@RM Parms := WOStep:@RM Parms := LastStep:@RM Parms := RunNo:@RM ; * Was NextCassNo Parms := QuoteNo:@RM Parms := OrderNo:@RM Parms := CassOrderItem:@RM Parms := CustNo:@RM Parms := PONo:@RM Parms := PSN:@RM Parms := SubSupplyBy:@RM Parms := SubPreClean:@RM Parms := SubPostClean:@RM Parms := PromiseDt:@RM Parms := CassLotNo:@RM Parms := CassPartNo:@RM Parms := CassWaferQty:@RM Parms := CassSubPartNo RDSNo = obj_RDS('Create',Parms) PSRec = XLATE('PROD_SPEC',PSN,'','X') RunStages = GaN_Services('GetCassStages', RDSNo) ; // Cassette Stages WfrStages = GaN_Services('GetWfrStages', RDSNo) ; // Wafer Stages rsCnt = COUNT(RunStages,@VM) + (RunStages NE '') RunStageKeys = '' FOR R = 1 TO rsCnt Stage = RunStages<1,R> RunStageKeys<1,R> = RDSNO:'*':Stage obj_Run_Stage('Create',RDSNo:@RM:Stage:@RM:PSN) ;* Create new RUN_STAGE records for each stage NEXT R otParms = 'REACT_RUN':@RM:RDSNo RRunRec = obj_Tables('ReadRec',otParms) IF Get_Status(errCode) THEN ErrMsg(errCode) END ELSE RRunRec = RunStageKeys RRunRec = WfrStages otParms = FieldStore(otParms,@RM,4,0,RRunRec) obj_Tables('WriteRec',otParms) IF Get_Status(errCode) THEN ErrMsg(errCode) END END IF Get_Status(errCode) THEN ErrMsg(errCode) obj_Appwindow('LoadFormKeys',@WINDOW:@RM:WOStepKey) RETURN END Send_Info(STR(' ',100)) Dummy = Set_Property(@WINDOW:'.STATUS_LINE','BACKCOLOR',OrgColor) IF RDSNo NE '' THEN PSNo = Get_Property(@Window:'.PROD_SPEC_ID', 'TEXT') TechType = Xlate('PROD_SPEC', PSNo, 'TECH_TYPE', 'X') Begin Case Case TechType EQ 'P' Start_Window('DBW_GAN_RDS_PROD', '', RDSNo) Case TechType EQ 'E' Start_Window('REACT_RUN', '', RDSNo) Case Otherwise$ Start_Window('REACT_RUN', '', RDSNo) End Case END Post_Event('WO_PROD_GAN', 'READ') RETURN * * * * * * * RemWMOut: * * * * * * * RETURN WONo = Get_Property(@WINDOW:'.WO_NO','TEXT') IF WONo = '' THEN RETURN *Send_Event(@WINDOW,'WRITE') WORec = XLATE('WO_LOG',WONo,'','X') WOMatKeys = WORec WMOutKeys = XLATE('WO_MAT',WOMatKeys,WO_MAT_WMO_KEY$,'X') WMOutCnt = COUNT(WMOutKeys,@VM) + (WMOutKeys NE '') Display = '' DispLine = 1 IF WMOutCnt > 0 THEN FOR I = WMOutCnt TO 1 STEP -1 WMORec = XLATE('WM_OUT',WMOutKeys<1,I>,'','X') WMO_RdsNos = WMORec WMO_NCRNos = WMORec WMO_UMWCassIDs = WMORec CONVERT @VM TO '' IN WMO_RdsNos CONVERT @VM TO '' IN WMO_NCRNos CONVERT @VM TO '' IN WMO_UMWCassIDs UNTIL WMO_RdsNos NE '' OR WMO_NCRNos NE '' OR WMO_UMWCassIDs NE '' Display<1,DispLine,1> = FIELD(WOMatKeys<1,I>,'*',2) Display<1,DispLine,2> = OCONV(obj_WM_Out('CurrStatus',WOMatKeys<1,I>:@RM:WMORec),'[WO_MAT_CURR_STATUS_CONV]') Display<1,DispLine,3> = WMOutKeys<1,I> DispLine += 1 NEXT I IF Display NE '' THEN TypeOver = '' TypeOver = Display TypeOver = 'Unused WM_OUT Cassettes' WMOData = Popup(@WINDOW,TypeOver,'UNUSED_WM_OUT') IF WMOData = '' OR WMOData = CHAR(27) THEN RETURN ;* Cancelled out END ELSE ErrMsg('All cassettes on this Work Order have started processing.') obj_AppWindow('LoadFormKeys',@WINDOW:@RM:WONo) RETURN END DelWMOutKeys = '' FOR I = 1 TO COUNT(WMOData,@FM) + (WMOData NE '') DelWMOutKeys<1,I> = WMOData NEXT I TestWMOutKeys = DelWMOutKeys CONVERT @VM TO '' IN TestWMOutKeys IF TestWMOutKeys NE '' THEN Set_Status(0) obj_WM_Out('Delete',DelWMOutKeys) IF Get_Status(errCode) THEN ErrMsg(errCode) END END IF Get_Status(errCode) THEN ErrMsg(errCode) END END IF Display = '' THEN ErrMsg('All cassettes on this Work Order have had wafers placed in them.') RETURN END IF Get_Status(errCode) THEN ErrMsg(errCode) END *obj_AppWindow('LoadFormKeys',@WINDOW:@RM:WONo) Send_Event(@WINDOW,'READ') RETURN * * * * * * * WaferTrace: * * * * * * * WONo = Get_Property(@WINDOW:'.WO_NO','TEXT') IF WONo = '' THEN RETURN CALL Reconcile_EPI_Wo(WONo) RETURN * * * * * * * ControlPlan: * * * * * * * WONo = Get_Property(@WINDOW:'.WO_NO','DEFPROP') PSNo = Get_Property(@WINDOW:'.PROD_SPEC_ID','DEFPROP') IF PSNo NE '' AND WONo NE '' THEN Print_Control_Plan(PSNo,WONo) END RETURN * * * * * * * ViewWorkOrder: * * * * * * * WONo = Get_Property(@WINDOW:'.WO_NO','TEXT') If WONo NE '' then NewForm = Xlate('APP_INFO', 'NEW_WO_FORM', '', 'X') If NewForm then Form = 'NDW_WO_LOG' end else Form = 'WO_LOG2' end Parent = Get_Property(@Window, 'PARENT') Start_Window(Form, Parent, WONo) end return * * * * * * * AddOutboundCass: WONo = Get_Property(@WINDOW:'.WO_NO','TEXT') If WONo NE '' then Def = "" Def = "Creating outbound cassettee..." Def = "U" MsgUp = Msg(@window, Def) ;* display the processing message Work_Order_Services('CreateOutbound', WONo) Post_Event('WO_PROD_GAN', 'READ') Msg(@window, MsgUp) ;* take down the processing message end return * * * * * * *