--- type: note created: 2023-07-08T02:49:15.271Z updated: 2023-07-08T03:55:16.399Z --- # Restart IFX Hosted N Port # Navigate to https://goto.infineon.com/ucportal and under SelfCP - Auto CF call EAF/EDA, Metrology Viewer, Infinity QS SPC number From mestsa003.infineon.com(eaf-dev.mes.infineon.com) using your normal or MES account open the following application "C:\Program Files\NPortAdminSuite\bin\npadmer.exe" if not found in start menu (NPort Administrator) Select Port Monitor - Right click anywhere in the right pane - select load configuration com port - press go button from top ribbon Look at entries starting with IP 10.95.192.\* for conn status not Connected and then - Find entry with not connected under cond status - Find matching EAF CI instance and verifying connection name "PCLDevice" with matching IP in connection settings example shown below - Stop CI in EAF - Using browser (Edge) navigate to http matching ip (this will bring up Moxa website like a home router) password is in shared KeePass - Restart nPort device by using website - Start EAF again - If not on phone with user wait for data for about five minutes if nothing repeat one more time - If still no data stop EAF like above - Call lead and have them power cycle the nPort - Start EAF and check for data in file share \\messv02ecc1.ec.local\EC_Characterization_Si\RawData base on folder date modified ![Alt Text](_Restart-IFX-hosted-nPort/image-1.png) ![Alt Text](_Restart-IFX-hosted-nPort/image-2.png) ![Alt Text](_Restart-IFX-hosted-nPort/image-3.png)