fixed material track report, Mona_Services HTTP call, and COC file generation
This commit is contained in:
committed by
Infineon\StieberD
parent
7762b129af
commit
a8a9e91d04
@ -1,120 +1,120 @@
|
||||
Compile function NDW_PM_OVERRIDE_EVENTS(CtrlEntId, Event, @PARAMS)
|
||||
/***********************************************************************************************************************
|
||||
|
||||
This program is proprietary and is not to be used by or disclosed to others, nor is it to be copied without written
|
||||
permission from Infineon.
|
||||
|
||||
Name : NDW_PM_Override_Events
|
||||
|
||||
Description : This function acts as a commuter module for all events related to this window.
|
||||
|
||||
Notes : Commuter Modules are automatically called from the Promoted_Events function which is called by the
|
||||
application-specific promoted event handler. This makes it possible to add QuickEvents that need to
|
||||
execute Basic+ logic without having use the Form Designer to make the association, although this is
|
||||
limited to the events which are currently promoted.
|
||||
|
||||
If the form needs to call the commuter module directly then the QuickEvent parameters should be
|
||||
formatted like this:
|
||||
|
||||
'@SELF','@EVENT',['@PARAM1','@PARAMx']
|
||||
|
||||
Parameters :
|
||||
CtrlEntId [in] -- The fully qualified name of the control calling the promoted event
|
||||
Event [in] -- The event being executed. See the Notes section regarding "PRE" events
|
||||
Param1-15 [in] -- Additional event parameter holders
|
||||
EventFlow [out] -- Set to 1 or 0 so the calling event knows whether or not to chain forward. See comments in
|
||||
EVENT_SETUP insert
|
||||
|
||||
History : (Date, Initials, Notes)
|
||||
06/25/24 djs Created initial commuter module.
|
||||
|
||||
***********************************************************************************************************************/
|
||||
#pragma precomp SRP_PreCompiler
|
||||
#window NDW_PM_OVERRIDE
|
||||
|
||||
$Insert APP_INSERTS
|
||||
$Insert EVENT_SETUP
|
||||
$Insert REACTOR_LOG_EQUATES
|
||||
$insert MESSAGE_BOX_EQUATES
|
||||
|
||||
Declare subroutine Placedialog, Message_Box
|
||||
|
||||
// Update the arguments so that the OpenInsight OLE event will treate the ActiveX event as a native event handler.
|
||||
If Event EQ 'OLE' then
|
||||
Transfer Event to OIEvent
|
||||
Transfer Param1 to Event
|
||||
Transfer Param2 to Param1
|
||||
Transfer Param3 to Param2
|
||||
Transfer Param4 to Param3
|
||||
Transfer Param5 to Param4
|
||||
Transfer Param6 to Param5
|
||||
Transfer Param7 to Param6
|
||||
Transfer Param8 to Param7
|
||||
end
|
||||
|
||||
GoToEvent Event for CtrlEntId else
|
||||
// Event not implemented
|
||||
end
|
||||
|
||||
Return EventFlow or 1
|
||||
|
||||
//-----------------------------------------------------------------------------
|
||||
// EVENT HANDLERS
|
||||
//-----------------------------------------------------------------------------
|
||||
|
||||
Event WINDOW.CREATE(CreateParam)
|
||||
|
||||
RlNo = CreateParam
|
||||
PmOrderTypes = Xlate('REACTOR_LOG', RLNo, REACTOR_LOG_CHECKLIST_TYPE$, 'X')
|
||||
for each PmOrderType in PmOrderTypes using @VM setting dummy
|
||||
Begin Case
|
||||
Case PmOrderType _EQC 'ASM_HTR_TUBE_CHANGE'
|
||||
Set_Property(@Window:'.CHB_ASM_HTR_TUBE_CHANGE', 'ENABLED', True$)
|
||||
Case PmOrderType _EQC 'SEMIANNUAL_PM'
|
||||
Set_Property(@Window:'.CHB_SEMIANNUAL_PM', 'ENABLED', True$)
|
||||
Case PmOrderType _EQC 'ANNUAL_PM'
|
||||
Set_Property(@Window:'.CHB_ANNUAL_PM', 'ENABLED', True$)
|
||||
Case Otherwise$
|
||||
Null
|
||||
End Case
|
||||
Next PmOrderType
|
||||
|
||||
Placedialog(-2, -2)
|
||||
|
||||
End Event
|
||||
|
||||
|
||||
Event PUB_SUBMIT.CLICK()
|
||||
|
||||
OverrideData = ''
|
||||
SelectedTypes = ''
|
||||
If Get_Property(@Window:'.CHB_ASM_HTR_TUBE_CHANGE', 'CHECK') then SelectedTypes<0, -1> = "ASM_HTR_TUBE_CHANGE"
|
||||
If Get_Property(@Window:'.CHB_SEMIANNUAL_PM', 'CHECK') then SelectedTypes<0, -1> = 'SEMIANNUAL_PM'
|
||||
If Get_Property(@Window:'.CHB_ANNUAL_PM', 'CHECK') then SelectedTypes<0, -1> = 'ANNUAL_PM'
|
||||
|
||||
If SelectedTypes EQ '' then
|
||||
Message_Box(@Window, "You must select at least one PM type!", "Error", MSG_ICON_EXCLAM$)
|
||||
return
|
||||
end else
|
||||
OverrideData<1, 1> = SelectedTypes
|
||||
end
|
||||
|
||||
OverrideData<2, 1> = Get_Property(@Window:'.EDB_COMMENT', 'TEXT')
|
||||
|
||||
If OverrideData<2, 1> EQ '' or Len(OverrideData<2, 1>) LT 4 then
|
||||
Message_Box(@Window, "Your comment must be at least 4 characters!", "Error", MSG_ICON_EXCLAM$)
|
||||
return
|
||||
end
|
||||
|
||||
End_Dialog(@Window, OverrideData)
|
||||
|
||||
end event
|
||||
|
||||
|
||||
Event PUB_CANCEL.CLICK()
|
||||
|
||||
End_Dialog(@Window, '')
|
||||
|
||||
end event
|
||||
|
||||
|
||||
Compile function NDW_PM_OVERRIDE_EVENTS(CtrlEntId, Event, @PARAMS)
|
||||
/***********************************************************************************************************************
|
||||
|
||||
This program is proprietary and is not to be used by or disclosed to others, nor is it to be copied without written
|
||||
permission from Infineon.
|
||||
|
||||
Name : NDW_PM_Override_Events
|
||||
|
||||
Description : This function acts as a commuter module for all events related to this window.
|
||||
|
||||
Notes : Commuter Modules are automatically called from the Promoted_Events function which is called by the
|
||||
application-specific promoted event handler. This makes it possible to add QuickEvents that need to
|
||||
execute Basic+ logic without having use the Form Designer to make the association, although this is
|
||||
limited to the events which are currently promoted.
|
||||
|
||||
If the form needs to call the commuter module directly then the QuickEvent parameters should be
|
||||
formatted like this:
|
||||
|
||||
'@SELF','@EVENT',['@PARAM1','@PARAMx']
|
||||
|
||||
Parameters :
|
||||
CtrlEntId [in] -- The fully qualified name of the control calling the promoted event
|
||||
Event [in] -- The event being executed. See the Notes section regarding "PRE" events
|
||||
Param1-15 [in] -- Additional event parameter holders
|
||||
EventFlow [out] -- Set to 1 or 0 so the calling event knows whether or not to chain forward. See comments in
|
||||
EVENT_SETUP insert
|
||||
|
||||
History : (Date, Initials, Notes)
|
||||
06/25/24 djs Created initial commuter module.
|
||||
|
||||
***********************************************************************************************************************/
|
||||
#pragma precomp SRP_PreCompiler
|
||||
#window NDW_PM_OVERRIDE
|
||||
|
||||
$Insert APP_INSERTS
|
||||
$Insert EVENT_SETUP
|
||||
$Insert REACTOR_LOG_EQUATES
|
||||
$insert MESSAGE_BOX_EQUATES
|
||||
|
||||
Declare subroutine Placedialog, Message_Box
|
||||
|
||||
// Update the arguments so that the OpenInsight OLE event will treate the ActiveX event as a native event handler.
|
||||
If Event EQ 'OLE' then
|
||||
Transfer Event to OIEvent
|
||||
Transfer Param1 to Event
|
||||
Transfer Param2 to Param1
|
||||
Transfer Param3 to Param2
|
||||
Transfer Param4 to Param3
|
||||
Transfer Param5 to Param4
|
||||
Transfer Param6 to Param5
|
||||
Transfer Param7 to Param6
|
||||
Transfer Param8 to Param7
|
||||
end
|
||||
|
||||
GoToEvent Event for CtrlEntId else
|
||||
// Event not implemented
|
||||
end
|
||||
|
||||
Return EventFlow or 1
|
||||
|
||||
//-----------------------------------------------------------------------------
|
||||
// EVENT HANDLERS
|
||||
//-----------------------------------------------------------------------------
|
||||
|
||||
Event WINDOW.CREATE(CreateParam)
|
||||
|
||||
RlNo = CreateParam
|
||||
PmOrderTypes = Xlate('REACTOR_LOG', RLNo, REACTOR_LOG_CHECKLIST_TYPE$, 'X')
|
||||
for each PmOrderType in PmOrderTypes using @VM setting dummy
|
||||
Begin Case
|
||||
Case PmOrderType _EQC 'ASM_HTR_TUBE_CHANGE'
|
||||
Set_Property(@Window:'.CHB_ASM_HTR_TUBE_CHANGE', 'ENABLED', True$)
|
||||
Case PmOrderType _EQC 'SEMIANNUAL_PM'
|
||||
Set_Property(@Window:'.CHB_SEMIANNUAL_PM', 'ENABLED', True$)
|
||||
Case PmOrderType _EQC 'ANNUAL_PM'
|
||||
Set_Property(@Window:'.CHB_ANNUAL_PM', 'ENABLED', True$)
|
||||
Case Otherwise$
|
||||
Null
|
||||
End Case
|
||||
Next PmOrderType
|
||||
|
||||
Placedialog(-2, -2)
|
||||
|
||||
End Event
|
||||
|
||||
|
||||
Event PUB_SUBMIT.CLICK()
|
||||
|
||||
OverrideData = ''
|
||||
SelectedTypes = ''
|
||||
If Get_Property(@Window:'.CHB_ASM_HTR_TUBE_CHANGE', 'CHECK') then SelectedTypes<0, -1> = "ASM_HTR_TUBE_CHANGE"
|
||||
If Get_Property(@Window:'.CHB_SEMIANNUAL_PM', 'CHECK') then SelectedTypes<0, -1> = 'SEMIANNUAL_PM'
|
||||
If Get_Property(@Window:'.CHB_ANNUAL_PM', 'CHECK') then SelectedTypes<0, -1> = 'ANNUAL_PM'
|
||||
|
||||
If SelectedTypes EQ '' then
|
||||
Message_Box(@Window, "You must select at least one PM type!", "Error", MSG_ICON_EXCLAM$)
|
||||
return
|
||||
end else
|
||||
OverrideData<1, 1> = SelectedTypes
|
||||
end
|
||||
|
||||
OverrideData<2, 1> = Get_Property(@Window:'.EDB_COMMENT', 'TEXT')
|
||||
|
||||
If OverrideData<2, 1> EQ '' or Len(OverrideData<2, 1>) LT 4 then
|
||||
Message_Box(@Window, "Your comment must be at least 4 characters!", "Error", MSG_ICON_EXCLAM$)
|
||||
return
|
||||
end
|
||||
|
||||
End_Dialog(@Window, OverrideData)
|
||||
|
||||
end event
|
||||
|
||||
|
||||
Event PUB_CANCEL.CLICK()
|
||||
|
||||
End_Dialog(@Window, '')
|
||||
|
||||
end event
|
||||
|
||||
|
||||
|
Reference in New Issue