Front Matter
H1 Rename for other application
This commit is contained in:
32
Applications/EAF/restart-ifx-hosted-nport.md
Normal file
32
Applications/EAF/restart-ifx-hosted-nport.md
Normal file
@ -0,0 +1,32 @@
|
||||
---
|
||||
type: note
|
||||
created: 2023-07-08T02:49:15.271Z
|
||||
updated: 2023-07-08T03:55:16.399Z
|
||||
---
|
||||
|
||||
# Restart IFX Hosted N Port
|
||||
|
||||
# Navigate to https://goto.infineon.com/ucportal and under SelfCP - Auto CF call EAF/EDA, Metrology Viewer, Infinity QS SPC number
|
||||
|
||||
From mestsa003.infineon.com(eaf-dev.mes.infineon.com) using your normal or MES account open the following application
|
||||
|
||||
"C:\Program Files\NPortAdminSuite\bin\npadmer.exe" if not found in start menu (NPort Administrator)
|
||||
|
||||
Select Port Monitor - Right click anywhere in the right pane - select load configuration com port - press go button from top ribbon
|
||||
|
||||
Look at entries starting with IP 10.95.192.\* for conn status not Connected and then
|
||||
|
||||
- Find entry with not connected under cond status
|
||||
- Find matching EAF CI instance and verifying connection name "PCLDevice" with matching IP in connection settings example shown below
|
||||
- Stop CI in EAF
|
||||
- Using browser (Edge) navigate to http matching ip (this will bring up Moxa website like a home router) password is in shared KeePass
|
||||
- Restart nPort device by using website
|
||||
- Start EAF again
|
||||
- If not on phone with user wait for data for about five minutes if nothing repeat one more time
|
||||
- If still no data stop EAF like above
|
||||
- Call lead and have them power cycle the nPort
|
||||
- Start EAF and check for data in file share \\messv02ecc1.ec.local\EC_Characterization_Si\RawData base on folder date modified
|
||||
|
||||

|
||||

|
||||

|
Reference in New Issue