restoring HgCV pattern on the control plan

This commit is contained in:
Infineon\StieberD
2025-08-28 11:14:18 -07:00
committed by Stieber Daniel (CSC FI SPS MESLEO)
parent c30bb96972
commit 2fa985137f

View File

@ -450,11 +450,7 @@ Main:
lsData<I,7> = PropRec<PRS_PROP_TOOL$> lsData<I,7> = PropRec<PRS_PROP_TOOL$>
lsData<I,8> = PropRec<PRS_PROP_MET_WFR_TYPE$> lsData<I,8> = PropRec<PRS_PROP_MET_WFR_TYPE$>
lsData<I,9> = PropRec<PRS_PROP_MET_RECIPE$> lsData<I,9> = PropRec<PRS_PROP_MET_RECIPE$>
If (PropRec<PRS_PROP_TOOL$> _NEC 'HgCV') then lsData<I,10> = PropRec<PRS_PROP_MET_RECIPE_PATTERN$>
lsData<I,10> = PropRec<PRS_PROP_MET_RECIPE_PATTERN$>
end else
lsData<I,10> = ''
end
lsData<I,11> = PropRec<PRS_PROP_MET_INTERVAL$> lsData<I,11> = PropRec<PRS_PROP_MET_INTERVAL$>
lsData<I,12> = PropRec<PRS_PROP_PROVEIN_WFR_TYPE$> lsData<I,12> = PropRec<PRS_PROP_PROVEIN_WFR_TYPE$>
@ -468,11 +464,7 @@ Main:
lsData<I,7> = lsData<I,7>:CRLF$:PropRec<PRS_PROP_TOOL$> lsData<I,7> = lsData<I,7>:CRLF$:PropRec<PRS_PROP_TOOL$>
lsData<I,8> = lsData<I,8>:CRLF$:PropRec<PRS_PROP_MET_WFR_TYPE$> lsData<I,8> = lsData<I,8>:CRLF$:PropRec<PRS_PROP_MET_WFR_TYPE$>
lsData<I,9> = lsData<I,9>:CRLF$:PropRec<PRS_PROP_MET_RECIPE$> lsData<I,9> = lsData<I,9>:CRLF$:PropRec<PRS_PROP_MET_RECIPE$>
If (PropRec<PRS_PROP_TOOL$> _NEC 'HgCV') then lsData<I,10> = lsData<I,10>:CRLF$:PropRec<PRS_PROP_MET_RECIPE_PATTERN$>
lsData<I,10> = lsData<I,10>:CRLF$:PropRec<PRS_PROP_MET_RECIPE_PATTERN$>
end else
lsData<I,10> = lsData<I,10>:CRLF$
end
lsData<I,11> = lsData<I,11>:CRLF$:PropRec<PRS_PROP_MET_INTERVAL$> lsData<I,11> = lsData<I,11>:CRLF$:PropRec<PRS_PROP_MET_INTERVAL$>
lsData<I,12> = lsData<I,12>:CRLF$:PropRec<PRS_PROP_PROVEIN_WFR_TYPE$> lsData<I,12> = lsData<I,12>:CRLF$:PropRec<PRS_PROP_PROVEIN_WFR_TYPE$>
@ -840,14 +832,10 @@ Main:
end else end else
colData<StepNo,STEP_PRODUCT$> = CHAR(185):obj_Met_Prop('GetPropDesc',StageRec<PRS_STAGE_MET_PROP$,M>) colData<StepNo,STEP_PRODUCT$> = CHAR(185):obj_Met_Prop('GetPropDesc',StageRec<PRS_STAGE_MET_PROP$,M>)
end end
If (StageRec<PRS_STAGE_MET_TOOL_CLASS$,M> _NEC 'HgCV') then colData<StepNo,STEP_RECIPE$> = StageRec<PRS_STAGE_MET_RECIPE$,M>:CRLF$:StageRec<PRS_STAGE_MET_RECIPE_PATTERN$,M>
colData<StepNo,STEP_RECIPE$> = StageRec<PRS_STAGE_MET_RECIPE$,M>:CRLF$:StageRec<PRS_STAGE_MET_RECIPE_PATTERN$,M> colData<StepNo,STEP_SPEC_TOL$> = StageRec<PRS_STAGE_MET_MIN$,M>:' - ':StageRec<PRS_STAGE_MET_MAX$,M>:' ':obj_Met_Prop('GetUnitsDesc',StageRec<PRS_STAGE_MET_PROP$,M>)
end else colData<StepNo,STEP_SIZE$> = StageRec<PRS_STAGE_MET_WFR_QTY$,M>
colData<StepNo,STEP_RECIPE$> = StageRec<PRS_STAGE_MET_RECIPE$,M> colData<StepNo,STEP_FREQ$> = StageRec<PRS_STAGE_MET_INTERVAL$,M>
end
colData<StepNo,STEP_SPEC_TOL$> = StageRec<PRS_STAGE_MET_MIN$,M>:' - ':StageRec<PRS_STAGE_MET_MAX$,M>:' ':obj_Met_Prop('GetUnitsDesc',StageRec<PRS_STAGE_MET_PROP$,M>)
colData<StepNo,STEP_SIZE$> = StageRec<PRS_STAGE_MET_WFR_QTY$,M>
colData<StepNo,STEP_FREQ$> = StageRec<PRS_STAGE_MET_INTERVAL$,M>
if processName EQ 'FQA' then if processName EQ 'FQA' then
colData<StepNo,STEP_CTRL_METHOD$> = "WI" colData<StepNo,STEP_CTRL_METHOD$> = "WI"