Modified QA met complete check before wafer counter to only apply to FQA location scans

This commit is contained in:
Infineon\StieberD
2025-09-19 11:48:46 -07:00
committed by Stieber Daniel (CSC FI SPS MESLEO)
parent 9d6c4c154f
commit c183da951a

View File

@ -97,16 +97,6 @@ Event WINDOW.CREATE(CreateParam)
LogData<5> = ToolLoc
LogData<6> = @Window:'.CREATE'
Logging_Services('AppendLog', objLog, LogData, @RM, @FM)
QAMetComplete = ''
If CassID NE '' then
If RowExists('WM_OUT', CassID) then
WOMatKey = Xlate('WM_OUT', CassID, 'WO_MAT_KEY', 'X')
end else
WOMatKey = Xlate('RDS', CassID, 'WO_MAT_KEY', 'X')
end
QAMetComplete = Wo_Mat_Qa_Services('GetQAMetComplete', WOMatKey)
end
Convert '.' to '*' in CassID
ExpectedQty = ''
@ -115,8 +105,6 @@ Event WINDOW.CREATE(CreateParam)
Set_Property(@Window:'.EDL_CASS_ID', 'TEXT', CassID)
Begin Case
Case (CassID NE '' AND QAMetComplete EQ False$)
ErrorMsg = 'Wafer Counter Operation Not Allowed. QA Metrology Incomplete.'
Case ( (CassID EQ '') and (ToolLoc EQ '') )
// Alternate workflow
Set_Property(@Window:'.LBL_CASS_ID', 'TEXT', 'Cass ID')
@ -333,8 +321,6 @@ Event EDL_CASS_BARCODE.LOSTFOCUS(Flag, FocusID)
Begin Case
Case RowExists('RDS', CassetteID)
WOMatKey = Xlate('RDS', CassetteID, 'WO_MAT_KEY', 'X')
QAMetComplete = Wo_Mat_Qa_Services('GetQAMetComplete', WOMatKey)
If QAMetComplete EQ True$ then
ExpectedQty = Xlate('RDS', CassetteID, 'WFRS_OUT', 'X')
Set_Property(@Window:'.EDL_EXPECTED_QTY', 'TEXT', ExpectedQty)
Set_Property(@Window:'.LBL_CASS_ID', 'TEXT', 'Cass RDS')
@ -347,14 +333,9 @@ Event EDL_CASS_BARCODE.LOSTFOCUS(Flag, FocusID)
end else
ErrorMsg = Error_Services('GetMessage')
end
end else
ErrorMsg = 'Wafer Counter Operation Not Allowed. A Metrology stage is incomplete.'
end
Case RowExists('WM_OUT', CassetteID)
WOMatKey = Xlate('WM_OUT', CassetteID, 'WO_MAT_KEY', 'X')
QAMetComplete = Wo_Mat_Qa_Services('GetQAMetComplete', WOMatKey)
If QAMetComplete EQ True$ then
ExpectedQty = Xlate('WM_OUT', CassetteID, 'WAFER_CNT', 'X')
Set_Property(@Window:'.EDL_EXPECTED_QTY', 'TEXT', ExpectedQty)
Set_Property(@Window:'.LBL_CASS_ID', 'TEXT', 'Cass WMO')
@ -366,9 +347,6 @@ Event EDL_CASS_BARCODE.LOSTFOCUS(Flag, FocusID)
end else
ErrorMsg = Error_Services('GetMessage')
end
end else
ErrorMsg = 'Wafer Counter Operation Not Allowed. QA Metrology Incomplete.'
end
End Case
If ErrorMsg EQ '' then
@ -438,7 +416,53 @@ Event EDL_TOOL_BARCODE.LOSTFOCUS(Flag, FocusID)
Cnt = DCount(ScanData, '|')
If Cnt EQ 2 then
WaferSize = Field(ScanData, '|', 1)
Area = Field(ScanData, '|', 2)
Area = Field(ScanData, '|', 2) ; // This is a proxy for the operation being performed
If Area EQ 'FQA' then
CassetteID = Get_Property(@Window:'.EDL_CASS_ID', 'TEXT')
Begin Case
Case RowExists('RDS', CassetteID)
WOMatKey = Xlate('RDS', CassetteID, 'WO_MAT_KEY', 'X')
QAMetComplete = Wo_Mat_Qa_Services('GetQAMetComplete', WOMatKey)
If QAMetComplete EQ True$ then
ExpectedQty = Xlate('RDS', CassetteID, 'WFRS_OUT', 'X')
Set_Property(@Window:'.EDL_EXPECTED_QTY', 'TEXT', ExpectedQty)
Set_Property(@Window:'.LBL_CASS_ID', 'TEXT', 'Cass RDS')
Set_Property(@Window:'.LBL_CASS_BARCODE', 'TEXT', 'Cass RDS 2D')
WOMatKey = Xlate('RDS', CassetteID, 'WO_MAT_KEY', 'X')
CurrWfrMap = WO_Mat_Services('GetWaferMap', WOMatKey)
If Error_Services('NoError') then
ExpectedWfrMap = CurrWfrMap
end else
ErrorMsg = Error_Services('GetMessage')
end
end else
ErrorMsg = 'Wafer Counter Operation Not Allowed. A Metrology stage is incomplete.'
end
Case RowExists('WM_OUT', CassetteID)
WOMatKey = Xlate('WM_OUT', CassetteID, 'WO_MAT_KEY', 'X')
QAMetComplete = Wo_Mat_Qa_Services('GetQAMetComplete', WOMatKey)
If QAMetComplete EQ True$ then
ExpectedQty = Xlate('WM_OUT', CassetteID, 'WAFER_CNT', 'X')
Set_Property(@Window:'.EDL_EXPECTED_QTY', 'TEXT', ExpectedQty)
Set_Property(@Window:'.LBL_CASS_ID', 'TEXT', 'Cass WMO')
Set_Property(@Window:'.LBL_CASS_BARCODE', 'TEXT', 'Cass WMO 2D')
CurrWfrMap = WM_Out_Services('GetWaferMap', CassetteID)
If Error_Services('NoError') then
ExpectedWfrMap = CurrWfrMap
end else
ErrorMsg = Error_Services('GetMessage')
end
end else
ErrorMsg = 'Wafer Counter Operation Not Allowed. QA Metrology Incomplete.'
end
End Case
end
If ErrorMsg EQ '' then
Def = ""
Def<MTEXT$> = "Retreiving Wafer Counter Data..."
Def<MTYPE$> = "U"
@ -531,17 +555,16 @@ Event EDL_TOOL_BARCODE.LOSTFOCUS(Flag, FocusID)
end else
ErrorMsg = Error_Services('GetMessage')
end
end
end else
ErrorMsg = 'Invalid Tool Barcode Scan.'
end
end else
LogData = ''
LogData<1> = OConv(Datetime(), 'DT2/^H')
LogData<2> = @User4
LogData<3> = 'Verification process canceled'
Logging_Services('AppendLog', objLog, LogData, @RM, @FM)
End_Dialog(@Window, False$)
end
If ErrorMsg NE '' then
@ -624,9 +647,3 @@ ClearForm:
return