17 Commits

Author SHA1 Message Date
bf82640ed2 Common ResourceID and IsViewerFile
Enable process-data-standard-format for HgCV and Tencor
2025-06-03 13:26:49 -07:00
292bc4646b Merged PR 17058: Start sending 10 point thickness runs to InfinityQS
Start sending 10 point thickness runs to InfinityQS by copying the logic of the 14 point

Related work items: #255371, #255376
2025-05-21 21:34:30 +02:00
f4c1a42812 Merged PR 15667: process-data-standard-format prep without making any changes
process-data-standard-format prep without making any changes
2025-05-20 21:27:19 +02:00
b2edf6f288 Merged PR 15600: Switch to InfinityQS server messa04ec.infineon.com to allow the SPC MI to sav...
Switch to InfinityQS server messa04ec.infineon.com to allow the SPC MI to save locally
2025-04-28 18:13:16 +02:00
Ouellette Jonathan (CSC FI SPS MESLEO)
d626ebdf3c Merged PR 15381: EPP BioRad Data Import BugFix 2025-04-21 22:26:15 +02:00
Ouellette Jonathan (CSC FI SPS MESLEO)
f8c96150f5 Merged PR 13911: Allow 7 Digit RDS keys for Tencor and SP1
Removed conditional checks that ensured RDS keys were 6 chars or less from Tencor and SP1 Import routines. Needed to ensure 7 digit rds id's will be compatible with respective metrology import.

Related work items: #225670, #247866, #247867
2025-03-27 22:26:35 +01:00
Ouellette Jonathan (CSC FI SPS MESLEO)
2ac49b85ec Merged PR 13708: Found small bug in HgCV data upload where the variable used in LoadRunDataToD...
Found small bug in HgCV data upload where the variable used in LoadRunDataToDatabase was being nulled out in calling service function.
2025-03-25 21:06:49 +01:00
Infineon\StieberD
9d46c179b1 initialized prof step variable to avoid VNAV 2025-02-10 11:12:38 -07:00
Infineon\StieberD
790d3e7b8c disabling missing auto calculated data notifications 2025-02-04 09:08:25 -07:00
Infineon\StieberD
ab8f9d3c24 Alarm trigger with NICA_ORDERS table
solution tested and ready for deployment

updated SRP_Git_Services to handle creating local copies of inherited entities

updated HgCV OCAP order trigger to also look for active prove-in orders

moved error services common into sysprog to avoid compilation issues
2025-01-20 12:25:09 -07:00
Chase Tucker
0c2a5770a9 recipe and pattern validation on Biorad imports 2024-12-10 09:42:24 -07:00
Chase Tucker
526b9943a0 enable multi layer non EpiPro BioRad imports 2024-11-18 17:52:53 +01:00
Infineon\StieberD
f7ca1f765b added datetime to HgCV SPC file as well as logging 2024-10-23 14:54:12 -07:00
Infineon\StieberD
2dc8a264c2 updated 100% stratus to auto calculate std dev 2024-09-20 03:00:54 +02:00
Infineon\StieberD
7762b129af pre cutover push 2024-09-04 20:33:41 -07:00
Infineon\StieberD
6ea6969f4b getting repo caught up 2024-05-22 14:06:46 -07:00
Infineon\StieberD
c667dd56eb added LSL2 stored procedures 2024-03-25 14:46:21 -07:00