updated WO_MAT_ACTIONS to block write operations if certain fields are cleared
This commit is contained in:
committed by
Stieber Daniel (CSC FI SPS MESLEO)
parent
d570e3cfef
commit
3becd9cf4d
@ -266,321 +266,371 @@ return
|
||||
|
||||
WRITE_RECORD_PRE:
|
||||
|
||||
WOMatKeyID = Name
|
||||
OrigRDSNo = OrigRecord<WO_MAT_RDS_NO$>
|
||||
NewRDSNo = Record<WO_MAT_RDS_NO$>
|
||||
WOMatKeyID = Name
|
||||
OrigRDSNo = OrigRecord<WO_MAT_RDS_NO$>
|
||||
NewRDSNo = Record<WO_MAT_RDS_NO$>
|
||||
OrigLotNo = OrigRecord<WO_MAT_LOT_NO$>
|
||||
NewLotNo = Record<WO_MAT_LOT_NO$>
|
||||
OrigWfrQty = OrigRecord<WO_MAT_WAFER_QTY$>
|
||||
NewWfrQty = Record<WO_MAT_WAFER_QTY$>
|
||||
OrigCustPartNo = OrigRecord<WO_MAT_CUST_PART_NO$>
|
||||
NewCustPartNo = Record<WO_MAT_CUST_PART_NO$>
|
||||
OrigSubPartNo = OrigRecord<WO_MAT_SUB_PART_NO$>
|
||||
NewSubPartNo = Record<WO_MAT_SUB_PART_NO$>
|
||||
OrigInvActions = OrigRecord<WO_MAT_INV_ACTION$>
|
||||
OrigNumActions = DCount(OrigInvActions, @VM)
|
||||
NewInvActions = Record<WO_MAT_INV_ACTION$>
|
||||
NewNumActions = DCount(NewInvActions, @VM)
|
||||
OrigSlotNos = OrigRecord<WO_MAT_SLOT_NO$>
|
||||
OrigNumSlotNos = DCount(OrigSlotNos, @VM)
|
||||
NewSlotNos = Record<WO_MAT_SLOT_NO$>
|
||||
NewNumSlotNos = DCount(NewSlotNos, @VM)
|
||||
OrigRxDtm = OrigRecord<WO_MAT_RX_DTM$>
|
||||
NewRxDtm = Record<WO_MAT_RX_DTM$>
|
||||
OrigRxBy = OrigRecord<WO_MAT_RX_BY$>
|
||||
NewRxBy = Record<WO_MAT_RX_BY$>
|
||||
OrigRelDtm = OrigRecord<WO_MAT_REL_DTM$>
|
||||
NewRelDtm = Record<WO_MAT_REL_DTM$>
|
||||
OrigRelBy = OrigRecord<WO_MAT_REL_BY$>
|
||||
NewRelBy = Record<WO_MAT_REL_BY$>
|
||||
OrigSubVendCd = OrigRecord<WO_MAT_SUB_VEND_CD$>
|
||||
NewSubVendCd = Record<WO_MAT_SUB_VEND_CD$>
|
||||
OrigCassShipQty = OrigRecord<WO_MAT_CASS_SHIP_QTY$>
|
||||
NewCassShipQty = Record<WO_MAT_CASS_SHIP_QTY$>
|
||||
OrigShipShort = OrigRecord<WO_MAT_SHIP_SHORT$>
|
||||
NewShipShort = Record<WO_MAT_SHIP_SHORT$>
|
||||
OrigMuWaferFlag = OrigRecord<WO_MAT_MU_WAFER_FLAG$>
|
||||
NewMuWaferFlag = Record<WO_MAT_MU_WAFER_FLAG$>
|
||||
|
||||
If OrigRDSNo NE '' and NewRDSNo EQ '' and Not(MemberOf(@User4, 'OI_ADMIN')) then
|
||||
|
||||
Record<WO_MAT_RDS_NO$> = OrigRDSNo
|
||||
SaveRecord = Record
|
||||
LogData = ''
|
||||
LogData<1> = LoggingDTM
|
||||
LogData<2> = @USER4
|
||||
LogData<3> = OrigRDSNo
|
||||
LogData<4> = WOMatKeyID
|
||||
If OrigRDSNo NE '' then
|
||||
LogData<5> = Xlate('RDS', OrigRDSNo, 'WO_MAT_KEY', 'X')
|
||||
end else
|
||||
LogData<5> = ''
|
||||
end
|
||||
LogData<6> = 'RDS number cannot be removed. Setting RDS number back.'
|
||||
Machine = Environment_Services('GetServer')
|
||||
Logging_Services('AppendLog', ObjLog3, LogData, @RM, @FM, False$)
|
||||
If ( ( (OrigRDSNo NE '') and (NewRDSNo EQ '') ) or ( (OrigLotNo NE '') and (NewLotNo EQ '') ) |
|
||||
or ( (OrigWfrQty NE '') and (NewWfrQty EQ '') ) or ( (OrigCustPartNo NE '') and (NewCustPartNo EQ '') ) |
|
||||
or ( (OrigSubPartNo NE '') and (NewSubPartNo EQ '') ) or (OrigNumActions GT NewNumActions) |
|
||||
or (OrigNumSlotNos GT NewNumSlotNos) or ( (OrigRxDtm NE '') and (NewRxDtm EQ '') ) |
|
||||
or ( (OrigRxBy NE '') and (NewRxBy EQ '') ) or ( (OrigRelDtm NE '') and (NewRelDtm EQ '') ) |
|
||||
or ( (OrigRelBy NE '') and (NewRelBy EQ '') ) or ( (OrigSubVendCd NE '') and (NewSubVendCd EQ '') ) |
|
||||
or ( (OrigCassShipQty NE '') and (NewCassShipQty EQ '') ) or ( (OrigShipShort NE '') and (NewShipShort EQ '') ) |
|
||||
or ( (OrigMuWaferFlag NE '') and (NewMuWaferFlag EQ '') ) ) then
|
||||
|
||||
Stack = Error_Services('GetStackTrace')
|
||||
Recipients = ''
|
||||
SentFrom = 'SYSTEM'
|
||||
Subject = 'WO_MAT_ACTIONS WRITE_PRE Blocked'
|
||||
Message = OConv(Datetime(), 'DT2/^H')
|
||||
Message<2> = 'Computer: ':@Station
|
||||
Message<3> = 'User: ':@User4
|
||||
Message<4> = 'WO_MAT key: ':Name
|
||||
Message<5> = 'Message: Write operation failed due to readonly field being cleared.'
|
||||
Message<6> = Stack
|
||||
Swap @FM with \0D0A\ in Message
|
||||
Swap @VM with ',' in Message
|
||||
AttachWindow = 'WO_MAT'
|
||||
AttachKey = Name
|
||||
SendToGroup = 'OI_SYSADMIN'
|
||||
|
||||
end
|
||||
Parms = Recipients:@RM:SentFrom:@RM:Subject:@RM:Message:@RM:AttachWindow:@RM:AttachKey:@RM:SendToGroup
|
||||
obj_Notes('Create',Parms)
|
||||
|
||||
OrigFileError = 104:': Write operation failed due to readonly field being cleared.'
|
||||
Status = 0
|
||||
Record = ''
|
||||
ActionFlow = ACTION_STOP$
|
||||
|
||||
end else
|
||||
|
||||
WaferQty = Record<WO_MAT_WAFER_QTY$>
|
||||
If ( (WaferQty LT 0) or (WaferQty GT 25) ) then
|
||||
// Erroneous wafer quantity save attempt. Fallback to default wafer quantity of 25.
|
||||
Record<WO_MAT_WAFER_QTY$> = 25
|
||||
SaveRecord = Record
|
||||
end
|
||||
|
||||
If ({REACTOR_TYPE} EQ 'GAN') and ({FQA_DTM} NE {CASS_FINAL_SIG_DTM}) then
|
||||
// Copy FQA date and datetime
|
||||
DTM = {CASS_FINAL_SIG_DTM}
|
||||
{FQA_DTM} = DTM
|
||||
Date = {CASS_FINAL_SIG_DTM}[1, 'F.']
|
||||
{FQA_DT} = Date
|
||||
SaveRecord = @Record
|
||||
end
|
||||
|
||||
// Sync up NCR signatures
|
||||
NewNCRList = Record<WO_MAT_NCR_KEYS$>
|
||||
OrigNCRList = OrigRecord<WO_MAT_NCR_KEYS$>
|
||||
NewNCRSigs = Record<WO_MAT_NCR_FINAL_SIG$>
|
||||
NewNCRSigDTMs = Record<WO_MAT_NCR_FINAL_SIG_DTM$>
|
||||
WaferQty = Record<WO_MAT_WAFER_QTY$>
|
||||
If ( (WaferQty LT 0) or (WaferQty GT 25) ) then
|
||||
// Erroneous wafer quantity save attempt. Fallback to default wafer quantity of 25.
|
||||
Record<WO_MAT_WAFER_QTY$> = 25
|
||||
SaveRecord = Record
|
||||
end
|
||||
|
||||
If ({REACTOR_TYPE} EQ 'GAN') and ({FQA_DTM} NE {CASS_FINAL_SIG_DTM}) then
|
||||
// Copy FQA date and datetime
|
||||
DTM = {CASS_FINAL_SIG_DTM}
|
||||
{FQA_DTM} = DTM
|
||||
Date = {CASS_FINAL_SIG_DTM}[1, 'F.']
|
||||
{FQA_DT} = Date
|
||||
SaveRecord = @Record
|
||||
end
|
||||
|
||||
// Sync up NCR signatures
|
||||
NewNCRList = Record<WO_MAT_NCR_KEYS$>
|
||||
OrigNCRList = OrigRecord<WO_MAT_NCR_KEYS$>
|
||||
NewNCRSigs = Record<WO_MAT_NCR_FINAL_SIG$>
|
||||
NewNCRSigDTMs = Record<WO_MAT_NCR_FINAL_SIG_DTM$>
|
||||
|
||||
// Check for deleted NCRs to remove final NCR signatures as needed.
|
||||
For each OrigNCRNo in OrigNCRList using @VM setting vPos
|
||||
NewNCRNo = NewNCRList<0, vPos>
|
||||
If NewNCRNo EQ '' then
|
||||
// An NCR has been deleted so we need to remove any final NCR signatures associate with it.
|
||||
NewNCRSigs<0, vPos> = ''
|
||||
NewNCRSigDTMs<0, vPos> = ''
|
||||
end
|
||||
Next OrigNCRNo
|
||||
|
||||
// Check for new NCRs to copy their final signature to the WO_MAT record.
|
||||
For each NewNCRNo in NewNCRList using @VM setting vPos
|
||||
// This is a new NCR, so copy the signature.
|
||||
NewNCRSigs<0, vPos> = Xlate('NCR', NewNCRNo, 'AUTH_SHIP_SIG', 'X')
|
||||
NewNCRSigDTMs<0, vPos> = Xlate('NCR', NewNCRNo, 'AUTH_SHIP_SIG_DTM', 'X')
|
||||
Next NewNCRNo
|
||||
|
||||
// Trim trailing @VMs to avoid WO_MAT CURR_STATUS from erroneously calculating an open NCR is present.
|
||||
NewNCRSigs = SRP_Array('Clean', NewNCRSigs, 'Trim', @VM)
|
||||
NewNCRSigDTMs = SRP_Array('Clean', NewNCRSigDTMs, 'Trim', @VM)
|
||||
Record<WO_MAT_NCR_FINAL_SIG$> = NewNCRSigs
|
||||
Record<WO_MAT_NCR_FINAL_SIG_DTM$> = NewNCRSigDTMs
|
||||
SaveRecord = Record
|
||||
|
||||
WONo = Field(Name, '*', 1)
|
||||
ReactType = Xlate('WO_LOG', WONo, 'REACT_TYPE', 'X')
|
||||
GaN = (ReactType EQ 'GAN')
|
||||
If GaN then
|
||||
// Sync QA signature with WO_MAT signature profile.
|
||||
OrigCassFinalSig = OrigRecord<WO_MAT_CASS_FINAL_SIG$>
|
||||
OrigCassFinalSigDTM = OrigRecord<WO_MAT_CASS_FINAL_SIG_DTM$>
|
||||
CassFinalSig = Record<WO_MAT_CASS_FINAL_SIG$>
|
||||
CassFinalSigDTM = Record<WO_MAT_CASS_FINAL_SIG_DTM$>
|
||||
|
||||
If ( (OrigCassFinalSig NE CassFinalSig) or (OrigCassFinalSigDTM NE CassFinalSigDTM) ) then
|
||||
WOMatStage = '1G_FQA'
|
||||
SigProf = Record<WO_MAT_SIG_PROFILE$>
|
||||
Sigs = Record<WO_MAT_SIGNATURE$>
|
||||
SigDTMs = Record<WO_MAT_SIG_DTM$>
|
||||
Locate WOMatStage in SigProf using @VM setting vPos then
|
||||
Sigs<0, vPos> = CassFinalSig
|
||||
SigDTMs<0, vPos> = CassFinalSigDTM
|
||||
Record<WO_MAT_SIGNATURE$> = Sigs
|
||||
Record<WO_MAT_SIG_DTM$> = SigDTMs
|
||||
SaveRecord = Record
|
||||
end
|
||||
end
|
||||
end
|
||||
|
||||
Begin Case
|
||||
Case {REACTOR_TYPE} EQ 'EPP'
|
||||
// EpiPro Silicon - Populate OUT_SLOT_NCR column in WO_MAT record
|
||||
NCRKeyChange = (OrigRecord<WO_MAT_NCR_KEYS$> NE Record<WO_MAT_NCR_KEYS$>)
|
||||
NCRSlotChange = (OrigRecord<WO_MAT_EPOS_NCR$> NE Record<WO_MAT_EPOS_NCR$>)
|
||||
WOMatSlotNCRs = {EPOS_NCR}
|
||||
NCRKeys = {NCR_KEYS}
|
||||
ChangeDetected = (NCRKeyChange or NCRSlotChange)
|
||||
If ChangeDetected then
|
||||
For each NCRKey in NCRKeys using @VM setting vPos
|
||||
OutSlotNos = Xlate('NCR', NCRKey, 'OUT_SLOT_NO', 'X')
|
||||
If OutSlotNos NE '' then
|
||||
For each SlotNo in OutSlotNos using @VM setting sPos
|
||||
WOMatSlotNCRs<0, SlotNo> = NCRKey
|
||||
Next SlotNo
|
||||
end
|
||||
Next NCRKey
|
||||
// Pad value marks if necessary
|
||||
NumSlots = DCount(WOMatSlotNCRs, @VM)
|
||||
If NumSlots LT 25 then WOMatSlotNCRs<0, 25> = ''
|
||||
Record<WO_MAT_EPOS_NCR$> = WOMatSlotNCRs
|
||||
SaveRecord = Record
|
||||
end
|
||||
Case {REACTOR_TYPE} EQ 'GAN'
|
||||
// Galiumn Nitride - Currently no issues with NCR keys getting erased, so nothing to do here.
|
||||
Null
|
||||
Case Otherwise$
|
||||
// Non-EpiPro Silicon - Populate SLOT_NCR column in WO_MAT record
|
||||
NCRKeyChange = (OrigRecord<WO_MAT_NCR_KEYS$> NE Record<WO_MAT_NCR_KEYS$>)
|
||||
NCRSlotChange = (OrigRecord<WO_MAT_SLOT_NCR$> NE Record<WO_MAT_SLOT_NCR$>)
|
||||
ChangeDetected = (NCRKeyChange or NCRSlotChange)
|
||||
If ChangeDetected then
|
||||
SlotNCRs = {SLOT_NCR}
|
||||
NCRKeys = {NCR_KEYS}
|
||||
For each NCRKey in NCRKeys using @VM setting vPos
|
||||
NCRSlotNos = Xlate('NCR', NCRKey, 'SLOT_NO', 'X')
|
||||
If NCRSlotNos NE '' then
|
||||
For each SlotNo in NCRSlotNos using @VM setting Dummy
|
||||
SlotNCRs<0, SlotNo> = NCRKey
|
||||
Next SlotNo
|
||||
end
|
||||
Next NCRKey
|
||||
Record<WO_MAT_SLOT_NCR$> = SlotNCRs
|
||||
SaveRecord = Record
|
||||
end
|
||||
NewMUFlag = Record<WO_MAT_MAKEUP_BOX$>
|
||||
OrigMUFlag = OrigRecord<WO_MAT_MAKEUP_BOX$>
|
||||
UnloadCheck = Signature_Services('GetStageSummary', WOMatKeyID, 'UNLOAD')<2>
|
||||
If (NewMUFlag EQ True$) AND (OrigMUFlag NE True$) then
|
||||
If UnloadCheck NE True$ then
|
||||
OrigFileError = 104:': Cassette ineligible to be converted to makeup wafer until unload is signed.'
|
||||
Status = 0
|
||||
Record = ''
|
||||
ActionFlow = ACTION_STOP$
|
||||
end
|
||||
end
|
||||
|
||||
End Case
|
||||
|
||||
TWChangeDetected = (OrigRecord<WO_MAT_SLOT_MET_NO$> NE Record<WO_MAT_SLOT_MET_NO$>)
|
||||
If TWChangeDetected then
|
||||
Begin Case
|
||||
Case {REACTOR_TYPE} EQ 'EPP'
|
||||
// EpiPro silicon -> build list of RDS_TEST keys and select those with TW_USE key(s).
|
||||
RDSNos = Xlate('WM_IN', {WMI_KEY}, 'RDS_NO', 'X')
|
||||
RDSNos = SRP_Array('Clean', RDSNos, 'TrimAndMakeUnique', @VM)
|
||||
If RDSNos NE '' then
|
||||
Query = 'SELECT RDS_TEST '
|
||||
For each RDSNo in RDSNos using @VM setting vPos
|
||||
If vPos EQ 1 then
|
||||
Query := 'WITH RDS_NO EQ ':RDSNo:' '
|
||||
end else
|
||||
Query := 'OR WITH RDS_NO EQ ':RDSNo:' '
|
||||
end
|
||||
Next RDSNo
|
||||
EOF = False$
|
||||
RecordCopy = Record
|
||||
RList(Query, TARGET_LATENTLIST$, '', '', '')
|
||||
Query = 'SELECT RDS_TEST WITH TW_USE_ID NE ""'
|
||||
RList(Query, TARGET_LATENTLIST$, '', '', '')
|
||||
RDSTestKeys = ''
|
||||
Loop
|
||||
ReadNext KeyID else EOF = True$
|
||||
Until EOF
|
||||
RDSTestKeys<0, -1> = KeyID
|
||||
Repeat
|
||||
TWUseKeys = Xlate('RDS_TEST', RDSTestKeys, 'TW_USE_ID', 'X')
|
||||
WaferIDs = Xlate('TW_USE', TWUseKeys, 'WAFER_ID', 'X')
|
||||
SlotMetNos = ''
|
||||
For each WaferID in WaferIDs using @VM setting vPos
|
||||
SlotNo = Field(WaferID, '*', 3)
|
||||
SlotMetNos<0, SlotNo> = TWUseKeys<0, vPos>
|
||||
Next WaferID
|
||||
Done = False$
|
||||
NumVMs = DCount(SlotMetNos, @VM)
|
||||
// Pad column with @VMs
|
||||
If NumVMs LT 25 then SlotMetNos<0, 25> = ''
|
||||
Record = RecordCopy
|
||||
Record<WO_MAT_SLOT_MET_NO$> = SlotMetNos
|
||||
SaveRecord = Record
|
||||
end
|
||||
Case {REACTOR_TYPE} EQ 'GAN'
|
||||
// Gallium nitride -> TW_USE records do not apply, so nothing to do.
|
||||
Null
|
||||
Case Otherwise$
|
||||
|
||||
// Non-EpiPro silicon -> lookup RDS_TEST record and interrogate it for TW_USE key(s).
|
||||
RDSNo = Record<WO_MAT_RDS_NO$>
|
||||
If RDSNo NE '' then
|
||||
Query = 'SELECT RDS_TEST WITH RDS_NO EQ ':RDSNo
|
||||
EOF = False$
|
||||
RecordCopy = Record
|
||||
RList(Query, TARGET_LATENTLIST$, '', '', '')
|
||||
Query = 'SELECT RDS_TEST WITH TW_USE_ID NE ""'
|
||||
RList(Query, TARGET_LATENTLIST$, '', '', '')
|
||||
RDSTestKeys = ''
|
||||
Loop
|
||||
ReadNext KeyID else EOF = True$
|
||||
Until EOF
|
||||
RDSTestKeys<0, -1> = KeyID
|
||||
Repeat
|
||||
TWUseKeys = Xlate('RDS_TEST', RDSTestKeys, 'TW_USE_ID', 'X')
|
||||
// Rebuild list
|
||||
SlotMetNos = ''
|
||||
For each TWUseKey in TWUseKeys using @VM setting tPos
|
||||
WaferIDs = Xlate('TW_USE', TWUseKey, 'WAFER_ID', 'X')
|
||||
For each WaferID in WaferIDs using @VM setting vPos
|
||||
SlotNo = Field(WaferID, '*', 3)
|
||||
SlotMetNos<0, SlotNo> = TWUseKey
|
||||
Next WaferID
|
||||
Next TWUseKey
|
||||
NumVMs = DCount(SlotMetNos, @VM)
|
||||
// Pad column with @VMs
|
||||
If NumVMs LT 25 then SlotMetNos<0, 25> = ''
|
||||
Record = RecordCopy
|
||||
Record<WO_MAT_SLOT_MET_NO$> = SlotMetNos
|
||||
SaveRecord = Record
|
||||
end
|
||||
|
||||
End Case
|
||||
end
|
||||
|
||||
// Verify slot list does not exceed 25
|
||||
NewSlotList = Record<WO_MAT_SLOT_NO$>
|
||||
NumSlots = DCount(NewSlotList, @VM)
|
||||
LastSlot = NewSlotList[-1, 'B':@VM]
|
||||
If ( (NumSlots GT 25) or (LastSlot GT 25) ) then
|
||||
|
||||
LogCount = Max(NumSlots, LastSlot)
|
||||
// Correct the slot column
|
||||
NewSlotList = ''
|
||||
For Slot = 1 to 25
|
||||
NewSlotList<0, Slot> = Slot
|
||||
Next Slot
|
||||
Record<WO_MAT_SLOT_NO$> = NewSlotList
|
||||
SaveRecord = Record
|
||||
|
||||
// Log the error
|
||||
Stack = RetStack()
|
||||
Swap @FM with CRLF$ in Stack
|
||||
LogData = ''
|
||||
LogData<1> = LoggingDTM
|
||||
LogData<2> = @User4
|
||||
LogData<3> = Name
|
||||
LogData<4> = LogCount
|
||||
LogData<5> = CRLF$:Stack
|
||||
Logging_Services('AppendLog', objSlotLog, LogData, @RM, @FM)
|
||||
|
||||
// Send internal LSL message to OI admins
|
||||
Recipients = XLATE('SEC_GROUPS', 'OI_ADMIN', 'USER', 'X')
|
||||
SentFrom = @USER4
|
||||
Subject = 'Slot count exceeds 25!'
|
||||
Message = 'WO_MAT key ':Name
|
||||
AttachWindow = 'WO_MAT'
|
||||
AttachKey = Name
|
||||
SendToGroup = ''
|
||||
Parms = Recipients:@RM:SentFrom:@RM:Subject:@RM:Message:@RM:AttachWindow:@RM:AttachKey:@RM:SendToGroup
|
||||
obj_Notes('Create',Parms)
|
||||
end
|
||||
|
||||
If {REACTOR_TYPE} EQ 'EPP' then
|
||||
WMKey = Field(Name, '*', 1):'*1*':Field(Name, '*', 2)
|
||||
// Only set fields if the records exist, otherwise WO_MAT curr status can be calculated incorrectly.
|
||||
If RowExists('WM_IN', WMKey) then Record<WO_MAT_WMI_KEY$> = WMKey
|
||||
If RowExists('WM_OUT', WMKey) then Record<WO_MAT_WMO_KEY$> = WMKey
|
||||
SaveRecord = Record
|
||||
end
|
||||
|
||||
SigProf = Record<WO_MAT_SIG_PROFILE$>
|
||||
Sigs = Record<WO_MAT_SIGNATURE$>
|
||||
SigDtms = Record<WO_MAT_SIG_DTM$>
|
||||
NumSteps = DCount(SigProf, @VM)
|
||||
Record<WO_MAT_SIGNATURE$> = Field(Sigs, @VM, 1, NumSteps)
|
||||
Record<WO_MAT_SIG_DTM$> = Field(SigDtms, @VM, 1, NumSteps)
|
||||
SaveRecord = Record
|
||||
|
||||
NewMUFlag = Record<WO_MAT_MAKEUP_BOX$>
|
||||
OrigMUFlag = OrigRecord<WO_MAT_MAKEUP_BOX$>
|
||||
If NewMUFlag NE OrigMUFlag then
|
||||
SAPBatchNo = Record<WO_MAT_SAP_BATCH_NO$>
|
||||
SAPTXDtm = Record<WO_MAT_SAP_TX_DTM$>
|
||||
AwaitingBatchNo = ( (SAPTXDtm NE '') and (SAPBatchNo EQ '') )
|
||||
FullBoxReject = (SAPBatchNo[-1, 1] = 'R')
|
||||
// Check for deleted NCRs to remove final NCR signatures as needed.
|
||||
For each OrigNCRNo in OrigNCRList using @VM setting vPos
|
||||
NewNCRNo = NewNCRList<0, vPos>
|
||||
If NewNCRNo EQ '' then
|
||||
// An NCR has been deleted so we need to remove any final NCR signatures associate with it.
|
||||
NewNCRSigs<0, vPos> = ''
|
||||
NewNCRSigDTMs<0, vPos> = ''
|
||||
end
|
||||
Next OrigNCRNo
|
||||
|
||||
// Check for new NCRs to copy their final signature to the WO_MAT record.
|
||||
For each NewNCRNo in NewNCRList using @VM setting vPos
|
||||
// This is a new NCR, so copy the signature.
|
||||
NewNCRSigs<0, vPos> = Xlate('NCR', NewNCRNo, 'AUTH_SHIP_SIG', 'X')
|
||||
NewNCRSigDTMs<0, vPos> = Xlate('NCR', NewNCRNo, 'AUTH_SHIP_SIG_DTM', 'X')
|
||||
Next NewNCRNo
|
||||
|
||||
// Trim trailing @VMs to avoid WO_MAT CURR_STATUS from erroneously calculating an open NCR is present.
|
||||
NewNCRSigs = SRP_Array('Clean', NewNCRSigs, 'Trim', @VM)
|
||||
NewNCRSigDTMs = SRP_Array('Clean', NewNCRSigDTMs, 'Trim', @VM)
|
||||
Record<WO_MAT_NCR_FINAL_SIG$> = NewNCRSigs
|
||||
Record<WO_MAT_NCR_FINAL_SIG_DTM$> = NewNCRSigDTMs
|
||||
SaveRecord = Record
|
||||
|
||||
WONo = Field(Name, '*', 1)
|
||||
ReactType = Xlate('WO_LOG', WONo, 'REACT_TYPE', 'X')
|
||||
GaN = (ReactType EQ 'GAN')
|
||||
If GaN then
|
||||
// Sync QA signature with WO_MAT signature profile.
|
||||
OrigCassFinalSig = OrigRecord<WO_MAT_CASS_FINAL_SIG$>
|
||||
OrigCassFinalSigDTM = OrigRecord<WO_MAT_CASS_FINAL_SIG_DTM$>
|
||||
CassFinalSig = Record<WO_MAT_CASS_FINAL_SIG$>
|
||||
CassFinalSigDTM = Record<WO_MAT_CASS_FINAL_SIG_DTM$>
|
||||
|
||||
If ( (OrigCassFinalSig NE CassFinalSig) or (OrigCassFinalSigDTM NE CassFinalSigDTM) ) then
|
||||
WOMatStage = '1G_FQA'
|
||||
SigProf = Record<WO_MAT_SIG_PROFILE$>
|
||||
Sigs = Record<WO_MAT_SIGNATURE$>
|
||||
SigDTMs = Record<WO_MAT_SIG_DTM$>
|
||||
Locate WOMatStage in SigProf using @VM setting vPos then
|
||||
Sigs<0, vPos> = CassFinalSig
|
||||
SigDTMs<0, vPos> = CassFinalSigDTM
|
||||
Record<WO_MAT_SIGNATURE$> = Sigs
|
||||
Record<WO_MAT_SIG_DTM$> = SigDTMs
|
||||
SaveRecord = Record
|
||||
end
|
||||
end
|
||||
end
|
||||
|
||||
Begin Case
|
||||
Case AwaitingBatchNo
|
||||
Error_Services('Add', 'Cassette ineligible to be converted as it is awaiting a batch number from SAP.')
|
||||
OrigFileError = 104:': Cassette ineligible to be converted as it is awaiting a batch number from SAP.'
|
||||
Status = 0
|
||||
Record = ''
|
||||
ActionFlow = ACTION_STOP$
|
||||
Case FullBoxReject
|
||||
Error_Services('Add', 'Cassette ineligible to be converted as it is a full box reject.')
|
||||
OrigFileError = 104:': Cassette ineligible to be converted as it is a full box reject.'
|
||||
Status = 0
|
||||
Record = ''
|
||||
ActionFlow = ACTION_STOP$
|
||||
Case Otherwise$
|
||||
Case {REACTOR_TYPE} EQ 'EPP'
|
||||
// EpiPro Silicon - Populate OUT_SLOT_NCR column in WO_MAT record
|
||||
NCRKeyChange = (OrigRecord<WO_MAT_NCR_KEYS$> NE Record<WO_MAT_NCR_KEYS$>)
|
||||
NCRSlotChange = (OrigRecord<WO_MAT_EPOS_NCR$> NE Record<WO_MAT_EPOS_NCR$>)
|
||||
WOMatSlotNCRs = {EPOS_NCR}
|
||||
NCRKeys = {NCR_KEYS}
|
||||
ChangeDetected = (NCRKeyChange or NCRSlotChange)
|
||||
If ChangeDetected then
|
||||
For each NCRKey in NCRKeys using @VM setting vPos
|
||||
OutSlotNos = Xlate('NCR', NCRKey, 'OUT_SLOT_NO', 'X')
|
||||
If OutSlotNos NE '' then
|
||||
For each SlotNo in OutSlotNos using @VM setting sPos
|
||||
WOMatSlotNCRs<0, SlotNo> = NCRKey
|
||||
Next SlotNo
|
||||
end
|
||||
Next NCRKey
|
||||
// Pad value marks if necessary
|
||||
NumSlots = DCount(WOMatSlotNCRs, @VM)
|
||||
If NumSlots LT 25 then WOMatSlotNCRs<0, 25> = ''
|
||||
Record<WO_MAT_EPOS_NCR$> = WOMatSlotNCRs
|
||||
SaveRecord = Record
|
||||
end
|
||||
Case {REACTOR_TYPE} EQ 'GAN'
|
||||
// Galiumn Nitride - Currently no issues with NCR keys getting erased, so nothing to do here.
|
||||
Null
|
||||
Case Otherwise$
|
||||
// Non-EpiPro Silicon - Populate SLOT_NCR column in WO_MAT record
|
||||
NCRKeyChange = (OrigRecord<WO_MAT_NCR_KEYS$> NE Record<WO_MAT_NCR_KEYS$>)
|
||||
NCRSlotChange = (OrigRecord<WO_MAT_SLOT_NCR$> NE Record<WO_MAT_SLOT_NCR$>)
|
||||
ChangeDetected = (NCRKeyChange or NCRSlotChange)
|
||||
If ChangeDetected then
|
||||
SlotNCRs = {SLOT_NCR}
|
||||
NCRKeys = {NCR_KEYS}
|
||||
For each NCRKey in NCRKeys using @VM setting vPos
|
||||
NCRSlotNos = Xlate('NCR', NCRKey, 'SLOT_NO', 'X')
|
||||
If NCRSlotNos NE '' then
|
||||
For each SlotNo in NCRSlotNos using @VM setting Dummy
|
||||
SlotNCRs<0, SlotNo> = NCRKey
|
||||
Next SlotNo
|
||||
end
|
||||
Next NCRKey
|
||||
Record<WO_MAT_SLOT_NCR$> = SlotNCRs
|
||||
SaveRecord = Record
|
||||
end
|
||||
NewMUFlag = Record<WO_MAT_MAKEUP_BOX$>
|
||||
OrigMUFlag = OrigRecord<WO_MAT_MAKEUP_BOX$>
|
||||
UnloadCheck = Signature_Services('GetStageSummary', WOMatKeyID, 'UNLOAD')<2>
|
||||
If (NewMUFlag EQ True$) AND (OrigMUFlag NE True$) then
|
||||
If UnloadCheck NE True$ then
|
||||
OrigFileError = 104:': Cassette ineligible to be converted to makeup wafer until unload is signed.'
|
||||
Status = 0
|
||||
Record = ''
|
||||
ActionFlow = ACTION_STOP$
|
||||
end
|
||||
end
|
||||
|
||||
End Case
|
||||
|
||||
TWChangeDetected = (OrigRecord<WO_MAT_SLOT_MET_NO$> NE Record<WO_MAT_SLOT_MET_NO$>)
|
||||
If TWChangeDetected then
|
||||
Begin Case
|
||||
Case {REACTOR_TYPE} EQ 'EPP'
|
||||
// EpiPro silicon -> build list of RDS_TEST keys and select those with TW_USE key(s).
|
||||
RDSNos = Xlate('WM_IN', {WMI_KEY}, 'RDS_NO', 'X')
|
||||
RDSNos = SRP_Array('Clean', RDSNos, 'TrimAndMakeUnique', @VM)
|
||||
If RDSNos NE '' then
|
||||
Query = 'SELECT RDS_TEST '
|
||||
For each RDSNo in RDSNos using @VM setting vPos
|
||||
If vPos EQ 1 then
|
||||
Query := 'WITH RDS_NO EQ ':RDSNo:' '
|
||||
end else
|
||||
Query := 'OR WITH RDS_NO EQ ':RDSNo:' '
|
||||
end
|
||||
Next RDSNo
|
||||
EOF = False$
|
||||
RecordCopy = Record
|
||||
RList(Query, TARGET_LATENTLIST$, '', '', '')
|
||||
Query = 'SELECT RDS_TEST WITH TW_USE_ID NE ""'
|
||||
RList(Query, TARGET_LATENTLIST$, '', '', '')
|
||||
RDSTestKeys = ''
|
||||
Loop
|
||||
ReadNext KeyID else EOF = True$
|
||||
Until EOF
|
||||
RDSTestKeys<0, -1> = KeyID
|
||||
Repeat
|
||||
TWUseKeys = Xlate('RDS_TEST', RDSTestKeys, 'TW_USE_ID', 'X')
|
||||
WaferIDs = Xlate('TW_USE', TWUseKeys, 'WAFER_ID', 'X')
|
||||
SlotMetNos = ''
|
||||
For each WaferID in WaferIDs using @VM setting vPos
|
||||
SlotNo = Field(WaferID, '*', 3)
|
||||
SlotMetNos<0, SlotNo> = TWUseKeys<0, vPos>
|
||||
Next WaferID
|
||||
Done = False$
|
||||
NumVMs = DCount(SlotMetNos, @VM)
|
||||
// Pad column with @VMs
|
||||
If NumVMs LT 25 then SlotMetNos<0, 25> = ''
|
||||
Record = RecordCopy
|
||||
Record<WO_MAT_SLOT_MET_NO$> = SlotMetNos
|
||||
SaveRecord = Record
|
||||
end
|
||||
Case {REACTOR_TYPE} EQ 'GAN'
|
||||
// Gallium nitride -> TW_USE records do not apply, so nothing to do.
|
||||
Null
|
||||
Case Otherwise$
|
||||
|
||||
// Non-EpiPro silicon -> lookup RDS_TEST record and interrogate it for TW_USE key(s).
|
||||
RDSNo = Record<WO_MAT_RDS_NO$>
|
||||
If RDSNo NE '' then
|
||||
Query = 'SELECT RDS_TEST WITH RDS_NO EQ ':RDSNo
|
||||
EOF = False$
|
||||
RecordCopy = Record
|
||||
RList(Query, TARGET_LATENTLIST$, '', '', '')
|
||||
Query = 'SELECT RDS_TEST WITH TW_USE_ID NE ""'
|
||||
RList(Query, TARGET_LATENTLIST$, '', '', '')
|
||||
RDSTestKeys = ''
|
||||
Loop
|
||||
ReadNext KeyID else EOF = True$
|
||||
Until EOF
|
||||
RDSTestKeys<0, -1> = KeyID
|
||||
Repeat
|
||||
TWUseKeys = Xlate('RDS_TEST', RDSTestKeys, 'TW_USE_ID', 'X')
|
||||
// Rebuild list
|
||||
SlotMetNos = ''
|
||||
For each TWUseKey in TWUseKeys using @VM setting tPos
|
||||
WaferIDs = Xlate('TW_USE', TWUseKey, 'WAFER_ID', 'X')
|
||||
For each WaferID in WaferIDs using @VM setting vPos
|
||||
SlotNo = Field(WaferID, '*', 3)
|
||||
SlotMetNos<0, SlotNo> = TWUseKey
|
||||
Next WaferID
|
||||
Next TWUseKey
|
||||
NumVMs = DCount(SlotMetNos, @VM)
|
||||
// Pad column with @VMs
|
||||
If NumVMs LT 25 then SlotMetNos<0, 25> = ''
|
||||
Record = RecordCopy
|
||||
Record<WO_MAT_SLOT_MET_NO$> = SlotMetNos
|
||||
SaveRecord = Record
|
||||
end
|
||||
|
||||
End Case
|
||||
end
|
||||
|
||||
// Verify slot list does not exceed 25
|
||||
NewSlotList = Record<WO_MAT_SLOT_NO$>
|
||||
NumSlots = DCount(NewSlotList, @VM)
|
||||
LastSlot = NewSlotList[-1, 'B':@VM]
|
||||
If ( (NumSlots GT 25) or (LastSlot GT 25) ) then
|
||||
|
||||
LogCount = Max(NumSlots, LastSlot)
|
||||
// Correct the slot column
|
||||
NewSlotList = ''
|
||||
For Slot = 1 to 25
|
||||
NewSlotList<0, Slot> = Slot
|
||||
Next Slot
|
||||
Record<WO_MAT_SLOT_NO$> = NewSlotList
|
||||
SaveRecord = Record
|
||||
|
||||
// Log the error
|
||||
Stack = RetStack()
|
||||
Swap @FM with CRLF$ in Stack
|
||||
LogData = ''
|
||||
LogData<1> = LoggingDTM
|
||||
LogData<2> = @User4
|
||||
LogData<3> = Name
|
||||
LogData<4> = LogCount
|
||||
LogData<5> = CRLF$:Stack
|
||||
Logging_Services('AppendLog', objSlotLog, LogData, @RM, @FM)
|
||||
|
||||
// Send internal LSL message to OI admins
|
||||
Recipients = XLATE('SEC_GROUPS', 'OI_ADMIN', 'USER', 'X')
|
||||
SentFrom = @USER4
|
||||
Subject = 'Slot count exceeds 25!'
|
||||
Message = 'WO_MAT key ':Name
|
||||
AttachWindow = 'WO_MAT'
|
||||
AttachKey = Name
|
||||
SendToGroup = ''
|
||||
Parms = Recipients:@RM:SentFrom:@RM:Subject:@RM:Message:@RM:AttachWindow:@RM:AttachKey:@RM:SendToGroup
|
||||
obj_Notes('Create',Parms)
|
||||
end
|
||||
|
||||
If {REACTOR_TYPE} EQ 'EPP' then
|
||||
WMKey = Field(Name, '*', 1):'*1*':Field(Name, '*', 2)
|
||||
// Only set fields if the records exist, otherwise WO_MAT curr status can be calculated incorrectly.
|
||||
If RowExists('WM_IN', WMKey) then Record<WO_MAT_WMI_KEY$> = WMKey
|
||||
If RowExists('WM_OUT', WMKey) then Record<WO_MAT_WMO_KEY$> = WMKey
|
||||
SaveRecord = Record
|
||||
end
|
||||
|
||||
SigProf = Record<WO_MAT_SIG_PROFILE$>
|
||||
Sigs = Record<WO_MAT_SIGNATURE$>
|
||||
SigDtms = Record<WO_MAT_SIG_DTM$>
|
||||
NumSteps = DCount(SigProf, @VM)
|
||||
Record<WO_MAT_SIGNATURE$> = Field(Sigs, @VM, 1, NumSteps)
|
||||
Record<WO_MAT_SIG_DTM$> = Field(SigDtms, @VM, 1, NumSteps)
|
||||
SaveRecord = Record
|
||||
|
||||
NewMUFlag = Record<WO_MAT_MAKEUP_BOX$>
|
||||
OrigMUFlag = OrigRecord<WO_MAT_MAKEUP_BOX$>
|
||||
If NewMUFlag NE OrigMUFlag then
|
||||
SAPBatchNo = Record<WO_MAT_SAP_BATCH_NO$>
|
||||
SAPTXDtm = Record<WO_MAT_SAP_TX_DTM$>
|
||||
AwaitingBatchNo = ( (SAPTXDtm NE '') and (SAPBatchNo EQ '') )
|
||||
FullBoxReject = (SAPBatchNo[-1, 1] = 'R')
|
||||
Begin Case
|
||||
Case AwaitingBatchNo
|
||||
Error_Services('Add', 'Cassette ineligible to be converted as it is awaiting a batch number from SAP.')
|
||||
OrigFileError = 104:': Cassette ineligible to be converted as it is awaiting a batch number from SAP.'
|
||||
Status = 0
|
||||
Record = ''
|
||||
ActionFlow = ACTION_STOP$
|
||||
Case FullBoxReject
|
||||
Error_Services('Add', 'Cassette ineligible to be converted as it is a full box reject.')
|
||||
OrigFileError = 104:': Cassette ineligible to be converted as it is a full box reject.'
|
||||
Status = 0
|
||||
Record = ''
|
||||
ActionFlow = ACTION_STOP$
|
||||
Case Otherwise$
|
||||
Null
|
||||
End Case
|
||||
end
|
||||
|
||||
end
|
||||
|
||||
|
||||
return
|
||||
|
||||
@ -902,3 +952,4 @@ Restore_System_Variables:
|
||||
|
||||
return
|
||||
|
||||
|
||||
|
Reference in New Issue
Block a user